Notifier Pf24v | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   PF24V

SKU# (3237)
NOTIFIER PF24V
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier PF24V ExitPoint Directional Sounder with Voice Messaging designed for open areas, corridors or stairs. Reduces evacuation times up to 75%. 24VDC. UL, FM, CSFM and MEA Approved.

Please Email us your request for quote   

   4 Weeks  ]

The ExitPointTM Directional Sounder has an integral audio amplifier that produces a pulsating sound consisting of broad- band low, mid, and high range sounds. The broadband noise makes it possible to determine the location of the sound. There are four pulse patterns that can be used to create an egress pathway out of a building and to mark perimeter exits. In addition to the broadband noise, the sounder is capable of playing an alert message in the form of a recorded voice mes- sage or other audible signals. These messages will instruct the occupants of what action to take as they approach the direc- tional sounder, and will allow them to react quickly and confi- dently when the sounder is activated. Fifteen different language combinations are available to instruct occupants that they are nearing an exit, a stairway up, a stairway down, or an area of refuge. The directional sounder also incorporates an optional disable feature for use in conjunction with a control module or heat sensor.

The directional sounder features a number of field selectable power settings including high, medium-high, medium-low, and low. Installation ease and pleasing aesthetics are achieved by a low profile compact design, and by the ability to flush mount in a 4” x 4” x 21⁄4” back-box.

ExitPoint directional sounders, fitted in addition to normal building evacuation sounders, draw people to evacuation routes in both good and poor visibility. The directional sounder can be used in a wide range of building applications. Trials consistently have shown an improvement of up to 75 percent in evacuation times in smoke and up to 35 percent without smoke. The 2007 Edition of NFPA 72 now provides installation and maintenance guidelines on directional sounders.

FEATURES

  • Listed to UL 464 (indoor applications only)
  • Five field-selectable power settings
  • Four field-selectable routing evacuation patterns
  • Constructed to be effective in unfamiliar surroundings or poor visibility
  • Designed to work in open areas, corridors, or stairs
  • Fifteen different language selections available
  • Reduces evacuation times by as much as 75 percent
  • Optional disable feature for use in conjunction with a control module or heat sensor
  • Low profile, compact design
Agency Listings and Approvals

Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status.

  • UL Listed: S4011
  • ULC Listed: S8971
  • FM Approved
  • CSFM: 7135-1653:175
  • MEA Approved: 492-04-E Vol. 2

PF24V(A) SPECIFICATIONS
Voltage Input: Regulated 24 Volts
Operating Voltage Range: 16 to 33 Volts
Operating Temperature: 32 ° F to 120 ° F (0 ° C to 49 ° C)
Power Setting: High, medium-high, medium, medium-low, low
Input Terminals: NS Input Terminals:
Speaker Size: 4” (101 mm)
Grille Size: 4 7/8” (127 mm)

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NOTIFIER :    42 Items found.
BAT-1270-BP
(6944)

NOTIFIER  BAT-1270-BP

Notifier BAT-1270-BP rechargeable battery. 12VDC. 7 AH. 5-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-12260-BP
(6941)

NOTIFIER  BAT-12260-BP

Notifier BAT-12260-BP rechargeable battery. 12VDC. 26 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-12550
(6943)

NOTIFIER  BAT-12550

Notifier BAT-12550 rechargeable battery. 12VDC. 55 AH. Overcharge protected. ABS high-impact case.



 
ISO-6
(6934)

NOTIFIER  ISO-6

Notifier ISO-6 Six Fault Isolator Module for Notifier Fire Alarm Control Panels (FACPs). Powered by SLC loop. Class B isolator circuits. UL, FM, CSFM Approved.



 
LDM-32
(6870)

NOTIFIER  LDM-32

Notifier LDM-32 Lamp Driver Module for annunciation and control of NOTIFIER Intelligent Fire Alarm Control Panels. Up to 32 alarm indications. 24 VDC. EIA-485 interface. UL, ULC, MEA, CSFM and FM Listed.



 
BAT-12120-BP
(6940)

NOTIFIER  BAT-12120-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 12 AH. 4-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-1250-BP
(6942)

NOTIFIER  BAT-1250-BP

Notifier BAT-1250-BP rechargeable battery. 12VDC. 5 AH. 10-unit bulk pack, Overcharge protected. ABS high-impact case.



 
XP6-R
(6930)

NOTIFIER  XP6-R

Notifier by Honeywell XP6-R(A) Six Relay Control Module with Form-C Relays. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP6-C
(5122)

NOTIFIER  XP6-C

Notifier XP6-C Six Circuit Supervised Control Module for horns, strobes or bells that require an external power supply. Short-circuit-protection. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP10-M
(3724)

NOTIFIER  XP10-M

Notifier XP10-M Ten Input Monitor Module for intelligent alarm systems. Up to 10 addresable Class B or 5 addressable Class A devices. SLC inputs. Green LED indicators. Flexible mounting options. FlashScan or CLIP operation. UL Listed. CSFM, FM, MEA and MSTM approved.



 
PSE-6
(6924)

NOTIFIER  PSE-6

Notifier PSE-6 (6 amp) or PSE-10 (10 amp) 24 VDC Remote Power Supply Expander with battery charger for 12 or 24 volt alarm control panels (FACP). Up to 7 outputs. UL, ULC, CSFM and FM listed.

APS2-6R
(6938)

NOTIFIER  APS2-6R

Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

BAT-121000
(6939)

NOTIFIER  BAT-121000

Notifier BAT-121000 rechargeable battery. 12VDC. 100 AH. Overcharge protected. ABS high-impact case.



 
NCM-F
(3507)

NOTIFIER  NCM-F

Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

HPFF12
(6600)

NOTIFIER  HPFF12

Notifier HPFF12(E) 12 Amp and 24 Volt Power Supply to extend the power of existing Notification Appliance Circuits (NACs) or provide power for auxiliary devices. 4 NAC and 1 aux outputs. 8 status LEDs. UL, CSFM and FM listed.

KDM-R2
(6932)

NOTIFIER  KDM-R2

Notifier KDM-R2 Keyboard Display Module for CPU2-640. 80 character display and QWERTY programming keypad included.



 
ACPS-610
(6936)

NOTIFIER  ACPS-610

Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

AMPS-24
(6937)

NOTIFIER  AMPS-24

Notifier AMPS-24 Addressable Power Supply for NFS-3030, NFS2-3030 and NCA-2. Charges 7 AH to 200 AH batteries. SLC circuit. UL, ULC, CSFM and FM listed.

LEM-320
(6872)

NOTIFIER  LEM-320

Notifier LEM-320 Loop Expander Module for NOTIFIER’s ONYX Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
LCM-320
(6871)

NOTIFIER  LCM-320

Notifier LCM-320 Loop Control Module for NOTIFIER’s ONYX Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.