Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (368)

GDS  C2-20-014-19/00-000-00/0-0-0-0-0/0-0

DETECTORS / GAS DETECTORS
HYDROGEN

$2,290.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS C2-20-014-19/00-000-00/0-0-0-0-0/0-0
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Literature

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Hydrogen (H2) sensor with range 0-1% or 0-4% vol. with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

Part# with Options:        C2-20-014-19/00-000-00/0-0-0-0-0/0-0
Price with Options:        2,290.00

Options:    

Sensor Head (Channel 1)
(1) Sensor Head for GDS C2 for non reactive gases 2
Gas Range
(2) Gas Range for GDS (0-2000 ppm, 0-1% to 0-4% vol) Hydrogen sensors
Relay Output
(3) Relay Output for GDS C2
Analog Output
(4) Analog Output for GDS C2
Digital Output
(5) Digital Output for GDS C2
Audible Alarm
(6) Audible Alarm for GDS C2
Visual Alarm
(7) Visual Alarm for GDS C2
Enclosure Options
(8) Enclosure Options GDS C2
ACK Button
(9) C1D2 Local ACK Button
ACK Button
(10) General Purpose ACK Button (C2)
2nd Input channel
(11) Second 4-20 mA or bridge input channel for GDS C2 controller
Power Supply
(12) Power Supply for GDS C2 controller
Requires extended enclosure

Availability 2 Weeks  ]

The C2 Protector Display & Alarm Controller provides signal conditioning, display and alarm functions for one or two critical input variables.

Versatile

Designed to provide low-cost direct monitoring for one or two gas sensors or flame detectors, the C2 Protector controller offers a highly-integrated, complete solution for detection of hazardous conditions. Versatile input signal conditioning options allow direct connection of any GDS Corp electrochemical sensor, and local or remote support for any GDS Corp combustible, PID or infrared sensor. Both channels can be configured to accept analog inputs from sources such as the GDS-49 Sensor Transmitter, GDS-IR Point Infrared Gas Detector or any standard 4-20mA source.

Additional C2 options include 5A SPDT discrete relays, 4-20mA outputs, light stacks and audible annunciators.

One popular application for the C2 is as a dual gas detector equipped with one local combustible sensor and one local toxic sensor. Alternatively, two combustible locations may be monitored with one sensor local and another remote.

Real-Time Display

A large graphic LCD screen displays input data as calibrated engineering units, bargraphs or 30-minute trends. Three adjustable alarm levels per channel, combined with programmable relays with voting logic allows flexible control of beacons, horns and other warning devices. Highly visible red and yellow LEDs visually indicate alarm status at all times.

Digitally Connected

An optional RS-485 MODBUS® slave port allows multiple C2 controllers to be multi-dropped on a single data highway. The C2 Protector controller is also 100% compatible with the ProtectorHMI Visualization and Historian software that can monitor, display and record data from up to ten C1 Protector or C2 Protector controllers.

Reliability

The C2 Protector controller is CSA certified to CSA C22.2 No. 152 for combustibles and Class I, Division 2, Groups A, B, C, D for use in hazardous areas. An optional NEMA 7 enclosure allows use in Class I Div 1 areas. Up to twelve watts of 24 VDC power is available for auxiliary devices or transmitters.

FEATURES

  • Accepts one or two direct-connect local or remote sensors or 4-20mA
  • Large LCD display shows values, bar-graph and trend data
  • Two programmable 5A SPDT common relays for Alarm 1, Alarm 2, Horn or FAULT
  • Optional 6x relay board for perchannel SPDT contacts
  • Optional dual channel 4-20mA board for current loop output
  • Operates on either +24VDC or 117/240VAC 50/60Hz
  • ACK button silences HORN without affecting alarm relays
  • Relay voting logic reduces need for external hardware
  • Touch and magnetic keys for non-intrusive operation in XP areas
  • Pushbutton zero and span calibra tion for directly connected sensors
  • NEMA 4x approved for Class 1 Div 2 area without purge
  • MODBUS® slave port for easy interface from master devices
  • CSA certified to C22.2 No 152 for combustible gas detection and approved for Class 1, Div 2 Groups A, B, C, D
  • Manufactured in USA

C2 Protector SPECIFICATIONS
Power Input: 24VDC (12 Watt MAX) 85-240 VAC power supply included
Display Backlit 128x64 pixel LCD shows trend, bargraph and engineering units; flashing alarm LEDs indicate alarm status
Input Inputs available for dual catalytic bead LEL, dual toxic / O2, one each catalytic bead & toxic / O2, and dual 4-20mA
MODBUS I/O Optional slave mode RS-232 or RS-485 MODBUS interface
Relay Output Two common output relays configurable for A1, A2, FAIL & HORN ; 5A @ 30VDC / 240VAC resistive load
Analog Output Optional dual channel 4-20mA current loop. Max loop R is 800 ohms with nominal 24VDC
Audible Output Optional 100db alarm (NEMA 4X only)
Temp -25°C to +50°C operating
Housing NEMA 4X approved for Class 1 Div 2 Groups A, B, C, D
NEMA 7 wall-mount approved for Cls 1 Div 1 Groups B, C, D
Dimensions NEMA 4X Non-metallic: 11.25” x 13.31” x 7.25” (w-h-d)
NEMA 4X Painted or stainless: 9.84” x 13.65” x 6.2”
NEMA 7: 13” x 14.25” x 6.25”
Approvals CSA C22.2 No. 1010.1 & 152 for combustibles & ISA S82.02;
UL 1604 / C22.2 No 213 (NEMA 4X = Div 2 Groups A, B, C, D;
NEMA 7 = Div 1 Groups B, C, D) EN55011 & EN61000 (CE Mark)
Warranty 2 years from date of purchase on electronics
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > GDS ELECTROCHEMICAL SMART
    10-8114-R19 Electrochemical DELRIN Sensor configured for Hydrogen (H2) with range 0-1% or 0-4% vol. For direct mount on TRANSMAX and C2 Controller. ..

  • BOARDS > GDS C2 CONTROLLER
    10-0221 GDS 4-20 mA dual channel analog output board for C2 Controllers ..

  • CALIBRATION GAS > HYDROGEN
    CYL-10314080 Calibration Gas Hydrogen (H2), 100 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • CALIBRATION GAS GDS > HYDROGEN
    1200-0545 GDS Gas Detector Calibration Gas Cylinder Hydrogen (H2) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder. ..

  • CALIBRATION KITS GDS > HYDROGEN
    1200-0511 GDS Gas Detector Calibration Gas Kit Hydrogen (H2) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • HYDROGEN IN NATURAL GAS > HYDROGEN
    GDS-68XP1/1-14-19/1-0-0 GDS GDS-68XP Process Gas Monitor with Stainless Steel sensor head configured for Hydrogen (H2) in natural gas with range 0-2000 ppm, 0-1% or 0-4% vol. Uses periodic sampling (from 3x per day to 12x per day) to extend sensor life and minimize discharge of ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > HYDROGEN :    30 Items found.
HD-11
(653)

MACURCO  HD-11

Macurco HD-11 Gas Detector for Hydrogen (H2) 10% LEL. Low voltage and designed for connection to Fire Alarm/Burglary Control Panels, SPDT Alarm and N.C. Trouble Relays. 12-24 VAC or VDC input. Intended for installation buildings in non-hazardous locations such as residences, retail stores, office buildings, and similar facilities.



$237.54 
M001-0018-000
(6329)

MPOWER  M001-0018-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen (H2) 0-1000ppm or 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.

Configure

$298.00 
G02-BM10-100
(3028)

RAE  G02-BM10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Hydrogen (H2) 0-1000 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$555.75 
BWS_-R-Y
(6387)

BW  BWS-R-Y

Honeywell BW Solo Serviceable Single-gas Detector for Hydrogen (H2) 0-1000 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$572.00 
SPSTAXG1
(1487)

HONEYWELL  SPSTAXG1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen (H2) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-1000 ppm, 0-10000 ppm)

Configure

$594.91 
GG-H2-EC-2000
(2965)

CALIBRATION TECHNOLOGIES  GG-H2-EC-2000

CTI GasGuard H2 Hydrogen Catalytic Bead Sensor 0-1% (10000 ppm or 25%LEL) for gas leak detection in battery charging rooms, steel industry, refineries and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$661.20 
2106B1416
(1462)

HONEYWELL  2106B1416

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen (H2) (0-1000 ppm to 0-10000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx Certified.

Configure

$728.91 
GDS-49-1-14-08
(163)

GDS  GDS-49-1-14-08

GDS GDS-49 Remote Gas Detector Transmitter with Stainless steel sensor head configured for Hydrogen (H2) with range 0-1000 to 0-5000 ppm. 2-Wire 4-20 mA transmitter.

Configure

$825.00 
GG-H2-EC-10000-EXP
(5978)

CALIBRATION TECHNOLOGIES  GG-H2-EC-10000-EXP

CTI GG-H2-EC-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen (H2) 0-2000 ppm and 0-10000 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$843.90 
EX-H2-100L-O
(6023)

MACURCO  EX-H2-100L-O

Macurco Ex Series Explosion Proof Catalytic Bead Gas Detector for detection of Hydrogen (H2) 0-100%LEL. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$935.00 
SPXCDULNG1
(665)

HONEYWELL  SPXCDULNG1

Honeywell XCD Sensepoint Gas Detector, Hydrogen (H2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66 for hydrogen (H2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 1,000ppm only UL/CSA Class I Division 1 or ATEX IECEx available.

Configure

$1,045.49 
SPXCDULNG2
(5102)

HONEYWELL  SPXCDULNG2

Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen (H2) with Remote Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 1000 ppm. UL/cCSAus Approved for Class I Div 2.

Configure

$1,192.21 
961-070026-01PG
(6053)

DETCON  961-070026-01PG

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-1%vol Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

961-840026-100G
(6363)

DETCON  961-840026-100G

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-100ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

S3KUL2-XNXXSG1SS
(689)

HONEYWELL  S3KUL2-XNXXSG1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN (H2) with electrochemical sensor, 2-wire 4-20mA loop. Optional ranges: 0-1,000ppm ,0-10,000ppm

Configure

$1,313.67 
ITRANS2-1L00000
(6295)

OLDHAM  ITRANS2-1L00000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Hydrogen (H2) 0-999 ppm. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

GM/EC-01-14-19
(120)

GDS  GM/EC-01-14-19

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (explosion proof ) configured for Hydrogen (H2) with range 0-1% or 0-4% vol. 4-20 mA output transmitter.

Configure

$1,375.00 
EX-H2-1000P-O
(6024)

MACURCO  EX-H2-1000P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Hydrogen (H2) 0-1000ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,432.09 
GMII-01-014-19/00-000-00/0-0
(138)

GDS  GMII-01-014-19/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head configured for Hydrogen (H2) with range 0-1% or 0-4% vol. 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,545.00 
XNXUTAENNNNN-XNXXSG1SS
(839)

HONEYWELL  XNXUTAENNNNN-XNXXSG1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen (H2) compatible with all Honeywell gas sensing technologieswith aluminum housing. 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1. Optional ranges: 0-1000ppm, 0-10000ppm

Configure

$1,655.79 
Page: 1 | 2 | All