Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (1545)

HONEYWELL  IR-F9-R410a-1000-N1

$1,126.74     Availability: 4 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



HONEYWELL IR-F9-R410a-1000-N1
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R410a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

HA# M-700075

Part# with Options:        IR-F9-R410a-1000-N1
Price with Options:        1,126.74

Options:    

Range
(1) PPM Range for Manning IR-F9 (R134a)
Enclosure
(2) Enclousure type for Manning IR-F9
ATMOS
(3) ATMOS enviro-adaptive technology for refrigerated areas or outdoors (IR-F9) w SH
ATMOS Technology allows for operation down to -60°F (-50°C) and in condensing humidity environments or during washdown (super heat)
Output Plug
(4) Honeywell Manning Optional output

  Availability 4 Weeks  ]

The industrial refrigeration industry is changing rapidly. The manufacture of R-22 and other HCFCs are being phased out, and manufacturers of cooling systems are introducing new equipment that runs on 407a, 422d, 410a, NH3 and CO2. In step with these changes, EPA fines have escalated for anyone venting ozone-depleting gases. What’s your best move? With Honeywell Analytics, you can green the environment—and green your bottom line.

Honeywell Analytics Infrared monitoring solutions are designed to help your plant operate more efficiently and cost effectively. Unlike sample draw systems which take longer to pinpoint a gas leak, our diffusion sensing technology cuts downtime and the cost of expensive refrigerant replacement. Other technological advantages include flexible standalone or networkable configurations, long operating life expectancy (10+ years); fewer calibration requirements; self-monitoring SensorCheck technology; guaranteed EPA compliance; and accurate, reliable response to all refrigerant gases used in industrial or commercial processes.

Refrigerant Specific

  • Rapid response to refrigerants including R-410a
  • Internal monitoring of 4-20 mA loop circuitry continuously Diffusion-Design Sensor
  • Has no moving parts and doesn’t require pumps or filters
  • All points of detection can be monitored continuously at an affordable cost

Versatility

  • Can be used with any Honeywell Analytics readout
  • Standard range of 0-3,000 ppm, can be rescaled for lower trip points
  • Provides a linear output of 4-20 mA as a function of refrigerant concentration
  • Simple, real-time calibration eliminates maintenance downtime
  • Automatically adapts to fluctuating temperatures

Long-Lasting Performance

  • Unique internal reference channel compensates for dust particles, source degradation, humidity and temperature fluctuation, food odours, chemical cleaners, etc.

ATMOSTM Technology

  • Allows for operation down to -60°F and in condensing humidity environments or during washdown
  • Automatically adapts to its environment and provides accurate and reliable performance under the harshest conditions

Applications

  • Banana and Produce Rooms
  • Beverage Plants
  • Chemical Plants
  • Confined Space Entry
  • Food Processing
  • Gas Bottling Plants
  • Ice Rinks
  • Product Coolers
  • Rack Houses
  • Refrigeration Systems
  • Supermarkets
  • Wineries

SensorCheckTM Technology

  • Checks operating parameters of sensors and sends a notification output signal if an anomaly is identified
  • Tests the sensor every 24 hours for electrical viability
  • Indication can be detected by a Manning gas monitor or PLC

Housing

  • High-mass metal bench provides structural and thermal stability and greater immunity to vibration
  • Superior EMI/RFI shielding

General Specification
Use Infrared (diffusion) type sensor that works in conjunction with any Honeywell Analytics Manning readout or alarm unit. This sensor platform can detect either Ammonia, Carbon Dioxide, or a number of refrigerant gases
Common Operation
Gases Monitored R-410a
Gas Sampling Diffusion method with no moving parts, real time continuous monitoring of all points
Output Linear 4-20 mA output into a load resistor of 500 ohm maximum
Accuracy +/- 3% full scale
Repeatability +/- 1% full scale
Operational
Humidity 0-100% RH (condensing)
Operating Temperature -40°C to +60°C / -60°F to +140°F
Storage Temperature -28°C to +60°C / -20°F to +140°F
Common Module
Cable Recommendation Three conductor, stranded shielded cable with drain wire, all enclosed in a vinyl jacket. For cable runs up to 200 feet, use 18# AWG (Belden #8770 or equivalent).
Power Source 24 Volts DC regulated, 1.2 amp max.
Repeatability +/- 1% full scale
Sensor Specifications
Response Time T90 = 10 seconds with full-scale calibration gas @ .75 litres/min. flow rate
Ranges 0-1,000 ppm, 0-3,000 ppm
Sensor Viability Test SensorCheck, an internal microprocessor determines the sensor’s electrical viability every 24 hours. If the viability test fails a 0.5 mA signal will indicate a fault. An internal light will show if a sensor is dried up or disconnected.
Enclosure 16 gauge painted steel or stainless steel. NEMA 4, UL 508 listed, CSA certified for use with industrial control equipment.
Weight 4.4 lbs.
Export Info
Harmonized Tariff Code (HTC)9027102000

  • MULTI-POINT CONTROLLERS > 1-CHANNEL
    2306B1000 Zareba Unipoint simple DIN rail mounted 1-channel controller with 2 wire 4-20mA, 3 wire 4-20 mA , 3 alarm relays and built-in audiovisual alarms. Flexible and low cost solution to incorporate toxic or oxygen gas detection into control and gas detection sy ..

  • MULTI-POINT CONTROLLERS > HIGH DENSITY MODBUS
    AA96D-DLC Honeywell Manning AirAlert 96d Multi-Channel gas monitoring system for continuos monitoring and control of toxic gases, combustible gases and oxygen hazards. Supports up to 96 addressable devices, any combination of Honeywell Analytics gas detectors (Mann ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> REFRIGERANTS :    41 Items found.
6302-0300
(6241)

BACHARACH  6302-0300

Bacharach MGS-410 Gas Detector Transmitter with semiconductor sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-5000ppm measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R600A, R290, R600 or HC12a. Mobile App Bluetooth Interface.

6302-0101
(6240)

BACHARACH  6302-0101

Bacharach MGS-410 Gas Detector Transmitter with semiconductor sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-1000ppm measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R134A, R404A, R407A, R410A, R22, R507A, R407C, R407f, R-1234ze, R32, R448A, R452A, R513A, R434A, R450A, R1234yf, R514A, R452B, R454A, R422, R422D, R427A, R449A or R454C. Mobile App Bluetooth Interface.

Configure

$216.00 
0019-8106
(4023)

BACHARACH  0019-8106

Bacharach Tru Pointe Portable Refrigerant Leak Detector for All CFC, HCFC and HFC Refrigerants. Battery Powered. User-selectable low or high sensitivy mode. Audible and visual indicators. CE Mark approved.



 
6302-1300
(6251)

BACHARACH  6302-1300

Bacharach MGS-450 Gas Detector Transmitter with semiconductor sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-5000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R600A, R290, R600 or HC12a. Mobile App Bluetooth Interface.

6302-1101
(6250)

BACHARACH  6302-1101

Bacharach MGS-450 Gas Detector Transmitter with semiconductor sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-1000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R134A, R404A, R407A, R410A, R22, R507A, R407C, R407f, R-1234ze, R32, R448A, R452A, R513A, R434A, R450A, R1234yf, R514A, R452B, R454A, R422, R422D, R427A, R449A or R454C. Mobile App Bluetooth Interface.

Configure

$252.00 
6302-4101
(6260)

BACHARACH  6302-4101

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) electrochemical sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-1000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R134A, R404A, R407A, R410A, R22, R507A, R407C, R407f, R-1234ze, R32, R448A, R452A, R513A, R434A, R450A, R1234yf, R514A, R452B, R454A, R422, R422D, R427A, R449A or R454C. Mobile App Bluetooth Interface.

Configure

$373.50 
6302-4300
(6261)

BACHARACH  6302-4300

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) semiconductor sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-5000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R600A, R290, R600 or HC12a. Mobile App Bluetooth Interface.

RD-6
(4063)

MACURCO  RD-6

MACURCO RD-6 line voltage Refrigerant (REF) 0-1000 ppm Gas Detector controller and transducer for R-22, R-134A, R-404A, R-407C and R-410A. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. ETL Listed to UL 61010-1. Long life solid state sensor.

Configure

$375.06 
RD-12
(4062)

MACURCO  RD-12

MACURCO RD-12 line voltage Gas Detector, controller and transducer for Refrigerants (REF) 0-1,000ppm including R-22, R-134A, R-404A, R-407C and R-410A. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1. Long life solid state sensor.

Configure

$383.34 
0019-8040
(4011)

BACHARACH  0019-8040

Bacharach Informant 2 Leak Detector Kit for Refrigerants. Quick Change Sensors. Audible Indicator. Dual LED Displays. Comes with color-coded probe tips, instruction manual, 4 AA batteries, 5 filters and a soft carrying case. CE Mark and UL Approved for Class 1, Div 1 Group D.



 
6302-0052
(6236)

BACHARACH  6302-0052

Bacharach MGS-410 Gas Detector Transmitter with catalytic sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-100% LEL measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R600 or R290. Mobile App Bluetooth Interface.

Configure

$445.50 
0019-8200
(4024)

BACHARACH  0019-8200

Bacharach Tru Pointe IR Infrared Refrigerant Leak Detector for CFC, HCFC, HFC and HFO-1234yf refrigerants. Compact Size. LED bar graph. Visual and audible alarms. Rechargeable lithium ion battery. Rugged housing. SAE J1627, SAE J2791, SAE J2913, CE (pending) and EN 14624 Approvals.



 
6302-1052
(6246)

BACHARACH  6302-1052

Bacharach MGS-450 Gas Detector Transmitter with catalytic sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-100% LEL measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R600 or R290. Mobile App Bluetooth Interface.

Configure

$481.50 
0019-8043
(4014)

BACHARACH  0019-8043

Bacharach Informant 2 Leak Detector Deluxe Kit for Refrigerants. Quick Change Sensors. Audible Indicator. Dual LED Displays. Comes with color-coded probe tips, protective rubber boot, flashlight, instruction manual, 6 AA batteries, 5 filters and a hard carrying case. CE Mark and UL Approved for Class 1, Div 1 Group D.



 
6600-8041
(6272)

BACHARACH  6600-8041

Bacharach MGS-550 Industrial Refrigerant Gas Detector with semiconductor sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-1000ppm or 0-5000ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R32, R134A, R404A, R407A, R407C, R407F, R410A, R422A, R422D, R427A, R507, HFO1234YF, HFO1234ZE, R290, R600, R448A, R449A, R452A, R513A.

Configure

$566.10 
6600-8055
(6273)

BACHARACH  6600-8055

Bacharach MGS-550 Industrial Refrigerant Gas Detector with semiconductor sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-10000ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R32, R134A, R404A, R407A, R407C, R407F, R410A, R422A, R422D, R507, HFO1234ZE.

Configure

$566.10 
3015-8004
(4029)

BACHARACH  3015-8004

Bacharach H-10 Pro Universal Refrigerant Leak Detector for all halogen-based, non-flammable CFC, HFC and HCFC regrigerants. Ultra-sensitive detection. Rechargeable battery. LED and audible buzzer indicators. CE Mark Approved.



 
6302-4052
(6256)

BACHARACH  6302-4052

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) catalytic sensor for Refrigerant Gases (HFC, CFC, HCFC) 0-100% measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R600 or R290. Mobile App Bluetooth Interface.

Configure

$603.00 
6401-0500
(4509)

BACHARACH  6401-0500

Bacharach MGS-250 Infrared Gas Detector Transmitter for Halocarbon (0-3500ppm). Long-life and non-dispersive sensor. Modbus RTU interface. User selectable analog output (4-20mA, 0-5V, 1-5V, 0-10V or 2-10V). LED display, audible and visual alarms. CE and UL/CSA/IEC/EN 61010-1 Approved.



$737.10 
0402148
(6528)

DEGA  0402148

DEGA NS II Gas Detection Transmitter with Semiconductor Sensor for refrigerants R134A, R401A, R404A, R407C, R32, R410A, R12, R22 with range 0-5000ppm. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$820.12 
Page: 1 | 2 | 3 | All