Esp Safety 100-0016-al-1-1 | Ir3 | Flame Detectors | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

ESP SAFETY   100-0016-AL-1-1

SKU# (4720)



ESP SAFETY 100-0016-AL-1-1

DETECTORS / FLAME DETECTORS
IR3

$1,888.20  [5 Weeks]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
ESP Safety IPES-IR3 Infrared Flame Detector for detection of combustible vapors gases fires. Sends an alarm only when data from 3 different IR wavelengths detects a flame. RS-485, Modbus RTU, 4-20 mA and relay outputs. Tri-Color status LED. Explosion-proof Housing. IP66. Designed for Class I, Div 1, Group B, C & D. ATEX certified, SIL3 Rated. Includes protective visor, stainless steel mounting bracket and hardware.

4-20 mA   RELAYS   ATEX   DIV 1   SIL3   MODBUS

100-0016-AL-1-1   
1,888.20

Enclosure material

   5 Weeks  ]
2 Variants of base SKU

The state-of-the-art multi-spectral infrared technology of ESP Safety’s Model IPES-IR3 Flame Detector affords the highest sensitivity in detecting flames from combustible vapors gases within a wide field of view. It is preferred where UV in other detectors may be a problem with false signal triggers.

IPES-IR3’s advanced detection technology ensures rapid flame recognition and alarm signaling. In addition, IPES-IR3’s selective, multi-spectral technology virtually eliminates false alarms. It ignores false triggers from sources such as direct or indirect sunlight, arc welder flash, resistive heaters, fluorescent, halogen, and incandescent light.

IPES-IR3 sends an alarm only when data from three different IR wavelengths agree that a flame or fire is present in the field of view. Upon confirmation of flame or fire, the IPES-IR3 transfers alarm signals to receiving control devices located in control and operations rooms and to fire alarms and burglar/fire alarm systems. While operating, the IPES-IR3 transmits detector-status information via:

  • 4-20 mA analog output
  • A standard RS-485 communication channel under protocol Modbus RTU
  • Relay outputs

The IPES-IR3 Flame Detector is constructed with an explosion-proof housing for use in hazardous (classified) locations. It meets the certifications and requirements of of FM Class I, Division 1, Group B, C & D, T4; ATEX and SIL3.

Applications
  • Drilling and production platforms
  • Shipping tankers, freighters, and other vessels
  • Fuel loading facilities
  • Refineries, bulk terminals, and tank farms
  • LNG/LPG processing and storage facilities
  • Compressor stations and pipeline facilities
  • Petrochemical, paint, and fertilizer plants
  • Power plants and gas turbine facilities
  • Transportation facilities (airports and subways)
  • Oil and gas fired boilers / furnaces
  • Aircraft hangars
Features and benefits
  • Multi-spectral IR detection provides the highest level of flame and fire sensitivity.
  • Multi-spectral IR detection provides optimal rejection of false alarms.
  • Power-on self-test and frequent sensor self-test ensure system integrity and correct operation.
  • Heated optics, secondary heater function helps to prevent condensation problems.
  • Explosion-proof package allows for hazardous environment operation.
  • Tri-color status LED on the device is easily viewable for a visual report of the device’s operating status.
  • Continuous monitoring of the optical path for obstruction or reduced transmission affords maximum reliability.
  • Power consumption of <3W means low power costs, protection against surges.
  • Digital, analog and relay outputs provide reliable status information across a range of communication formats.
  • Industry standard for remote alarm and fault indication ensure reliability and consistency.
  • Extended detection range provides a greater area of protection.
  • 5-year warranty – long, reliable product life; low cost to operate over time.

Specifications
Electrical Characteristics
Voltage18 to 32 VDC
Power<2 W, standby
<3 W, during alarm
<7.5 W, with heater on maximum
Analog Outputs4-20 mA
Analog signal: Current Fault signal: 2 mA ± 0.1 mA
Ready signal: 4 mA ± 0.1 mA
Fire signal: 18 mA ± 0.1 mA
Test Mode: 8 mA ± 0.1 mA
Digital OutputsRS 485, Modbus RTU, Profibus
Relay ContactFire Alarm:
- normally open relay
- closed on fire detection
- latching / non-latching
Fault:
- normally closed relay
- open on fault detection
Operating Temperature-40°F to +185°F
(-40°C to +85°C)
Extended Operating Temperature (By Request)-75°F to +255°F (-60°C to +125°C)
Storage temperature-76°F to +185°F
(-60°C to +85°C)
HumidityUp to 95 % Relative humidity (withstands up to 100% RH for short periods)
Wiring14 AWG (2.08 mm) or 16 AWG (1.31 mm)
Shielded cable is recommended
SIL RatingSIL 3
Ingress ProtectionIP66
Mechanical Characteristics
Material316 Stainless Steel
Cable Entry3/4” NPT
Weight11 lbs (5.0 kg)
Warranty5 years
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)90318099

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    4 Items found.
VORTEX-SHIELD
(7184)

ESP SAFETY  VORTEX-SHIELD

ESP Safety Vortex Air Shield for keeping airborne particulates away from the optical window of IPES Flame Detectors. Dual air flow assembly with two rings of 16 air jets for creating two Air-Barriers preventing obstructions in extreme applications. Anodized Aluminum.



$332.51 
120-0007
(4721)

ESP SAFETY  120-0007

ESP Safety Portable ITES-Dual Test Lamp flame simulator to do functional testing for all ESP IPES Detectors(UV, IR/UV, IR3). Generates directed modulated radiation to signal a flame response. Explosion proof.



$1,162.40 
100-0003-01
(4719)

ESP SAFETY  100-0003-01

ESP Safety IPES-IR/UV Infrared/Ultraviolet Flame Detector for detection of oil and petrochemical product fires. 4.2 to 4.6 microns (infrared) and 180 to 250 nanometers (ultraviolet) ranges. 90 degree field of view. RS-485, Modbus RTU, 4-20 mA and relay outputs. Color status LED. Explosion-proof Housing. Designed for Class I, Div 1, Group B, C & D. ATEX certified, SIL3 Rated. Includes protective visor, stainless steel mounting bracket and hardware.

Configure

$1,413.00 
100-0003-01
(4718)

ESP SAFETY  100-0003-01

ESP Safety IPES-UV Ultraviolet Flame Detector of hydrogen, metal fire and pyrophoric material fires. 180 to 250 nanometers range. 90 degree field of view. RS-485, Modbus RTU, 4-20 mA and relay outputs. Color status LED. Explosion-proof. Designed for Class I, Div 1, Group B, C & D. ATEX certified, SIL3 Rated. Includes protective visor, stainless steel mounting bracket and hardware.

Configure

$1,413.00 
> IR3 :    10 Items found.
116-5861-011.4310
(7231)

AUTRONICA  116-5861-011.4310

Autronica AutroFlame X33AF Multispectrum Triple Infrared (IR3) Flame Detector for multiple hydrocarbon fuels. Explosion/flame proof. Includes fire alarm, fault and auxiliary relays, isolated 0-20 mA output model with optional HART communication. 24 VDC. SIL2, FM and ATEX certified for use in Class I, Divi 1 and Div 2.

20/20MPI-R
(2940)

SPECTREX  20/20MPI-R

SPECTREX Sharp Eye 20/20MPI IR3 Flame Detector for indoor applications. Low cost, High Performance, High Reliability and Long Distance for hydrocarbon-based fuel and gas fires. Polycarbonate housing. 2 Relays (Alarm and Fault) OR 0-20mA output and compatible with RS-485 Modbus. IP55. Includes Tilt mount and protective cover. Automatic and Manual Built-In-Test (BIT), indoor use. Available Approvals: FM3260 and EN54-10 (Pending).

Configure

$2,302.60 
FSL100-IR3
(6772)

HONEYWELL  FSL100-IR3

Honeywell FSL100-IR3 Flame Detector for robust, fast, and reliable detection of liquid hydrocarbon and dirty fires in indoor/outdoor environments and potentially explosive atmospheres. Relay and mA outputs. GRP housing. EN54-10 and FM3260 approvals. IP65.

Configure

$2,403.53 
20/20MI-11-S-F
(2945)

SPECTREX  20/20MI-11-S-F

SPECTREX Sharp Eye 20/20MI Mini Triple IR (IR3) Flame Detector for detection of gasoline, n-heptane, diesel, JP5 jet fuel, kerosene, ethanol, IPA, methanol, methane, LPG propane, hydrogen, polypropilene, hydroxy fuels, hydrazine, paint spray and paper fires. Low cost, stainless steel enclosure, compact and lightweight. Highly resistant to harsh environments, immune to false alarms and designed for OUTDOOR or INDOOR applications. 2 Relays (Alarm and Fault-not with Ex), 0-20mA (sink or source), automatic and Manual Built-In-Test (BIT) and compatible with RS-485 Modbus. Stainless steel housing. Available Approvals: FM (Functionality, No Ex)

Configure

$3,174.99 
X3301A4N23SB2
(7000)

DET-TRONICS  X3301A4N23SB2

Det-tronics X3301 Multispectrum Triple IR Flame Detector for detection of hydrocarbon fuels. Explosion proof. Indoor and outdoor applications. Includes fire alarm, fault and auxiliary relays and isolated 0–20 mA output. Optional HART. FM, ATEX and SIL2 Approvals.

FS24X-911-21-5
(1989)

HONEYWELL  FS24X-911-21-5

Honeywell Fire Sentry FS24X Series 911 Multi-Spectrum QuadBand Triple IR (IR3) Fire and Flame Detector for hydrocarbon and non-hydrocarbon fires in all enviromental conditions. 90 Degrees field of view. With WireBand Technology, RS-485 ModBus communication and non-isolated 4-20 mA analog output. Includes alarm, fault and fire verification relays. FM, ATEX, CE and INMETRO mark approvals

Configure

$4,371.15 
DF-TV7-XTA0-0XH-00
(6404)

SIMTRONICS  DF-TV7-XTA0-0XH-00

Simtronics DF-TV7-T Triple Infrared (IR3) Flame Detector for Hydrocarbon fires. Relay, 4-20 mA, 0-22mA and Hart outputs. Configuration with Wireless handheld (TLU600) or via HART. IP66. Certified by SIL3, ATEX, IECEx and CE DPC.

40/40C-I-6-41-AC-N-7
(6857)

SPECTREX  40/40C-I-6-41-AC-N-7

SPECTREX SharpEye 40/40C-I Multispectrum Quad-Sense Flame Detector with Triple Infrared IR3 technology. Detects hydrocarbon fires at long distances with superior immunity to false alarms. 24 Vdc. Includes HART capability, Automatic Built-In-Test (BIT), 3 Relays for alarm, fault and auxiliary and RS-485 Modbus outputs. Heavy duty copper free aluminum housing. IP66 and IP68. NEMA 250 6P. ATEX, IECEx, FM, CSA and SIL3 Approved. Capable for Class I Div 1 & 2.

Configure

$4,548.42 
40/40D-I-6-31-AC-N-7
(6883)

SPECTREX  40/40D-I-6-31-AC-N-7

SPECTREX SharpEye 40/40D-I Ultra Fast Multispectrum Quad-Sense Flame Detector with IR3 Triple Infrared technology. Detects hydrocarbon fires at long distances with superior immunity to false alarms. 24 Vdc. Includes HART capability, Automatic Built-In-Test (BIT), 3 Relays for alarm, fault and auxiliary and RS-485 Modbus outputs. Heavy duty copper free aluminum housing. IP66 and IP68. NEMA 250 6P. ATEX, IECEx, FM, CSA and SIL3 Approved. Capable for Class I Div 1 & 2.

Configure

$5,003.43 
FS24XP-ANGXX
(7141)

HONEYWELL  FS24XP-ANGXX

Honeywell FS24X Plus Triple Infrared (IR3) Flame Detector for detection of hydrocarbon and hydrogen fires. Includes high visibility status LED, SM4 mount and multiple outputs: 4-20 mA, relays, HART and Modbus. 24 VDC. ATEX, IECEx, cFMus (Class I, Div 1, Groups A,B,C,D), INMETRO, SIL2, FM3260 and EN54-10 Approvals. IP66 / IP67 (NEMA 4X).

Configure

$5,062.18 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.