Honeywell Ethylene Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for LEL, 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485 and HART. Ethylene calibration with dust barrier, weather housing, deluge/heat shade, configured as current source output. Optional remote gassing cell.

Part# with Options:        2108N4101N
Price with Options:        1,686.39

Options:    

Remote Gassing Cell
(1) Remote Gassing Cell for Honeywell Optima Plus
HART Output
(2) HART Output for Honeywell Optima Plus
Certification
(3) Certification for Honeywell Optima Plus
Calibration (UL)
(4) Special Gas Curves for Honeywell Ethylene Optima Plus 3 (100% LEL) UL
Please select one curve only
Calibration (ATEX)
(5) Standard Gas Curves for Honeywell Ethylene Optima Plus (ATEX/SAA)
Please select one curve only

  Availability In Stock  ]

Standard configurations typically available in In Stock:
2108N4101N-2108D3225    2108N4111N-2108D3225

it also includes Dust Barrier 2108B0259, Deluge and Heat Shade 2108D0275, Weather housing 2108B0276, fully assembled and tested as a complete unit.

Largest selling point IR hydrocarbon gas detector in the world.

Advanced infrared point gas detector

FEATURES

Why Searchpoint Optima Plus is the right choice...
  • The proven strengths of the original Searchpoint OPTIMA design
  • Experience gained from over 30,000 units installed worldwide
  • The latest technology and techniques used to develop the successful Sieger open path gas detector, the Searchline Excel
  • Improved reliability
Why Infrared?
  • Failsafe operation
  • Fast speed of response
  • Reduced routine maintenance
  • Immune to catalytic poisons
  • Long operating life
  • Works in inert atmospheres
Why Searchpoint Optima?
  • Can detect a wide range of hydrocarbon gases including solvents
  • Increased reliability with no moving parts
  • Increased stability from self compensating optics
  • Immune to long term component drift
  • Remote functional gas test facility
  • Certified for North American and European Hazardous areas
Why Searchpoint Optima Plus?
  • Increased false alarm rejection with ✔2 SOFTWARE™
  • Increased uptime with contaminated optics warning
  • Dynamic Heating Control ensures condensation free optics
  • No undetected failures
  • Improved diagnostics
  • Integral event logging
  • Reduced power consumption
  • Certified to many hazardous area classification schemes including: European (ATEX), UL, CSA and more
Optics Block

The 4-channel (dual compensated) optics-block is the heart of the Searchpoint OPTIMA PLUS. It is specifically designed to compensate for changes in the external environment similar to 2- channel designs, but also compensates for long term component drift such as infrared sources and detectors. This combined with the de-focussed beam provides the Searchpoint OPTIMA PLUS with the most stable optics design possible.

Searchpoint Optima Plus Specification
Output
Measuring range 4-20 mA sink or source, (Default current source)
Inhibit 1-3 mA (Default 2 mA)
Warning 0-4 mA (Default 4 mA)
Fault 0 mA
Over range 20-21.5 mA (Default 21 mA)
Digital Output Optional Multidrop Modbus RS485 (via DVC/DX100(m))
Material 316 stainless steel
Weight 1.6 kg
Accuracy
Optima PLUS (HC) Baseline < ±1% LEL, 50% FSD <±2% LEL
Optima PLUS (ET) Baseline < ±2% LEL, 50% FSD <±3% LEL
Repeatability < ±2% LEL at LEL 50% FSD
Linearity < 5% FSD
Response time T50 < 4.5 seconds, T90 < 6.5 seconds (for methane, including weather protection)
Operational and certified -40°C to +65°C temperature range
Drift with time and over temperature range -40°C to +65°C
Baseline < ±2% LEL
50% FSD < ±4% LEL
Variation with pressure 0.1% (of reading) per mbar
Power supply 18-32 V (24 V nom) DC, < 4.5 W max
Environmental protection IP 66/67
Diagnostics (and re-calibration) Via certified Hand Held Interrogator
Safety approvals

ATEX,
II 2 G EEx d IIC
   T5 (Tamb -40°C to +55°C)
   T4 (Tamb -40°C to +65°C)
UL/CSA Class 1, Div 1, groups B, C, and D (-40°C to +65°C)
GOST and SAA

Performance approvals EN50054, EN50057, CSA C22.2 152.
EMC compliance EN 50270
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)9027102000

  • ACCESSORIES > HONEYWELL OPTIMAPLUS
    04200-A-1015 Optima duct mounting kit for Honeywell Optima Plus. Use only with ATEX and SAA Versions ..

  • ACCESSORIES > HONEYWELL OPTIMAPLUS
    2104B2381 DX100i XP junction box UL with IS barrier for Honeywell Optima Plus. For ATEX use an XNX transmiter XNXAMAINNNNN ..

  • ACCESSORIES > HONEYWELL OPTIMAPLUS
    2104B2382 DX100M XP junction box UL with MODBUS capability for Honeywell Optima Plus. ..

  • ACCESSORIES > HONEYWELL OPTIMAPLUS
    2108B0259 Dust Barrier for Honeywell Optima Plus. ..

  • ACCESSORIES > HONEYWELL OPTIMAPLUS
    2108B0276 Weather housing for Honeywell Optima Plus. ..

  • ACCESSORIES > HONEYWELL OPTIMAPLUS
    2108D0275 Deluge / Heat Shade for Honeywell Optima Plus ..

  • CALIBRATION KITS > HONEYWELL OPTIMAPLUS
    OPTIMACALKIT Honeywell Optima Plus calibration kit, 3/16" ID Tubing, gas cover, C-10 inlet regulator for Optima Non-RGC (contains 998-100-004, 2108D0258, 998-100-002 (2LPM), W/GAS CELL) -C-10 Calibration gas cylinder not included- ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ETHYLENE :    10 Items found.
6600-8075
(6275)

BACHARACH  6600-8075

Bacharach MGS-550 Industrial Refrigerant Gas Detector with semiconductor sensor for Ethylene (C2H4) 0-2,000 ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. IP66 Housing. CE, UL and CSA Approvals.

Configure

$566.10 
20100014
(6485)

DEGA  20100014

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Ethylene (C2H4) with range 0-10ppm to 0-1500ppm. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$645.12 
30100008
(6514)

DEGA  30100008

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Ethylene (C2H4) with range 0-10ppm to 0-200ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$737.28 
20100108
(6664)

DEGA  20100108

DEGA NB III LCD Gas Detection Transmitter with Electrochemical Sensor for Ethylene (C2H4) with range 0-10ppm to 0-1500ppm. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$829.44 
30100097
(6540)

DEGA  30100097

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Ethylene (C2H4) with range 0-10ppm to 0-1500ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$921.60 
EX-C2H4-100L-O
(6020)

MACURCO  EX-C2H4-100L-O

Macurco Ex Series Explosion Proof Catalytic Bead Gas Detector for detection of Ethylene (C2H4) 0-100%LEL. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$935.00 
30100172
(6541)

DEGA  30100172

DEGA NS II LCD RE Gas Detector with Infrared Sensor for Ethylene (C2H4) with range 0-100% LEL. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$1,013.76 
961-ED0026-100G
(6357)

DETCON  961-ED0026-100G

Detcon DM-100-C2H4 Electrochemical Ethylene (C2H4) 0-100ppm or 0-200ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

967-12ED90-100
(6081)

DETCON  967-12ED90-100

Detcon DM-700-C2H4 Electrochemical "Smart" Ethylene (C2H4) 0-100 ppm or 0-200 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

2108N5101N
(1968)

HONEYWELL  2108N5101N

Honeywell Ethylene Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for LEL. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485 and HART. Ethylene calibration, for use in remote sampling systems, includes flow housing and remote gassing cell, configured as current source output

Configure

$1,969.63