GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head (non-XP) and integrated sensor configured for Hydrigen Chloride (HCL) with range 0-30 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Part# with Options:        GM/TX/03-17-12/00-00-00/1-0900
Price with Options:        2,315.00

Options:    

Configuration
(1) Configuration for GDS GASMAX TX
Sensor Head (Channel 1)
(2) Sensor Head for GDS GMTX CH1 (reactive gases)
Enclosure
(3) Stainless Steel Enclosure for GDS
Tag
(4) Tag for GDS
Antenna
(5) Antenna Style for Gasmax wireless
Rated Antenna
(6) Rated Antenna Coupler for C1D2 (GDS)
DC Version
(7) DC Version for GASMAX TX

  Availability 2 Weeks  ]

Features

  • Third-generation ultra-low power design for toxics and combustibles
  • Single or dual channel, local or remote Smart Sensors
  • Graphic display shows values, units, trend graph, alarm levels
  • Power ON / Power OFF using magnetic wand only
  • Non-intrusive, user-prompted calibration procedure
  • Transmits all setup information to new C2/TX Wireless Site Manager
  • Reliable Frequency-Hopping Spread Spectrum technology
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • Typical > 1 mile range with local ‘whip’ antenna (900Mhz)
  • For VOC applications, see the GASMAX IIx gas monitor
  • Manufactured in USA

The GASMAX TX wireless gas monitor combines the latest in ultra-low power microprocessor design, infrared sensor technology and ease-of-use features to deliver the most advanced wireless toxic and combustible gas monitor available.

The GASMAX TX is compatible with all GDS Corp toxic sensors, including hydrogen sulfide, carbon dioxide, oxygen, hydrogen cyanide and many others. In addition, the GASMAX TX also supports the new SmartIR/LP low-power infrared sensor for hydrocarbon combustibles or carbon dioxide.

Advanced User Interface

The highly visible LCD display shows sensor status, calibrated engineering values and programmable tag name, along with a trend screen that displays the most recent 30 minute trend. A real-time clock and event log records calibration and alarm events for later review, and a menu- driven operator interface using magnetic keys eliminates all analog potentiometers and enables power on/off switching and setup without opening the enclosure.

Fully Integrated Wireless Solution

An internal easily-replaceable D-cell lithium battery and 900Mhz or 2.4Ghz license-free Frequency-Hopping Spread Spectrum (FHSS) wireless modem provide up to six months of continuous operation in typical applications. FHSS technology provides the best choice for long-range, reliable communications with high levels of noise immunity. When gas is present, the GASMAX TX transmits gas level data on six second intervals.

Complete Wireless System

The GASMAX TX is designed to operate most efficiently with the new mult-channel C2/TX Wireless System Manager. The C2/TX WSM supports up to 32 GASMAX/TX monitors and offers 8x relay outputs as well as optional serial MODBUS, data logging and WiFi access. In addition to the new C2/TX WSM, the GASMAX TX also works with GDS Corp C1 Protector 8/16 channel controller / receivers, C2 Quad Protector 4 channel controller / receivers and the new C64 Protector multi-channel controller.

Power Input Replaceable internal D-cell lithium battery; six-month operation (typical)
Display64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units display.
InputSingle or dual channel input from 10-98xx toxic or 10-97xx infrared hydorcarbon combustible sensors
Standard OutputLicense-free 900Mhz or 2.4Ghz frequency-hopping spread spectrum (FHSS) wireless modem with data encryption
900MHz power adjustable from 10mW to 1.0 watt
2.4GHz output set at 50mW or 125mW (US only)
Receiver sensitivity typically -100dBm
Temp-25°C to +55°C (see sensor limitations)
HousingAluminum housing with epoxy paint standard; #316 stainless steel optional
DimensionsWidth 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm)
Shipping weight 6.5 pounds (3 kg)
ApprovalsFCC 15.247 & Industry Canada (IC)
WarrantyTwo years on electronics and one year on sensors from date of purchase

  • SENSORS (REPLACEMENT) > GDS DIGITAL
    10-9817-R12 Electrochemical Smart Sensor configured for Hydrogen Chloride (HCL) with range 0-30 ppm. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP...

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional..


  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


  • MULTI-POINT CONTROLLERS > 64-CHANNEL C64
    C64/PM-00-00-00/0-00-0/00/0-0-0-0/0-0-0 GDS C64 Protector Controller in Panel Mount (includes hardware) with up to 64 channels of analog, bridge, digital, wireless or MODBUS TCP. Large color LCD Display shows values, trends, bargraph and more. Pushbutton ZERO and SPAN calibration for direct sen..


  • MULTI-POINT CONTROLLERS > 32-CHANNEL WIRELESS
    C2/TX/1-1/0-0/1-1-0900 GDS C2/TX Multi-Channel Wireless Display & Alarm Controller for Critical Gas Monitoring Applications. Monitors up to 32 GASMAX TX detectors. Large LCD Display. 900 MHz or 2.4 GHz FHSS radios. 8 Standard programmable relays. 24VDC or 117/240VAC. Optional M..


  • CALIBRATION GAS GDS > HYDROGEN CHLORIDE
    1200-0291 GDS Gas Detector Calibration Gas Cylinder Hydrogen Chloride (HCl) 10ppm. Balance Nitrogen. 58L Aluminium Cylinder. ..


  • CALIBRATION KITS GDS > HYDROGEN CHLORIDE
    1200-0512 GDS Gas Detector Calibration Gas Kit Hydrogen Chloride (HCl) 10ppm. Balance Nitrogen. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS (WIRELESS) > HYDROGEN CHLORIDE :    14 Items found.
MP100-HCI-15
(5998)

MACURCO  MP100-HCI-15

Macurco UNI Portable Single Gas Detector for detection of Hydrogen Chloride (HCI) 0-15ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$276.25 
6300-1016
(4499)

BACHARACH  6300-1016

Bacharach MGS-150 Gas Detector Transmitter with electrochemical sensor for Hydrogen Chloride (HCl) 0-50 ppm. 4-20mA, 0-5V, 0-10V, 1-5V or 2-10V user selectable analog outputs. Onboard Alarm LED, audible buzzer and alarm relay. IP41 Housing. CE, IEC61010, Exd and UL CSA Approvals.



$522.00 
TM-EC-48-17-12-0
(3392)

GDS  TM-EC-48-17-12-0

GDS TRANSMAX EC Loop-Powered Gas Monitor with stainless steel sensor head and integrated sensor configured for Hydrogen Chloride (HCl) for range 0-30 ppm. 2-wire 4-20mA current sink output and large LCD Display. Polycarbonate housing (IP66/IP67).

Configure

$1,240.00 
TMII-48-17-12/00-00-00/0-0
(154)

GDS  TMII-48-17-12/00-00-00/0-0

GDS TRANSMAX II Gas Detector with Local DELDRIN sensor head (non-XP) with integrated sensor configured for Hydrogen Chloride (HCl) for range 0-30 ppm with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU, 4-20mA output transmitter.

Configure

$1,365.00 
S3KUL2-XNXXSR1SS
(692)

HONEYWELL  S3KUL2-XNXXSR1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CHLORIDE (HCI) with electrochemical sensor, 2-wire 4-20mA loop, 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

Configure

$1,426.36 
GM/EC-03-17-12
(129)

GDS  GM/EC-03-17-12

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Hydrogen Chloride (HCL) with range 0-30 ppm, 4-20 mA output transmitter.

Configure

$1,525.00 
967-090990-030
(6090)

DETCON  967-090990-030

Detcon DM-700-HCL Electrochemical "Smart" Hydrogen Chloride (HCL) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

EX-HCL-30P-O
(6026)

MACURCO  EX-HCL-30P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Hydrogen Chloride (HCL) 0-30ppm. Includes 4-20 mA Output, Three Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,574.12 
5100-21-IT-A1-01-0-0
(3078)

SIERRA MONITOR  5100-21-IT-A1-01-0-0

Sierra Monitor 5200-21-IT Toxic Gas Leak Detector for Hydrogen Chloride (HCl) 0-20ppm Electrochemical Sensor. ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups B, C, D.

Configure

$1,616.00 
GMII-03-017-12/00-000-00/0-0
(141)

GDS  GMII-03-017-12/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Hydrigen Chloride (HCL) with range 0-30 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,695.00 
XNXUTAENNNNN-XNXXSR1SS
(843)

HONEYWELL  XNXUTAENNNNN-XNXXSR1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Chloride (HCl) 0-10ppm (10.0 to 20.0ppm, 1.0ppm) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,768.48 
GM/ECx-03-17-12-1-0900
(1815)

GDS  GM/ECx-03-17-12-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (IS) configured for Hydrogen Chloride (HCL) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$2,075.00 
GMCX-03-17-12/00-00-00/0
(3291)

GDS  GMCX-03-17-12/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Hydrigen Chloride (HCL) with range 0-30 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. For non-clasified areas only

Configure

$2,190.00 
GMIIx-03-017-12/00-000-00/1-0900
(1838)

GDS  GMIIx-03-017-12/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head (non-XP) configured for Hydrogen Chloride (HCL) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.