Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (3004)

HONEYWELL  XCDRFDL

$1,330.21     Availability: 4 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount
      



HONEYWELL XCDRFDL
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

Honeywell Sensepoint XCD RFD (Remote Flammable Detector) Kit. Includes transmitter with LM25, 3/4“NPT Entry, 705 sensor, and 3 wire junction box. Tri-colour backit display. Outputs include 2 programmable alarm relays, 1 programmable fault relay, 4-20mAoutput (sink or source selectable). Sensor can be mounted up to 30 metres (100 feet) from transmitter. cCSAus Certified for North America. Class 1, Div 1, Groups B, C, & D.

Part# with Options:        XCDRFDL
Price with Options:        1,330.21

Options:    

Enclosure
(1) Enclosure for Honeywell Sensepoint XCD RFD
Modbus
(2) Modbus for Honeywell Sensepoint XCD RFD
Sensor
(3) Sensor for Honeywell XCD RFD Kit
Calibration 0-100% LEL
(4) Other Combustible gas calibration for Cat Bead Honeywell XCD/XNX
Custom Tag
(5) SSTAG Stainless Steel Custom Tag for Honeywell Gas Detectors

  Availability 4 Weeks  ]

Sensepoint XCD RFD (Remote Flammable Detector) has been specifically designed for use with remotely mounted flammable gas sensors. This configuration is ideal for applications where the sensor is required to be mounted remotely from the transmitter in areas where temperatures are well above ambient (up to 150°C/302°F), or that are difficult to access. The transmitter can be mounted at a suitable location away from this area where it is easy to access, view its display and interact with via the user interface.

Applications

  • Compatible with high temperature sensors for use in and around Gas Turbine Enclosures and solvent based printing and coating drying ovens
  • Compliant with the requirements of HSE guidance note PM84
  • Transmitter can be mounted in easy to access area even if sensor is in a hard to access or restricted access area
  • Sensor can be mounted up to 30 metres (100 feet) from transmitter
  • Standard temperature catalytic and infrared sensor types also available
Reliable detection

  • Compatible with Honeywell Analytics’ proven catalytic bead flammable gas sensors
  • High temperature gas sensors have thermally matched beads for highest accuracy and stability enabling low alarm levels
  • Gas sensors use long life, poison resistant beads as standard, reducing ongoing cost of ownership
Easy to Use

  • Easy to read tri-colour backlit display with digits, bar graph and icons
  • Fully configurable via non-intrusive magnetic switches
  • Selectable sink or source 4-20mA output
  • Auto-inhibit during maintenance prevents false alarms
Cost Effective

  • Sensepoint XCD common transmitter platform
  • Reduces training costs
  • Reduced spares and stock costs
  • Non-intrusive, one-man operation reduces cost of maintenance
  • Optional Sensepoint XCD plug-in sensor reduces maintenance time further

Sensepoint XCD RFD is suitable for use with several Honeywell Analytics’ sensors; the Sensepoint XCD catalytic bead and infrared type plug-in sensors and the Sensepoint standard and high temperature sensors. These sensors can be mounted up to 30 metres (100 feet) away from the transmitter thereby accommodating even the most remote and inaccessible applications.

The gas range is user adjustable at the transmitter from 0-100%LEL down to 0-20%LEL. The 0-20%LEL range is particularly suited for use with the Sensepoint high temperature sensors that have thermally matched beads providing optimum accuracy and stability allowing alarm set points as low as 5%LEL.

The transmitter’s tri-colour backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

Outputs include 2 programmable alarm relays, 1 programmable fault relay as well as 4-20mA output (sink or source selectable). The range, relay operation, alarm set points and electronic tag number of the detector can be adjusted using the transmitter’s LCD and the non-intrusive magnetic switches.

Outputs are automatically inhibited during adjustment thereby reducing the risk of false alarm at the control panel during maintenance.

The Sensepoint XCD Remote Flammable Detector (RFD) can be used with Sensepoint XCD remote flammable sensors (Catalytic and IR), or with the Sensepoint range of flammable gas detectors. The sensors can be directly mounted to the M25 entry at the bottom of the transmitter, or remotely mounted to suitable junction boxes or duct mounting assemblies. Sensepoint flammable detectors are available in both standard and high temperature versions.

Sensepoint XCD RFD uses three instantly recognisable ‘traffic light’ colours to indicate its status. The large tri-colour backlit LCD flashes red to indicate an alarm, flashes yellow to indicate a fault and is steady green to indicate normal operation. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number o

Sensepoint XCD RFD Transmitter
Use 3 wire 4-20mA gas transmitter for use with remotely mounted flammable gas detectors to protect plant and personnel from flammable gas hazards. Transmitter incorporates in-built alarm and fault relays, local tri-colour LCD display and is fully configurable via non-intrusive magnetic switch interface.
Electrical
Input Voltage Range 18 to 32VDC (24VDC nominal)
Max Power Consumption 5 Watts
Current Output Sink or source
≥0.0<1.0mA Fault
2.0mA or 4.0mA Inhibit (during configuration/user settings)
4.0mA to 20.0mA Normal gas measurement
22.0mA Maximum over range
Terminals 18 x screw terminals suitable for wire diameter 0.5mm 2 to 2.5mm 2 (20AWG to 14AWG)
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energised de-energised (programmable)
Alarm relays default normally open/de-energised. Fault relay default normally open/energised
Construction
Material Transmitter Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: Sensepoint XCD plug-in sensor and Sensepoint High Temperature sensor: 316 stainless steel. Sensepoint Standard Sensor: PPS
Weather Protection: Plastic
Weight (approx) Aluminium Alloy LM25: 2.0kg (4.4lbs)
316 Stainless Steel: 5.0kg (11lbs)
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts
Optional pipe mounting kit for horizontal or vertical pipe Ř1.5 to 3" (2" nominal)
Entries European ATEX/IECEx versions: 2 x M20 side entries and 1 x M25 bottom entry. Suitable blanking plug supplied for use if only 1 side entry used. Seal to maintain IP rating
Certification
European ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
International IEC Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
China GB Ex d IIC T4 GB3836.1&2 -2000, PA, CCCF
Korea KTL Ex d IIC T6 (-40°C to +65°C)
EMC CE: EN50270:2006 EN6100-6-4:2007
Environmental
IP Rating IP66 in accordance with EN60529:1992
Transmitter Certified Operating Range -40oC to +65oC (-40oF to +149oF)
Note: The detector display may become illegible at temperatures below -20°C, but the detector continues its gas monitoring function. The display is not damaged and recovers when the temperature rises back above -20°C.
Operating Humidity Continuous 20-90%RH (non-condensing), Intermittent 0-99%RH (non-condensing)
Operating Pressure 90-110kPa
Storage Conditions -25°C to +65°C (-13°F to 131°F)
Transmitter Ordering Information
Standard Supply Sensepoint XCD RFD is supplied complete with integral wall mounting plate, 2 x M20 side entries and 1 x M25 bottom entry. 1 x M20 plug, Allen key for locking screw, operating magnet, quick start guide and instruction manual CD. Default settings, ranges and calibrations are 100% tested at the factory. Each unit is supplied with a test certificate.
Shipping Details Shipping carton dimensions: L312mm (12.3”) x W223mm (8.8”) x D110mm (4.3”) Approximate weight: aluminium 2.5kg (5.5lbs), stainless steel 5.5kg (12.1lbs)
Detectable Gases and Sensepoint XCD RFD Sensor Performance
Gas Selectable Full Scale Range Default Range Steps Selectable Cal Gas Range Default Cal Point Response Time (T90) Secs
Sensepoint Standard Temperature Sensor 25 to 95% of selected full scale range
Flammable 1 to 8* 20 to 100%LEL 100%LEL 10%LEL 50%LEL <25
Sensepoint High Temperature Sensor
Flammable 1 to 8* 20 to 100%LEL 100%LEL 10%LEL 50%LEL <10
Plug-in Sensepoint XCD Catalytic Bead Sensors
Flammable 1 to 8* 20 to 100%LEL 100%LEL 10%LEL 50%LEL <25
Plug-in Sensepoint XCD Infrared Sensors 30 to 70% of selected full scale range
Methane 20 to 100%LEL 100%LEL 10%LEL 50%LEL <30
Propane* 20 to 100%LEL 100%LEL 10%LEL 50%LEL <30
Carbon Dioxide* 2.00%Vol. 2.00%Vol. n/a 50%LEL <30
Detectable Gases and Sensepoint XCD RFD Sensor Performance
Gas Accuracy Min Operating Temperature Max Operating Temperature A1 Default Alarm Point A2 Default Alarm Point
Sensepoint Standard Temperature Sensor
Flammable 1 to 8* <+/- 1.5%LEL -55°C / -67°F 80°C / 176°F 20%LEL ▲ 40%LEL ▲
Sensepoint High Temperature Sensor
Flammable 1 to 8* <+/- 1.5%LEL -55°C / -67°F 150°C / 302°F 20%LEL ▲ 40%LEL ▲
Plug-in Sensepoint XCD Catalytic Bead Sensors
Flammable 1 to 8* <+/- 1.5%LEL -40°C / -40°F 65°C / 149°F 20%LEL ▲ 40%LEL ▲
Plug-in Sensepoint XCD Infrared Sensors
Methane <+/- 1.5%LEL -20°C / -4°F 50°C / 122°F 20%LEL ▲ 40%LEL ▲
Propane* <+/- 1.5%LEL -20°C / -4°F 50°C / 122°F 20%LEL ▲ 40%LEL ▲
Carbon Dioxide* <+/-0.04%Vol. -20°C / -4°F 50°C / 122°F 0.40%V/V. ▲ 0.80%V/V. ▲

*Contact Honeywell Analytics for availability


  • ACCESSORIES > HONEYWELL XCD
    00780-A-0035 Honeywell Calibration Cup Gas Flow Adaptor (for use with 705 sensors) ..

  • ACCESSORIES > HONEYWELL XCD
    00780-A-0076 Honeywell Weather Protection Stainless Steel for 705 HT ..

  • ACCESSORIES > HONEYWELL XCD
    02000-A-1635 Honeywell Weather Protection Housing ..

  • ACCESSORIES > HONEYWELL XCD
    02000-A-1640 Honeywell Nylon Weather Protection for Combustible Sensor ..

  • ACCESSORIES > HONEYWELL XCD
    02000-A-1642 Honeywell Collecting Cone (for use with MPD, Sensepoint and 705 sensors) ..

  • ACCESSORIES > HONEYWELL XCD
    1283-1047 Honeywell Duct Mount Adaptor Assembly for Duct Mounting XCD-RTD, XCD-RFD, Sensepoint Toxic, Sensepoint Combustible, 705 and XNX w/70 ..

  • ACCESSORIES > HONEYWELL XCD
    2441-0022 Honeywell UL/CSA Aluminum 6 wire Junction Box ..

  • ACCESSORIES > HONEYWELL XCD
    SPXCDMTBR Honeywell Pipe Mounting bracket (inc. fixings and hex wrench set) ..

  • ACCESSORIES > HONEYWELL XCD
    SPXCDSDP Honeywell Sunshade / Deluge Protection. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > LEL CATALYTIC BEAD :    21 Items found.
SPSTAXF1
(1475)

HONEYWELL  SPSTAXF1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Methane (CH4) 0-100% LEL (combustibles) complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 3 wire bridge output. ATEX Approved. Poison resistant catalytic bead.

Configure

$329.94 
2106B1200
(1469)

HONEYWELL  2106B1200

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. ATEX/IECEx Certified.

Configure

$396.94 
SPC3-3355-200US
(2911)

INTEC  SPC3-3355-200US

Intec Controls PolyGard SPC3-3300 Sigle-Point Gas Detector for Combustibles 0-100% LEL (Catalytic Bead), 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. Available gases: Methane, Methyl Ethyl Ketone, n-Butane, n-Octane, n-Pentane, Propane, Acetone, Jet A, JP8 and Toluene.

Configure

$529.88 
SPC3-3380-200US
(2910)

INTEC  SPC3-3380-200US

Intec Controls PolyGard SPC3-3300 Sigle-Point Gas Detector for Combustibles 0-100% LEL (Catalytic Bead), 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. Available gases: Ammonia, Ethylene, Ethyl Alcohol, Ethyl Acetate, Benzene, n-Hexane, n-Heptane, Hydrogen, Isopropyl Alcohol and Methanol.

Configure

$529.88 
2106B2310
(1640)

HONEYWELL  2106B2310

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. High Temperature (150°C with 3rd party performance approval) ATEX

Configure

$595.92 
GDS-48-1-71-06
(343)

GDS  GDS-48-1-71-06

GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with Catalytic Bead for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit). 3-Wire Bridge Output. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others. CSA Certified for Div. 1 Explosion Proof.

Configure

$690.00 
GG-LEL2-CH4
(4137)

CALIBRATION TECHNOLOGIES  GG-LEL2-CH4

CTI GG-LEL2 Combustible Catalytic Bead Gas Detector Transmitter (0-100% LEL) for Methane (CH4), Hydrogen (H2), Propane (C3H8), N-Butane (C4H10), Ethane (C2H6), Ethylene (C2H4), N-hexane (C6H14) or N-pentane (C5H12). 4-20 mA output, 24VDC power supply. Explosion proof Copper-free aluminum enclosure for Class l, Div 1, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved. Optional Relay output.

Configure

$691.65 
EX-_GENL-100L-O
(6021)

MACURCO  EX-GENL-100L-O

Macurco Ex Series Explosion Proof Catalytic Bead Gas Detector for detection of Combustible Gases 0-100%LEL. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1. Optional calibration to Methane, Propane, Pentane, Methanol, Hydrogen, Ethylene, Acetone, Butanol, Butane, Benzene and other combustibles.

Configure

$935.00 
965-525420-100
(5006)

DETCON  965-525420-100

Detcon MicroSafe FP-524D Smart gas detection Sensor designed to detect and monitor combustible gases with range 0-100% LEL using matched-pair catalytic bead sensor technology. Aluminum Junction Box. 4-20mA output. LED Display. Explosion Proof. IP66. CSA and ISA Approved for Class I, Division 1, Groups B, C, & D.

SPXCDULNFX
(658)

HONEYWELL  SPXCDULNFX

Honeywell XCD Sensepoint Gas Detector, CATALYTIC BEAD combustible 0-100% LEL (Lower Explosive Limit) Methane CH4 (natural gas) with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%, can be calibrated to several other combustible gases. UL/CSA Class I Division 1 or ATEX IECEx available.

Configure

$1,055.75 
TMII-00-00-00/48-71-06/0-0
(1671)

GDS  TMII-00-00-00/48-71-06/0-0

GDS TRANSMAX II Gas Detector with Local DELDRIN sensor head configured for Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit), with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU, 4-20mA output transmitter. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others.

Configure

$1,110.00 
967-521520-100
(5005)

DETCON  967-521520-100

Detcon FP-700 non-intrusive Smart Sensor designed to detect and monitor combustible gases with range 0-100% LEL using catalytic bead sensor technology. Aluminum or Stainless Steel Junction Box. 4-20mA and Modbus RS-485 outputs. LED Display. Explosion Proof. IP66. CSA, ATEX, CE and SIL2 Approved.

5100-02-IT-A1-01-0-0
(3070)

SIERRA MONITOR  5100-02-IT-A1-01-0-0

Sierra Monitor 5200-02-IT Combustible 0-100% LEL Gas Leak Detector (Catalytic Bead) for methane and others gases. ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups B, C, D.

Configure

$1,273.63 
DG-TX7-17DG-XXC-X0
(6056)

SIMTRONICS  DG-TX7-17DG-XXC-X0

Simtronics MultiXplo DG-TX7 Intelligent Flammable Catalytic Bead Gas Detector for Combustibles: Methane (CH4), Propane (C3H8) or Butane (C4H10) 0-100% LEL. Stainless Steel housing with integral display. Configurable output. IP66. ATEX and IECEx approvals.

966-524520-100
(6100)

DETCON  966-524520-100

Detcon FP-624D Combustible 0-100% LEL Smart Sensor with catalytic bead. Includes detector in stainless steel housing, base connector board, explosion proof enclosure, splashguard, 4-20 mA output, RS-485 serial communication and 3 alarm relays. IP66. CSA approval for Class I, Division 1, Groups C & D.

XNXUTAVNNCB1
(852)

HONEYWELL  XNXUTAVNNCB1

Honeywell XNX Universal Gas Detector Transmitter including MPD CATALYTIC BEAD sensor combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, INMETRO

Configure

$1,377.63 
GMII-00-000-00/01-071-06/0-0
(557)

GDS  GMII-00-000-00/01-071-06/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head configured for Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit), 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others.

Configure

$1,440.00 
C2-48-071-06/00-000-00/0-0-0-0-0/0-0
(383)

GDS  C2-48-071-06/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local DELRIN sensor head with integrated Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others.

Configure

$1,845.00 
GMCX-01-71-06/00-00-00/0
(3308)

GDS  GMCX-01-71-06/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit), QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others.

Configure

$1,870.00 
GMIIx-00-000-00/01-071-06/1-0900
(1857)

GDS  GMIIx-00-000-00/01-071-06/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head with Catalytic Bead sensor calibrated for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit). A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others.

Configure

$2,008.43 
Page: 1 | 2 | All