Gds Rmii-02-15-04/00-00-00/1-0-1-0 | Hydrogen Sulfide | Gas Detectors (rapid Deployment) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   RMII-02-15-04/00-00-00/1-0-1-0

GDS RMII-02-15-04/00-00-00/1-0-1-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS RigMAX Single Channel Gas Monitor with Integrated strobe and 99dB horn for Hydrogen Sulfide (H2S) with range 0-25 to 0-5000 ppm. Includes backlit display and 100 ft #18GA neoprene power cable. 24 VDC. Aluminium Housing and 4 point magnetic mount. CSA Certified for Class 1, Div 1, Groups B, C & D. *** phased out ***

Inquiry

The RigMAX II is a single point, highly reliable and easily-deployed toxic or combustible gas monitor designed especially for onshore petrochemical monitoring applications.

Based on the GASMAX family of gas monitors widely used in onshore and offshore applications worldwide, the RigMAX II combines a gas monitor, local or remote sensor, warning strobe, horn sounder and 75 ft power cable into one convenient package.

Powered by 24VDC, the RigMAX II includes a magnetic mounting plate that makes installation a snap on any metal vertical surface. In addition, the plate is pre-drilled to support 1 1/2” pole mount U-bolt hardware or standard through-bolts.

Intuitive User Interface

The backlit LCD and highly visible LEDs display alarm status and real-time gas values or 30-minute trend data while an event log stores time-stamped calibration and alarm events for later review. An intuitive menu-driven operator interface (no blinking LEDs!) and built-in, text- prompted calibration procedure makes it easy to keep the RigMAX II operating at peak efficiency.

Flexibilty

The RigMAX II supports a wide range of toxic sensors, including Hydrogen Sulfide, Sulfur Dioxide, Hydrogen, Hydrogen Cyanide and many more, including an Hydrogen Sulfide sensor designed specifically for low humidity applications. The RigMAX II can also be configured for infrared or catalytic bead sensors to detect a wide range of combustibles. A selection of red, amber, blue or purple strobes are available for rapid recognition of any gas emergency, and the horn can be programmed to provide a range of unique warning tones.

The RigMAX II is a convenient and easy solution for toxic gas monitoring in rough field conditions where reliability and rapid installation are critically important.

FEATURES

  • Robust, highly reliable single-point monitor for Hydrogen Sulfide gas
  • Integrated warning strobe and 99 dB horn provide quick response
  • Local or remote sensor with optional high visibility stand
  • Four-point magnetic mount makes installation quick and easy
  • Easy-to-use prompted calibration for rapid setup and commissioning
  • Fault supervision circuitry detects failed or missing sensor element
  • Backlit display for better visibility at night or in low light conditions
  • Security software lock prevents tampering or resetting alarms
  • Automatic recognition of GDS Corp Smart Sensors
  • Built-in Event Log records alarms, power cycles and calibrations
  • Includes 100 ft #18GA neoprene power cable wth flying leads
  • Remote sensor includes jbox, cable glands and 10’ neoprene cable
  • Manufactured in USA

RIGMAX II SPECIFICATIONS
Power Input: +24VDC ± 10% at less than 10 watts
Display GASMAX II gas monitor with backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units. Alarm LEDs show Alarm 1, Alarm 2 and Fault.
Sensor Input Local or remote toxic sensor for oxygen, carbon monoxide, chlorine, hydrogen, hydrogen sulfide (normal and low humidity), sulfur dioxide, ammonia and mercaptan.
Catalytic bead sensor for detection of combusible levels of hydrocarbons or hydrogen Photoionization detector (PID) for detection of benzene, toulene and other volatile organic compounds in low ppm levels.
Output Alarm 1 Ouput: High visibility 24V strobe in red, amber, blue or purple. Sixty to 80 flashes per minute; 10,000 hour strobe lamp; 1.9 joules / flash; 190,000 candlepower.
Alarm 2 Output: Horn sounder, 91-97 dB at 10 feet. Eight user selectable tones: horn, chime, siren, slow whoop, temporal, hi-lo and single stroke bell.
Temp -10°C to +50°C operating range
Housing Aluminum housing with epoxy paint standard; Optional #316 stainless steel housing (specify [SS] in part number)
Mounting Four-point magnetic mount designed for flat surface. Mounting plate drilled for 2” pole mount and standard through-bolts
Dimensions Local Sensor: Width 11” (280 mm), Height 18” (457 mm), Depth 5” (127 mm)
Shipping weight 9 pounds (3 kg)
Approvals GASMAX CSA Certified for Class I, Div 1, Grps B, C, D.
Optional Class 1 Div 2 rated strobes
Horn sounder not for use in hazardous areas
Warranty 2 years on electronics and one year on sensors
> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
1200-0268
(3182)

GDS  1200-0268

GDS Gas Detector Calibration Gas Cylinder Hydrogen Sulfide (H2S) 25ppm. Balance Air. 58L Aluminium Cylinder.

1200-0269
(3179)

GDS  1200-0269

GDS Gas Detector Calibration Gas Cylinder Hydrogen Sulfide (H2S) 100ppm. Balance Methane. 58L Aluminium Cylinder.

10-9515-R04
(328)

GDS  10-9515-R04

Electrochemical Smart Sensor configured for Hydrogen Sulfide (H2S) with range 0-25/0-5000 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-49, GDS-58XP.

1200-0517
(3113)

GDS  1200-0517

GDS Gas Detector Calibration Gas Kit Hydrogen Sulfide (H2S) 50ppm. Balance Air. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0538
(3112)

GDS  1200-0538

GDS Gas Detector Calibration Gas Kit Hydrogen Sulfide (H2S) 25ppm. Balance Air. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0515
(3109)

GDS  1200-0515

GDS Gas Detector Calibration Gas Kit Hydrogen Sulfide (H2S) 100ppm. Balance Methane. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

> HYDROGEN SULFIDE :    39 Items found.
M015-0002-000
(6332)

MPOWER  M015-0002-000

mPower UNI 321 Disposable Single Gas Detector for detection of Hydrogen Sulfide (H2S) 0.1-100ppm. Up to 36 months of live. Large LCD display will show time remaining or low/high alarm levels when hit, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$108.80 
BWC2-H
(4263)

BW  BWC2-H

BW Clip portable gas detector 2 year maintenance free for Hydrogen Sulfide (H2S). Low alarm set at 5 ppm or 10ppm, High alarm set to 10 ppm or 15 ppm. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

M001-0054-000
(6001)

MPOWER  M001-0054-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Sulfide (H2S) 0-100ppm to 0-1000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$134.40 
BWC2R-H
(5148)

BW  BWC2R-H

BW Clip Real Time portable gas detector with 2 year maintenance free for Hydrogen Sulfide (H2S). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWC3-H510
(4268)

BW  BWC3-H510

BW Clip portable gas detector 3 year maintenance free for Hydrogen Sulfide (H2S). Configurables Low and high alarm (ppm). UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

TX1-2
(5966)

INDUSTRIAL SCIENTIFIC  TX1-2

Industrial Scientific Tango TX1 Gas Detector for Hydrogen Sulfide (H2S) 1-500 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

BWC3R-H
(5152)

BW  BWC3R-H

BW Clip Real Time portable gas detector with 3 year maintenance free for Hydrogen Sulfide (H2S). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWS1-HL-Y
(6389)

BW  BWS1-HL-Y

BW Solo Serviceable Single-gas Detector for Hydrogen Sulfide (H2S) 0-200 ppm or 0-500 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-6424
(6805)

PROSENSE  PC3-6424

Prosense PC3-6424 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with range 0-100 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$514.80 
P-6434
(6775)

PROSENSE  P-6434

Prosense P-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$592.02 
TX-6-HS
(2045)

MACURCO  TX-6-HS

Macurco TX-6-HS low voltage Gas Detector, Controller and Transducer for Hydrogen Sulfide (H2S) 0-50 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$648.99 
TX-12-HS
(3419)

MACURCO  TX-12-HS

MACURCO TX-12-HS line voltage Gas Detector, controller and transducer for Hydrogen Sulfide (H2S) 0-50 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$656.26 
SPSTAXH1
(1474)

HONEYWELL  SPSTAXH1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen Sulfide (H2S) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-20 ppm, 0-50 ppm, 0-100 ppm)

Configure

$668.93 
364-455-01-365-756-11100
(6154)

DELPHIAN  364-455-01-365-756-11100

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Sulfide (H2S) 0-25, 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PQN-6434-1/2
(6953)

PROSENSE  PQN-6434-1/2

Prosense PQN-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$772.20 
XT-00H0-Y-NA
(580)

BW  XT-00H0-Y-NA

GasAlertMax XT 4-Gas Detector for H2S ( Hydrogen Sulfide). Monitors up to 4 gas hazards for confined space entry and remote sampling.

OI-6000-EC-H2S-X-R_-DC-C
(6830)

OTIS  OI-6000-EC-H2S-X-R-DC-C

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Hydrogen Sulfide (H2S) 0-100ppm. Non explosion proof. Wired power (3-Wire) (12 to 35 VDC) with 4-20 mA analog, RS-485 Modbus and 2 relay outputs. 3 Push-Button Interface. IP 66/67. Optional radio. UL Approved.

PQD-6434-1/2
(6725)

PROSENSE  PQD-6434-1/2

Prosense PQD-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$926.64 
OI-6000-EC-H2S-X-X-O
(6834)

OTIS  OI-6000-EC-H2S-X-X-O

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Hydrogen Sulfide (H2S) 0-100ppm. Explosion Proof Wired power (3-Wire). (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs. 3 Push-Button Interface. IP 66/67. Optional alarm relays and Radio. CSA Approved for Class I Div 1. ATEX Zone 1 and IECEx Certified.

GG-H2S-50
(4136)

CALIBRATION TECHNOLOGIES  GG-H2S-50

CTI GasGuard H2S Hydrogen Sulfide Electrochemical Sensor (0-50 ppm) for gas leak detection in process areas, tank storage, sanitizing systems and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,088.34 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.