Honeywell 2108n4100n | Lel Infrared | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   2108N4100N

SKU# (1676)



HONEYWELL 2108N4100N
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20 mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, UL/INMETRO approved (Also available ATEX and CSA). Optional remote gassing cell.

4-20 mA   UL   ATEX   CSA   UL   HART

2108N4100N   
2,229.49

Remote Gassing Cell
HART Output
Certification
Calibration (UL)
Please select one curve only
Calibration (UL)
Please select one curve only
Calibration (UL)
Please select one curve only
Calibration (ATEX)
Please select one curve only

   7 Days  ]

Standard configurations typically available in 7 Days:
2108N4100N-2108D3001    2108N4110N-2108D3001    2108N4000N-2108D3170    2108N4110N-2108D3001
12 Variants of base SKU
2108N4100N contains : 2108B2101N and it also includes Dust Barrier 2108B0259, Deluge and Heat Shade 2108D0275, Weather housing 2108B0276, fully assembled and tested as a complete unit.

Largest selling point IR hydrocarbon gas detector in the world.

Advanced infrared point gas detector

FEATURES

Why Searchpoint Optima Plus is the right choice...
  • The proven strengths of the original Searchpoint OPTIMA design
  • Experience gained from over 30,000 units installed worldwide
  • The latest technology and techniques used to develop the successful Sieger open path gas detector, the Searchline Excel
  • Improved reliability
Why Infrared?
  • Failsafe operation
  • Fast speed of response
  • Reduced routine maintenance
  • Immune to catalytic poisons
  • Long operating life
  • Works in inert atmospheres
Why Searchpoint Optima?
  • Can detect a wide range of hydrocarbon gases including solvents
  • Increased reliability with no moving parts
  • Increased stability from self compensating optics
  • Immune to long term component drift
  • Remote functional gas test facility
  • Certified for North American and European Hazardous areas
Why Searchpoint Optima Plus?
  • Increased false alarm rejection with ✔2 SOFTWARE™
  • Increased uptime with contaminated optics warning
  • Dynamic Heating Control ensures condensation free optics
  • No undetected failures
  • Improved diagnostics
  • Integral event logging
  • Reduced power consumption
  • Certified to many hazardous area classification schemes including: European (ATEX), UL, CSA and more
Optics Block

The 4-channel (dual compensated) optics-block is the heart of the Searchpoint OPTIMA PLUS. It is specifically designed to compensate for changes in the external environment similar to 2- channel designs, but also compensates for long term component drift such as infrared sources and detectors. This combined with the de-focussed beam provides the Searchpoint OPTIMA PLUS with the most stable optics design possible.

Searchpoint Optima Plus Specification
Output
Measuring range 4-20 mA sink or source, (Default current source)
Inhibit 1-3 mA (Default 2 mA)
Warning 0-4 mA (Default 4 mA)
Fault 0 mA
Over range 20-21.5 mA (Default 21 mA)
Digital Output Optional Multidrop Modbus RS485 (via DVC/DX100(m))
Material 316 stainless steel
Weight 1.6 kg
Accuracy
Optima PLUS (HC) Baseline < ą1% LEL, 50% FSD <ą2% LEL
Optima PLUS (ET) Baseline < ą2% LEL, 50% FSD <ą3% LEL
Repeatability < ą2% LEL at LEL 50% FSD
Linearity < 5% FSD
Response time T50 < 4.5 seconds, T90 < 6.5 seconds (for methane, including weather protection)
Operational and certified -40°C to +65°C temperature range
Drift with time and over temperature range -40°C to +65°C
Baseline < ą2% LEL
50% FSD < ą4% LEL
Variation with pressure 0.1% (of reading) per mbar
Power supply 18-32 V (24 V nom) DC, < 4.5 W max
Environmental protection IP 66/67
Diagnostics (and re-calibration) Via certified Hand Held Interrogator
Safety approvals

ATEX,
II 2 G EEx d IIC
   T5 (Tamb -40°C to +55°C)
   T4 (Tamb -40°C to +65°C)
UL/CSA Class 1, Div 1, groups B, C, and D (-40°C to +65°C)
GOST and SAA

Performance approvals EN50054, EN50057, CSA C22.2 152.
EMC compliance EN 50270
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    11 Items found.
2108B0259
(1975)

HONEYWELL  2108B0259

Dust Barrier for Honeywell Optima Plus.



$116.49 
90095187
(6713)

PORTAGAS  90095187

Calibration Gas Propane (C3H8) 50% LEL 1.1% Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$124.51 
90090227
(1313)

PORTAGAS  90090227

Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$124.51 
10624200
(1305)

PORTAGAS  10624200

Calibration Gas Propane (C3H8) 50% LEL 1.06% Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$124.51 
2108D0275
(1980)

HONEYWELL  2108D0275

Deluge / Heat Shade for Honeywell Optima Plus



$229.70 
2108B0276
(1976)

HONEYWELL  2108B0276

Weather housing for Honeywell Optima Plus.



$403.88 
(4709)

HONEYWELL  OPTIMACALKIT

Honeywell Optima Plus calibration kit, 3/16" ID Tubing, gas cover, C-10 inlet regulator for Optima without RGC Remote Gassing Cell (contains 998-100-004 tubing, 2108D0258 gas cover, 998-100-002 C-10 regulator (2LPM), W/GAS CELL), 998-100-003 carrying case. Calibration gas cylinder not included-



$744.63 
XNXUTAINNNNN
(1944)

HONEYWELL  XNXUTAINNNNN

Honeywell XNX Universal Display and Transmitter for IR infrared input compatible with Optima Plus and Excel Open Path sensors, with aluminum alloy LM25 housing (optional stainless steel), 3-wire 4-20 mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs, UL, ATEX or INMETRO certified.

Configure

$1,031.78 
04200-A-1015
(1971)

HONEYWELL  04200-A-1015

Optima duct mounting kit for Honeywell Optima Plus. Use only with ATEX and SAA Versions



$1,366.18 
2108N4000N
(3414)

HONEYWELL  2108N4000N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20 mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, ATEX/IECEx approved (Also available UL/INMETRO and CSA). Optional remote gassing cell.

Configure

$2,229.49 
2104B2351
(1982)

HONEYWELL  2104B2351

Hand Held Interrogator UL SHC-1 Certified (4V0 software) for Optima, Optima Plus and Excel



$2,968.85 
> LEL INFRARED :    29 Items found.
012731-504
(7260)

DET-TRONICS  012731-504

Det-tronics FlexSight LS2000 Infrared gas detection system for combustible hydrocarbon gases 0-5% LEL. 4-20 mA output, HART and RS-485 Modbus communication. 24 VDC. Stainless steel transmitter and receiver. IP66/IP67. NEMA Type 4X. Suitable for Class I, Div 1 and Div 2; Class II, Div 1; Class I, Zone 1; and Zone 1, Zone 2. FM, IEC and SIL 2 Approvals.



 
006300-012
(7250)

DET-TRONICS  006300-012

Det-tronics PIR9400 PointWatch Infrared Hydrocarbon Gas Detector for Methane 0-100% LEL. Diffusion based. 18-30 VDC. 4-20 mA output signal. Explosion proof. IP66. Suitable for Class I Div 1, Div 2, Zone 1 and Zone 2 hazardous areas.



 
116-014048-232
(7230)

AUTRONICA  116-014048-232

Autronica AutroPoint HC200 Infrared IR Hydrocarbon Gas Detector calibrated to methane, propane, ethylene, or butane 0 to 100% LEL. Explosion-proof stainless steel housing. 4-20 mA signal with HART communication. MODBUS and ASCII supported. SIL2, FM/CSA, DEMKO, IECEx and ATEX certified for use in Class I, Div 1 and Div 2, and Zone 1 and Zone 2.



 
P-3033
(6722)

PROSENSE  P-3033

Prosense P-XY35 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$797.94 
PQN-3033-1/2
(6946)

PROSENSE  PQN-3033-1/2

Prosense PQN-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$978.12 
PQD-3033-1/2
(6719)

PROSENSE  PQD-3033-1/2

Prosense PQD-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
1300ALD-109050/100P-L0
(6904)

RC SYSTEMS  1300ALD-109050/100P-L0

RC Systems SenSmart 1300 Infrared (IR) Gas Detector for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide 0-100% LEL or %Vol with 'ST-48' smart transmitter. Infrared (IR) sensor. 3-Wire bridge. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,432.47 
SPXCDULNRX
(659)

HONEYWELL  SPXCDULNRX

Honeywell XCD Sensepoint Gas Detector, Methane (Natural Gas) (CH4) Infrared Sensor combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,484.59 
100-0001-M11-SS-1-2-CH4
(4722)

ESP SAFETY  100-0001-M11-SS-1-2-CH4

ESP Safety SGOES Infrared Gas Detector for measurement of hydrocarbon gases, Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Factory calibrated at 0%, 20%, 50%, and 95% LEL. Analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 3 relays. Includes protective weather cover and mounting hardware. IP66. SIL2 Rated. FM, ABS, IECEx, CE and CSA, Class I Div 1 Approved. Stainless steel construction. T90 response time= < 5 seconds (methane).

Configure

$1,490.40 
100-0008-00-SS-2-2/100-0015-IR-CH4
(4756)

ESP SAFETY  100-0008-00-SS-2-2/100-0015-IR-CH4

ESP Safety Vector 2-channel gas detector controller with smart Infrared IR Plug-In sensor included to detect Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Div 1 certification. Optional 2nd sensor available.

Configure

$1,593.90 
53001AL-0-9050/100P/L0
(7136)

RC SYSTEMS  53001AL-0-9050/100P/L0

RC Systems SenSmart 5300 3-wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with GEN2 smart sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Div 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays, HART.

Configure

$1,809.09 
SPXCDULNPX
(660)

HONEYWELL  SPXCDULNPX

Honeywell XCD Sensepoint Gas Detector, Infrared Sensor for Propane (C3H8), Ethylene (C2H4), Butane (C4H10) & Pentane (C5H12) combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,903.99 
967-215520-100
(2133)

DETCON  967-215520-100

Detcon IR-700-CH Infrared Smart Combustible Sensor Assembly. Designed to detect hydrocarbon gases 0-100% LEL. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water-Proof, Corrosion-Proof and Vibration-Proof. Optional aluminum or stainless steel junction box. Gases: Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, Gasoline Vapor, Diesel Fuel Vapor, Jet Fuel Vapor Optional Alarm Relays, HART.

33001AL-0-9050/100P/L0
(6898)

RC SYSTEMS  33001AL-0-9050/100P/L0

RC Systems SenSmart 3300 3 wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20 mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,181.82 
PIRECLA11A1BT2
(7027)

DET-TRONICS  PIRECLA11A1BT2

Det-tronics PointWatch Eclipse PIRECL Infrared Gas Detector for detection of Hydrocarbons (methane, propane, ethylene, butane) 0 to 100% LFL. Diffusion based. 4-20 mA signal with HART and RS-485 serial communication. Optional relay output. Explosion-proof and stainless steel housing. 24 Vdc. Certified for use in Class I, Div 1 and Div 2. FM, CSA, ATEX, IECEx, DNV/MED, and INMETRO certifications.

XNXUTAVNNIF1
(1225)

HONEYWELL  XNXUTAVNNIF1

Honeywell XNX Universal Gas Detector Transmitter with MPD-AMIF1 IR Infrared sensor for %LEL Propane (C3H8) 0-100% LEL or Methane (CH4) 0-100% LEL and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20 mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional Alarm Relays, Modbus, Fieldbus. *** Detector will be provided as two separate items: XNX transmitter & MPD sensor head, to be assembled by the end user ***

Configure

$2,390.83 
GDS-IR-1-118-0
(1742)

GDS  GDS-IR-1-118-0

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Industrial Process Hydrocarbons (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated. Suitable for applications in the harshest of environments. Available gases: Propylene (C3H6), Acetylene (C2H2), Methane (CH4), Ethylene (C2H4), Isopropyl Alcohol (C3H8O), Acetone (C3H6O), p-Xylene (C8H10), MEK (C4H8O) adn Styrene (C8H8).

Configure

$2,490.00 
GDS-IR-1-110-0
(436)

GDS  GDS-IR-1-110-0

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Combustibles LEL (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated. Suitable for applications in the harshest of environments. Available gases: Methane (CH4), Propane (C3H8), Isobutane (C4H10), Pentane (C5H12), Cyclopentane (C5H10), n-Butane (C4H10), Ethanol (C2H6O), Methanol (CH4O), Hexane (C6H14), Jet-A, Diesel and Gasoline.

Configure

$2,490.00 
XNXUTAVNNIV1
(2141)

HONEYWELL  XNXUTAVNNIV1

Honeywell XNX Universal Gas Detector Transmitter including MPD-AM1V1 IR Infrared sensor combustible 0-5% Vol 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). Backlit LCD Display, HART over 4-20 mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional Alarm Relays, Modbus, Fieldbus. *** Detector will be provided as two separate items: XNX transmitter & MPD sensor head, to be assembled by the end user ***

Configure

$2,499.45 
GM/BX-1-R0100/0
(7293)

GDS  GM/BX-1-R0100/0

GDS GASMAX BX Gas Detector for Hydrobarbons 0-100% LEL, GDS-IR Sensor, 3-wire. Includes 4-20mA analog output and optional 3X isolated 5A alarm relays and MODBUS interface. TFT backlit display. CSA Class I Div 1. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Exane, Jet-A, Diesel, Gasoline, Isopropyl Alchohol and others.

Configure

$2,530.00 
Page: 1 | 2 | All