Medc Bg2edc1nr | Call Points | Atex | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MEDC   BG2EDC1NR

SKU# (4150)



MEDC BG2EDC1_NR

ALARM SIGNAL DEVICES / ATEX
CALL POINTS

$353.50  [9 Weeks]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. DC or AC Version. EExed IIC T6 (T4 if resistors or diode fitted) ATEX Approved Ex II 2G. IP66 and IP67.

ATEX

BG2EDC1NR   
353.50

Model
Options
Flap

   9 Weeks  ]
28 Variants of base SKU

This manual fire alarm call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where lightweight combined with a high level of corrosion resistance is required.

FEATURES

  • Zone 0, Zone 1 and Zone 2 use.
  • Exed, Exia or weatherproof.
  • ATEX approved
    • Ex II 1G (Exia)
    • Ex II 2G (Exed)
  • BASEEFA certified.
  • IP66 and IP67.
  • Certified temperature: –40°C to +50°C*.
  • Corrosion resistant red painted GRP
  • Retained stainless steel cover screws.
  • Optional lift flap.
  • Key operated test facility.
  • Lightweight and robust.
  • Breakglass hammer available. (Contact sales office for details)

Specification
Model: BG2W BG2E BG2I
Protection: Dust-tight and Weatherproof Explosion Protected Exed (Increased Safety) Explosion Protected Exia (Intrinsically Safe)
Certification: Not Applicable CENELEC EN50014, 018, 019, 028
Cert. No. BAS02ATEX2105X
ExedIICT6 (switch only)
ExedmIICT4 (other versions)
Suitable for use in Zones 1 & 2
American Bureau of Shipping Type Approval
CENELEC EN50014, 020
Cert. No. Baseefa03ATEX0084X
Exia IIC T4
Suitable for use in Zones 0, 1 & 2
Voltage: Up to 254V Up to 250V (Switch only)
Up to 24V (Resistors & Switch)
Up to 28V (IS)
Certified Temperature: –40°C to +55°C –20°C to +50°C –40°C to +50°C
Ingress Protection: IP66 & 67. IP66 & 67. IP66 & 67.
British Standard for Call Points: BS 5839 : Part 2 : 1983 (BG). BS 5839 : Part 2 : 1983 (BG). BS 5839 : Part 2 : 1983 (BG).
Switch Ratings: d.c.: 0-30V 5A (resistive) or 3A (inductive)
30V-50V 1A resistive or inductive
a.c.: 0-254V 5A resistive or inductive
NOT APPLICABLE
Resistor Values: 100R Minimum* 100R Minimum, 39k Maximum* 470R Minimum*
Cable Entries: 2 x M20 bottom.
Terminals: 6 x 2.5mm2 6 x 2.5mm2 6 x 2.5mm2
Weight: 1.2 Kg.
Material: U.V. resistant glass reinforced polyester.
Finish: Painted Red
Export Info
Made inUnited Kingdom

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    50 Items found.
BExCP3A-PT-ST-NL-RD
(4085)

E2S  BExCP3A-PT-ST-NL-RD

E2S BExCP3A-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3B-PT-ST-NL-RD-06
(5138)

E2S  BExCP3B-PT-ST-NL-RD-06

E2S BExCP3B-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. B type (choose of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3B-PB-ST-NL-06
(5137)

E2S  BExCP3B-PB-ST-NL-06

E2S BExCP3B-PB Push Button Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BGWNNNNN100DSNNN7R
(4159)

MEDC  BGWNNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Weatherproof and dust proof only (Uncertified). IP66 & IP67. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$468.20 
BGIBNNNN100DSNNN7R
(4157)

MEDC  BGIBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exia (Intrinsically Safe). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD. GOST R, CQST and Inmetro approvals also available.

Configure

$485.06 
GNEXCP6A-PB-SNNRD
(4087)

E2S  GNEXCP6A-PB-SNNRD

E2S GNExCP6A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6A-PT-SNNRD
(4088)

E2S  GNEXCP6A-PT-SNNRD

E2S GNExCP6A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-PT-SNSNRD06
(6445)

E2S  GNEXCP6B-PT-SNSNRD06

E2S GNExCP6B-PT Tool Reset Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6B-PB-SNSNRD06
(6444)

E2S  GNEXCP6B-PB-SNSNRD06

E2S GNExCP6B-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

PBUWNNNN0DSNNN7R
(4212)

MEDC  PBUWNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof only version. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$531.43 
PBIBNNNN0DSNNN7R
(4209)

MEDC  PBIBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD, Ex ia IIC T4 Ga, Ex ia IIIC T135C Da. CUTR, Inmetro and CQST certifications also available.

Configure

$548.32 
BGEBNNNN100DSNNN7R
(1573)

MEDC  BGEBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exed (Increased Safety). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2G. GOST R, CQST and Inmetro approvals also available.

Configure

$603.15 
BGULNNNN100DSNNN6R
(4158)

MEDC  BGULNNNN100DSNNN6R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected. Designed for use in hazardous locations and harsh environmental conditions. NEMA 4X and 6. UL approved for Class I, Div 2 and Class II, Div 2 Groups A, B, C and D. Weatherproof only version (for Ordinary Locations) also available.

Configure

$657.93 
PBULNNNN0DSNNN7R
(4211)

MEDC  PBULNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. UL Listed for Class 1, Div 2, Groups A,B,C,D, Class II, Div 2, Groups F & G.

Configure

$666.36 
PBICNNNN0DSNNF7R
(4210)

MEDC  PBICNNNN0DSNNF7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. CSA Certified, Class 1, Groups A,B,C,D

Configure

$670.59 
PBEBNNNN0DSNNN7R
(1574)

MEDC  PBEBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2GD. EExed IIC T6 (T4 if resistors fitted). CUTR, Inmetro and CQST certifications also available.

Configure

$679.14 
D1XCP1PSDXSNNRD
(6407)

E2S  D1XCP1PSDXSNNRD

E2S D1xCP1-PS Explosion Proof Manual Alarm Pull Station for use in harsh operating environments and hazardous locations. NEMA 4X cast aluminium housing. DPDT switch. UL and FM listed.



 
RMS-6T-EXP-WP
(7225)

TOMAR  RMS-6T-EXP-WP

Tomar Electronics RMS-EX-WP Explosion and weather proof fire alarm manual pull station for hazardous locations. NEMA 4X cast aluminum housing. Single or Dual Action. Break Glass. Class I, Division I, Groups B, C, and D; Class II, Division I, Groups E, F, and G; and Class III. UL/ULC listed and FM Approved.

Configure

$745.79 
XAL-53
(6225)

NOTIFIER  XAL-53

Notifier XAL-53 Explosion Proof / Weather Proof Pull Station with Ring. Copper Free Aluminum Enclosure and 3/4" NPT conduits. Suitable for Class I Div 1, Class II Div 1 & 2 and Class III on Hazardous Locations. NEMA 7. UL and CSA Approvals.



 
SM87PBLAI_NNNNNNNNNR
(4219)

MEDC  SM87PBLAINNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,206.27 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.