Rc Systems 2100al-0-9067/1p/l0 | Hydrazine | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

RC SYSTEMS   2100AL-0-9067/1P/L0

SKU# (1825)



RC SYSTEMS 2100AL-0-9067/1P/L0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
RC Systems SenSmart 2100 2 wire 4-20 mA Loop Powered gas detector for Hydrazine (N2H4) with range 0-1 or 0-2 ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20 mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof). Suitable for Class I Div 2 (Non-Incendive).

DISPLAY   4-20 mA   CSA   UL   DIV 1   DIV 2

2100AL-0-9067/1P/L0   
2,520.78

Enclosure Type
Sensor Range
Splash Guard

 3 Weeks  ]
8 Variants of base SKU

The SenSmart 2000 2-Wire 4-20mA Loop Powered Gas Monitor accepts oxygen and many toxic gases by offering a wide variety of electrochemical gas sensors. SenSmart 2000s utilize our popular “GEN 1 smart sensor” proprietary technology to provide sensor recognition and temperature compensation within the SenSmart 2000. Each GEN 1 smart sensor has its’ own non-volatile memory to store records of serial number, born-on date, initial calibration values, engineering units and temperature compensation algorithm.

FEATURES HIGHLIGHT
  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Graphic display shows values,units, trend graph, alarm levels
  • Non-polarized loop powered interface eliminates wiring errors
  • Three flashing Alarm LEDs with Programmable Alarm Levels
  • Real time clock tags alarm and calibration events
  • Non-intrusive, prompted calibration with programmable cal-gas
  • Power-up and post-calibration delays eliminate false alarms
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data and more
  • Fault supervision circuitry detects failed sensor and transmits warning
  • Setup in hazardous area requires only simple magnetic wand

OEM VERSION OF THE GDS CORP GASMAX EC

SPECIFICATIONS
Power Supply10-30VDC at less than 0.75 watts
Display64 x 128 pixel LCD with 30-minute trend, bar graph and engineering units display
Standard OutputStandard 2-wire 4-20mA current sink . Max loop Resistance is 600 ohms with nominal 24VDC power supply
TempElectronics -40°C to +60°C. See Electrochemical Sensor Manual for additional information
HousingAluminum with epoxy paint standard; Optional #316 stainless steel, Optional Ul94 Poly Black Plastic Enclosure
Dimensions(Aluminum) Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
(Poly) Width 5” (127 mm), Height 7” (178 mm), Depth 4” (101 mm) Shipping weight 3 pounds (2 kg)
ApprovalsCSA Certified Div 1 & 2 Groups B, C, D. Suitable for explosion-proof installations
CSA Certified Div 1 & 2 Groups A, B, C, D for Intrinsically safe installations
Warranty5 year limited warranty
For sensor warranty see sensor specifications sheet.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    8 Items found.
10-0203
(7043)

RC SYSTEMS  10-0203

RC SYSTEMS Sensor calibration cup adaptor for stainless steel / aluminum sensor heads



$95.71 
10-0552
(7028)

RC SYSTEMS  10-0552

Sample Draw Flow Cell Barrel Adapter for RC Systems Gen I and Gen II 10-0247 Sensor heads(Series 1000, 2000, 3000, 5000 and 6000) gas detectors) 1/8" NPT ports (1 inlet 1 outlet). Used with ST-44 and ST-48 Transmitters.



$213.06 
CYL-10320260-HDRZ
(1647)

PORTAGAS  CYL-10320260-HDRZ

Calibration Gas Hydrazine (N2H4) simulant 0.7 ppm (Actual content: 20 ppm of Hydrogen Cyanide HCN. Balance Nitrogen N2) 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. Hydrogen Cyanide 20 ppm ~ 0.7 ppm Hydrazine reading by most electrochemical sensors. (Made by Portagas)

Configure

$252.43 
10-9067-1P
(7110)

RC SYSTEMS  10-9067-1P

RC Systems 10-9067/10-9527 Gen I EC Smart Sensor for Series 1000, 2000, 3000 Gas Detectors with ST-48 transmitter, Hydrazine (N2H4) with range 0-1, 0-2

Configure

$1,363.63 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Div 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20 mA input channels board.

Configure

$2,820.78 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Div 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20 mA input channels board.

Configure

$3,525.97 
I-900GHZ-N2H4-0100
(7109)

INTERSCAN  I-900GHZ-N2H4-0100

Interscan GASD 8000 Portable Trace Gas Detector with smart sensor for continuous air sampling of Hydrazine (N2H4). Anodized aluminum enclosure. Includes rechargeable batteries.

Configure

$7,125.00 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. UL and CSA approved for Class I, Div 2, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included. Standard SPDT 5A relays for HORN and FAULT, plus 3 programmable alarm relays included. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. Optional 4-20 mA inputs.

Configure

$12,179.52 
> HYDRAZINE :    4 Items found.
41001AL-0-1034/001P/L0
(7181)

RC SYSTEMS  41001AL-0-1034/001P/L0

RC Systems SenSmart 4100 2-wire 4-20 mA loop powered gas detector for Hydrazine (N2H4) 0-1 or 0-2 ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$2,270.13 
51001AL-0-1034/1P/L0
(7134)

RC SYSTEMS  51001AL-0-1034/1P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrazine (N2H4) 0-1 or 0-2 ppm with GEN2 smart Electrochemical sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays, HART.

Configure

$2,325.97 
31001AL-0-9067/1P/L0
(6881)

RC SYSTEMS  31001AL-0-9067/1P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrazine (N2H4) 0-1 or 0-2 ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20 mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$2,698.70 
6100AL1-0-1034/0001P
(7182)

RC SYSTEMS  6100AL1-0-1034/0001P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrazine (N2H4) 0-1 or 0-2 ppm with 'ST-44' smart transmitter and GEN2 smart Electrochemical sensor. Includes Color TFT Display, 4-20 mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$3,120.78 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.