Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx Certified.

Part# with Options:        2106B1413
Price with Options:        735.22

Options:    

Certification/Entry Size
(1) Certification/Entry Size for Honeywell Sieger Sensepoint (NO/SO/NH3)
Gas Range
(2) Gas Range for Honeywell Sieger Sensepoint (0-50 to 0-1000 ppm)
Weather housing
(3) Honeywell Sensepoint (Toxic)
Terminal Housing
(4) Honeywell Sensepoint Terminal Housing/Junction Box
Bartec DE1155 With Continuity Plate 1 X 25mm - 3 X 20mm Entries -ATEX Approved

  Availability 4 Weeks  ]

The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation in potentially explosive atmospheres is made by the use of a suitable Ex d or Ex e approved junction box. The industry standard outputs from Sensepoint are connected to either a choice of Honeywell Analytics’ controllers or 3rd party DCS/ PLC systems. Both flammable and toxic versions are certified to the latest ATEX/ IECEx safety and performance standards.

The flammable detector is available in either % LEL or PPM detection range versions and provides an industry standard mV bridge output. Typical life expectancy is greater than 5 years, after which the detector is simply replaced with a new one.

The toxic detectors are supplied pre calibrated for easy installation and provide an industry standard 2 wire 4-20mA loop output. User connections are Ex d, while front end Intrinsic Safety (IS) design allows for easy exchange of the replaceable sensor while powered. IS design also removes the need for a sinter enabling very fast speed of response and detection of ‘sticky’ gases such as Chlorine and Ammonia.

Sensepoint has proven its suitability across a wide range of demanding applications by delivering high performance and reliability at an affordable cost.

Fit For Purpose
  • Flammable, toxic and Oxygen versions available
  • High performance, low cost
  • Suitable for new and retro fit applications
Proven Sensor Technology
  • SurecellTM electrochemical sensors
  • Poison resistant catalytic bead
  • Fast and reliable
  • Typical 2 to 5 years operational life
ATEX/IECEx Certified
  • Complies with the latest standards
  • Hazardous area approval and performance
  • IP65/67 for use in harsh environments
  • Easy to Use
  • Factory set operation
  • Simple to replace
  • Minimal training required
Range of Accessories
  • Weatherproof cap
  • Flow adaptor
  • Duct mounting kit
  • Collecting cone

Installation Details

Dimensions

Sensepoint Dimensions

Sensepoint flammable and toxic gas detectors are installed using suitable Ex d or Ex e junction boxes. The standard junction box available from Honeywell Analytics includes an earth continuity plate for added RFI protection. The detectors have a choice of mounting thread size to match local preferences.

The Sensepoint range of flammable and toxic detectors are designed for use with a wide range of controllers available from Honeywell Analytics or with 3rd party control equipment accepting their industry standard output signals.

Electrical Connections

Sensepoint Electrical Connections

Ammonia (NH3) 50/1000ppm
Operating Temp -20 to +40˚C
Operating HumidityContinuous: 20 to 90% RH (non-condensing). Intermittent: 10 to 99% RH (non-condensing)
Storage Conditions0 to 25˚C; 30 to 70% RH
Operating Pressure90 to 110kPa
Warm-up Time < 3 minutes
Response Time
T20 -
T50 < 10 secs
T90 < 65 secs
Supply18 to 30VDC; 0.9W maximum
Signal OutputLoop powered 4-20mA
Linearity< 5% fsd
Operating Life18 months (typical)
Storage Life6 months.
Stability (zero)
with time* < ±2% fsd / yr
with temperature** < ±6% fsd
with humidity < ±10% fsd
Stability (span)
with time* < ±20% fsd / yr
with temperature*** < ±20% fsd
with humidity < ±10% fsd
Weight185g
Construc. MaterialsPolyphenylene Sulphide (PPS)
I.P. (NEMA) RatingIP65 (standard), IP67 (with weather protection fitted)
Certification Details
(ATEX/ IECEx)
II 2 GD Ex d ia IIC T4 Gb Tamb -40ºC to +65ºC
tb IIIC A21 IP67 T135ºC Db
Baseefa08ATEX0263X
IECEx BAS08.0070X
Other CertificationsRussian: GOST
Applicable StandardsThis product complies with the relevant CE standards including: EMC to EN50270, Flammable sensor to EN60079-29-1

* = % of range (fsd) per year
** Over operating temperature range
*** = % of applied concentration

Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)9027102000

  • ACCESSORIES > HONEYWELL SENSEPOINT
    00780-A-0100 Sensepoint Terminal Housing - Bartec DE1155 With Continuity Plate 1 X 25mm - 3 X 20mm Entries -ATEX Approved ..

  • ACCESSORIES > HONEYWELL XCD
    02000-A-1635 Honeywell Weather Protection Housing with calibration port / calibration cup for XNX MPD sensors ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> AMMONIA :    57 Items found.
M001-0006-000
(5993)

MPOWER  M001-0006-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ammonia (NH3) 0-100ppm or 0-500ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.

Configure

$348.00 
6302-0026
(6233)

BACHARACH  6302-0026

Bacharach MGS-410 Gas Detector Transmitter with electrochemical or semiconductor sensor for Ammonia (NH3) 0-100ppm to 0-30000ppm measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$472.50 
BWS_-A_-Y
(6382)

BW  BWS-A-Y

BW Solo Serviceable Single-gas Detector for Ammonia (NH3) 0-100 ppm or 0-1000ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$484.50 
TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$509.69 
G02-B810-100
(3023)

RAE  G02-B810-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Ammonia (NH3) 0-100 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$511.10 
TX-12-AM
(3418)

MACURCO  TX-12-AM

MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$511.92 
20100045
(6474)

DEGA  20100045

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Ammonia (NH3) with range 0-100ppm to 0-10000ppm. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$516.10 
6302-1026
(6243)

BACHARACH  6302-1026

Bacharach MGS-450 Gas Detector Transmitter with electrochemical or semiconductor sensor for Ammonia (NH3) 0-100ppm to 0-30000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$528.30 
SPSTAXA1
(1486)

HONEYWELL  SPSTAXA1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Ammonia (NH3) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-50 ppm, 0-1000 ppm)

Configure

$590.59 
30100039
(6506)

DEGA  30100039

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Ammonia (NH3) with range 0-100ppm to 0-10000ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$608.26 
6302-4026
(6253)

BACHARACH  6302-4026

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) electrochemical or semiconductor sensor for Ammonia (NH3) 0-100ppm to 0-30000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$649.80 
SPC3-1120-200US
(2633)

INTEC  SPC3-1120-200US

Intec Controls PolyGard SPC3-1120 Sigle-Point Gas Detector for Ammonia (NH3) 0-300 / 0-1000 ppm, 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified.

Configure

$653.40 
10154079
(4716)

MSA  10154079

MSA ALTAIR 2XP Portable Single Gas Detector with XCell Pulse Technology for Ammonia (NH3) Range 0-100 ppm. Low Alarm 25ppm, High Alarm 50ppm. Stand-alone bump test. Polycarbonate Housing. 25 feet drop test. 95dB audible alarm. Monochrome LCD Display. IP67. cCSAus, ATEX and IEC Approved.



$660.36 
20100139
(6677)

DEGA  20100139

DEGA NB III LCD Gas Detection Transmitter with Electrochemical Sensor for Ammonia (NH3) with range 0-100ppm to 0-10000ppm. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$700.42 
364-455-01-365-761-11050
(6149)

DELPHIAN  364-455-01-365-761-11050

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ammonia (NH3) 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$700.80 
LBW-WATCHMAN-SS
(4486)

COOL AIR  LBW-WATCHMAN-SS

Cool Air LBW-Watchman Ammonia (NH3) 0-1000ppm Leak Detector. 4-20mA analog output. NEMA 4X, UL Listed enclosure. IP66. 24VDC.

Configure

$768.95 
30100128
(6531)

DEGA  30100128

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Ammonia (NH3) with range 0-100ppm to 0-10000ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$792.58 
6600-8019
(6269)

BACHARACH  6600-8019

Bacharach MGS-550 Industrial Refrigerant Gas Detector with electrochemical, catalytic or semiconductor sensor for Ammonia (NH3) 0-100ppm to 0-10000ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. IP66 Housing. CE, UL and CSA Approvals.

Configure

$803.70 
LBW-50-115-SS
(910)

COOL AIR  LBW-50-115-SS

Cool Air LBW-50 Ammonia (NH3) 0-1000ppm Gas Leak Detector. NEMA 4X IP66 enclosure. Alarm, pre-alarm and auxiliary relays. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC

Configure

$878.15 
LBW-50-RLV-115-SS
(914)

COOL AIR  LBW-50-RLV-115-SS

Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed