Gas Leak Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (146)

GDS  GMII-01-022-05/00-000-00/0-0

$1,545.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS GMII-01-022-05/00-000-00/0-0 (1)
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Literature

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured for Ethylene Oxide EtO (C2H4O) with range 0-50 to 0-200 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Part# with Options:        GMII-01-022-05/00-000-00/0-0
Price with Options:        1,545.00

Options:    

Sensor Head (E-chem channel)
(1) Sensor Head for GDS GMII (non-reactive gases)
Gas Range
(2) Gas Range for GDS (0-50 to 0-100) EtO
Channel 2
(3) Channel 2 option for GDS GasMax II
Output Options
(4) Output Options for GDS GMII
Enclosure
(5) Stainless Steel Enclosure for GDS
Tag
(6) Tag for GDS
Remote JBox
(7) Remote JBox for GDS GasMax II
MODBUS JBox
(8) MODBUS JBox for GDS GasMax II
Duct Mount
(9) Duct Mount for GDS GasMax II (Channel 1)
Cal Marker
(10) Cal Marker for GDS GASMAX II

  Availability 2 Weeks  ]

The GASMAX II gas monitor delivers the latest in toxic & combustible gas detection technology, reliability and ease of use.

Widest Variety of Available Sensors

Built-in dual channel electronics allow the GASMAX II to support any GDS Corp sensor or any combination of one toxic and one combustible (bridge-type) sensor. GDS Corp Smart Sensors enhance this capability by maintaining their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX II constantly tracks sensor performance and calculates an estimate of sensor life remaining.

Advanced User Interface

The highly visible backlit display and high intensity alarm LEDs constantly show alarm status, calibrated engineering values and programmable tag name; a trend screen shows alarm levels and the most recent 30 minute data values. An internal real-time clock and event log time-stamp calibration and alarm events for later review. A menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Flexible Output Options

In addition to standard dual 4-20mA current loop outputs, an optional dual isolated 4-20mA output board or an RS-485 two-wire MODBUS® interface with three 5A SPDT relays are available to communicate with controllers or drive local alarm indicators. When used with the C1 Protector controller’s MODBUS master port, multiple GASMAX II monitors can be daisy-chained up to 500m to minimize wiring.

Reliable

Available in both single and dual channel models, the GASMAX II is CSA and ATEX certified for use in Class I, Div 1 explosion proof installations. For low temperature applications, an Arctic Monitor option add thermostatically controlled heaters to enable operation as low as –55°C ambient.

FEATURES

  • CSA Certified for Class I, Div 1 explosion-proof installations
  • Monitor both toxic sensors and LEL with one detector
  • Graphic display shows values, units, trend graph, alarm levels
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Backlit display for better visibility in low light conditions
  • Options for 3x 5A alarm contacts, isolated 4-20mA and MODBUS®
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand

GASMAX II SPECIFICATIONS
Power Input: 10-30VDC at < 3 watts with relay board. Additional power (4W peak) required for Arctic Monitor option.
Display Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and eunits.
Electrochemical Sensor Input Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors
Bridge Type Sensor Input Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead. Can be converted to 4-20mA input for use with GDS-49 or other standard 4-20mA source.
Standard Output Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Optional Output #1 Dual 1500CMV isolated 4-20mA current source. Max loop R is 650 ohms with nominal 24VDC.
Optional Output #2 Three Form C Relays 5A @ 30VDC / 240VAC plus RS-485 2-wire MODBUS® slave interface
Temp -25°C to +65°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel opt
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D. Suitable for XP nstallations
ATEX Certified EX II 2 G EEx d IIB + H2 T5
Warranty 2 years from date of purchase on electronics and one year on sensors.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > GDS ELECTROCHEMICAL SMART
    10-9522-R05 Electrochemical Smart Sensor configured for Ethylene Oxide (C2H4O) with range 0-50/0-200 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMA ..

  • ACCESSORIES > GDS POPULAR ACCESORIES
    10-0203 GDS Sensor calibration cup for stainless steel / aluminum sensor heads ..

  • CALIBRATION GAS GDS > ETHYLENE OXIDE
    1200-0594 GDS Gas Detector Calibration Gas Cylinder Ethylene Oxide (ETO) 50ppm. Balance Air. 58L Aluminium Cylinder. ..

  • CALIBRATION KITS GDS > ETHYLENE OXIDE
    1200-0595 GDS Gas Detector Calibration Gas Kit Ethylene Oxide (ETO) 50 ppm. Balance Air. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ETHYLENE OXIDE :    19 Items found.
M001-0012-000
(5997)

MPOWER  M001-0012-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ethylene Oxide (ETO) 0-100ppm or 0-200ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.

Configure

$298.00 
20100087
(6497)

DEGA  20100087

DEGA NB III Gas Detection Transmitter with Infrared Sensor for Ethylene Oxide (C2H4O) with range 0-100% LEL. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$460.80 
G02-BJ10-100
(3027)

RAE  G02-BJ10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Ethylene Oxide (EtO) 0-100 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$511.10 
0019-7063
(4018)

BACHARACH  0019-7063

Bacharach Leakator 10 Combustible Gas Leak Detector for Ethylene Oxide (ETO). Includes carrying case, gas sensor, flexible probe, and instruction manual. Low maintenance and Easy to use. Up to 30 hours of continuos operation. ABS Housing. CE Mark and UL approved for Class 1 Div 1 Groups A, B, C and D.



 
BWS_-E-Y
(6386)

BW  BWS-E-Y

BW Solo Serviceable Single-gas Detector for Ethylene oxide (ETO) 0-100 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$548.25 
20100017
(6486)

DEGA  20100017

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Ethylene oxide (C2H4O) with range 0-10ppm to 0-1000ppm. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$645.12 
364-455-02-365-710-11
(6152)

DELPHIAN  364-455-02-365-710-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ethylene Oxide (ETO) 0-10 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$700.80 
30100011
(6518)

DEGA  30100011

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Ethylene Oxide (C2H4O) with range 0-10ppm to 0-1000ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$737.28 
20100111
(6665)

DEGA  20100111

DEGA NB III LCD Gas Detection Transmitter with Electrochemical Sensor for Ethylene oxide (C2H4O) with range 0-10ppm to 0-1000ppm. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$829.44 
30100100
(6542)

DEGA  30100100

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Ethylene Oxide (C2H4O) with range 0-100ppm to 0-1000ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$921.60 
30100170
(6543)

DEGA  30100170

DEGA NS II LCD RE Gas Detector with Infrared Sensor for Ethylen Oxide (C2H4O) with range 0-100% LEL. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$1,013.76 
GM/EC-01-22-05
(134)

GDS  GM/EC-01-22-05

GDS GASMAX/EC 2-Wire Gas Detector with backlit LCD display and local stainless steel sensor head explosion proof (XP) configured for Ethylene Oxide EtO (C2H4O) with range 0-50 to 0-200 ppm, 4-20 mA output transmitter.

Configure

$1,375.00 
961-EJ0026-100G
(6358)

DETCON  961-EJ0026-100G

Detcon DM-100-C2H4O Electrochemical Ethylene Oxide (C2H4O) 0-100ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

967-12EJ90-100
(6082)

DETCON  967-12EJ90-100

Detcon DM-700-C2H4O Electrochemical "Smart" Ethylene Oxide (C2H4O) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

GDS-IR-1-127-1
(1741)

GDS  GDS-IR-1-127-1

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Ethylene Oxide (ETO) with range 0-50% LEL (0-1.5% Vol), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP).

Configure

$1,890.00 
GM/ECx-01-22-05-1-0900
(1820)

GDS  GM/ECx-01-22-05-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (XP, IS) configured for Ethylene Oxide (C2H4O) with range 0-50 to 0-200 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$1,925.00 
GMCX-01-22-05/00-00-00/0
(3296)

GDS  GMCX-01-22-05/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Ethylene Oxide EtO (C2H4O) with range 0-50 to 0-200 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,040.00 
GMIIx-01-022-05/00-000-00/1-0900
(1843)

GDS  GMIIx-01-022-05/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head configured for Ethylene Oxide (C2H4O) with range 0-50 to 0-200 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,120.90 
GM/TX/01-22-05/00-00-00/1-0900
(3432)

GDS  GM/TX/01-22-05/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head and integrated sensor configured for Ethylene Oxide EtO (C2H4O) with range 0-50 to 0-200 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,165.00