Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (120)

GDS  GM/EC-01-14-19

DETECTORS / GAS DETECTORS
HYDROGEN

$1,375.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS GM/EC-01-14-19 (1)
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Literature

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (explosion proof ) configured for Hydrogen (H2) with range 0-1% or 0-4% vol. 4-20 mA output transmitter.

Part# with Options:        GM/EC-01-14-19
Price with Options:        1,375.00

Options:    

Sensor Head
(1) Sensor Head for GDS GM/EC
Enclosure
(2) Stainless Steel Enclosure for GDS
Tag
(3) Tag for GDS
Gas Range
(4) Gas Range for GDS (0-2000 ppm, 0-1% to 0-4% vol) Hydrogen sensors

  Availability 2 Weeks  ]

The GASMAX EC single channel gas monitor for toxic or oxygen deficiency ap- plications delivers the latest in loop-pow- ered gas detection technology, reliability and ease of use.

Wide Variety of Available Sensors

The GASMAX EC support all GDS Corp toxic sensors, including oxygen, hydrogen sulfide, chlorine, carbon monoxide and more. In addition, GDS Corp Smart Sen- sors enhance this capability by maintain- ing their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX EC constantly tracks sensor performance and calculates an estimate of sensor life remaining. Built-in fault detection circuity constantly monitors the sensor for correct operation.

Advanced User Interface

The highly visible graphic display and flashing alarm LEDs constantly show alarm status, calibrated engineering values and a programmable tag name, plus a trend screen shows alarm levels and a graph of the most recent 30 minutes.

An internal real-time clock and event log time-stamp up to 300 calibration and alarm events for later review. Taking advantage of the high-resolution graphic display, an easy-to-use menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Three operational levels of security al- low the GASMAX EC to be fully field configurable, partially restricted or com- pletely restricted by way of user ID and access code.

Explosion-Proof or Intrinsically Safe

The GASMAX EC is CSA certified for use in Div 1 & Div 2 hazardous areas and can be installed as Explosion Proof (with stainless steel sensor head) or Intrinsi- cally Safe (with aluminum sensor head) using appropriate wiring techniques and an Intrinsically Safe barrier. See notes on IS installation on back. An ATEX certi- fied version for XP installations is also available.

FEATURES

  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Non-polarized loop powered inter- face eliminates wiring errors
  • Graphic display shows values, units, trend graph, alarm levels
  • Three flashing Alarm LEDs with Programmable Alarm Levels
  • Real time clock tags alarm and calibration events
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibra- tion with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • For combustible applications, see the GASMAX II gas monitor

Note: Sensor Heads 3, 4 and 8 require INTRINSICALLY SAFE (IS) installations in hazardous locations. IS installations require an IS barrier (#10-0263 MTL 7787P+) or equivalent that must be mounted in an area designated as Non-hazardous.

GASMAX EC SPECIFICATIONS
Power Input: 10-30VDC at less than 0.75 watts in 2-wire 4-20mA configuration
Display 64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units display.
Input Accepts microamp-level signals from local or remote GDS Corp toxic or oxygen deficiency sensors
Calibration Range Zero = +/- 15% of range with 0.1% resolution
Span = Gain adjustment of 0.5 to 2.0 with 0.1% resolution
Accuracy +/- 5% of full scale range (typical)
Standard Output Standard 2-wire 4-20mA current sink output. Max loop R is 600 ohms with nominal 24VDC power supply.
Temp -25°C to +60°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel optional
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified Div 1 & 2 Groups B, C, D. Suitable for explosion-proof installations
CSA Certified Div 1 & 2 Groups A, B, C, D. Intrinsically safe.
IMPORTANT: Intrinsically Safe installations require IS barrier #10-0263 (MTL 7787P+) or equivalent.
ATEX Certified EX II 2 G EEx d IIB + H2 T5
Warranty Two years on electronics and one year on sensors from date of purchase
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > GDS ELECTROCHEMICAL SMART
    10-9514-R19 Electrochemical Smart Sensor configured for Hydrogen (H2) with range 0-1% or 0-4% vol. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, ..

  • ACCESSORIES > GDS POPULAR ACCESORIES
    10-0203 GDS Sensor calibration cup for stainless steel / aluminum sensor heads ..

  • BARRIERS > GDS GASMAX II, GASMAX EC GAS MONITOR
    10-0263 GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent ..

  • CALIBRATION GAS GDS > HYDROGEN
    1200-0545 GDS Gas Detector Calibration Gas Cylinder Hydrogen (H2) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder. ..

  • CALIBRATION KITS GDS > HYDROGEN
    1200-0511 GDS Gas Detector Calibration Gas Kit Hydrogen (H2) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • HYDROGEN IN NATURAL GAS > HYDROGEN
    GDS-68XP1/1-14-19/1-0-0 GDS GDS-68XP Process Gas Monitor with Stainless Steel sensor head configured for Hydrogen (H2) in natural gas with range 0-2000 ppm, 0-1% or 0-4% vol. Uses periodic sampling (from 3x per day to 12x per day) to extend sensor life and minimize discharge of ..

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HYDROGEN :    33 Items found.
HD-11
(653)

MACURCO  HD-11

Macurco HD-11 Gas Detector for Hydrogen (H2) 10% LEL. Low voltage and designed for connection to Fire Alarm/Burglary Control Panels, SPDT Alarm and N.C. Trouble Relays. 12-24 VAC or VDC input. Intended for installation buildings in non-hazardous locations such as residences, retail stores, office buildings, and similar facilities.



$243.48 
M001-0018-000
(6329)

MPOWER  M001-0018-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen (H2) 0-1000ppm or 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.

Configure

$298.00 
0401061
(6473)

DEGA  0401061

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Hydrogen (H2) with range 0-100ppm or 0-100%LEL. 4-20mA 3-Wire and RS-485 outputs. IP54.

Configure

$420.33 
0402078
(6515)

DEGA  0402078

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Hydrogen (H2) with range 0-1000ppm or 0-100%LEL High Concentration. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54. ATEX Zone 2.

Configure

$439.88 
0407224
(6550)

DEGA  0407224

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Hydrogen (H2) with range 0-1000ppm or 0-100% LEL. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54. ATEX Zone 2.

Configure

$498.53 
G02-BM10-100
(3028)

RAE  G02-BM10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Hydrogen (H2) 0-1000 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$555.75 
BWS_-R-Y
(6387)

BW  BWS-R-Y

Honeywell BW Solo Serviceable Single-gas Detector for Hydrogen (H2) 0-1000 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$572.00 
SPSTAXG1
(1487)

HONEYWELL  SPSTAXG1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen (H2) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-1000 ppm, 0-10000 ppm)

Configure

$582.25 
GG-H2-EC-2000
(2965)

CALIBRATION TECHNOLOGIES  GG-H2-EC-2000

CTI GasGuard H2 Hydrogen Catalytic Bead Sensor 0-1% (10000 ppm or 25%LEL) for gas leak detection in battery charging rooms, steel industry, refineries and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$661.20 
2106B1416
(1462)

HONEYWELL  2106B1416

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen (H2) (0-1000 ppm to 0-10000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx Certified.

Configure

$713.40 
GDS-49-1-14-08
(163)

GDS  GDS-49-1-14-08

GDS GDS-49 Remote Gas Detector Transmitter with Stainless steel sensor head configured for Hydrogen (H2) with range 0-1000 to 0-5000 ppm. 2-Wire 4-20 mA transmitter.

Configure

$825.00 
GG-H2-EC-10000-EXP
(5978)

CALIBRATION TECHNOLOGIES  GG-H2-EC-10000-EXP

CTI GG-H2-EC-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen (H2) 0-2000 ppm and 0-10000 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$843.90 
EX-H2-100L-O
(6023)

MACURCO  EX-H2-100L-O

Macurco Ex Series Explosion Proof Catalytic Bead Gas Detector for detection of Hydrogen (H2) 0-100%LEL. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$958.38 
SPXCDULNG1
(665)

HONEYWELL  SPXCDULNG1

Honeywell XCD Sensepoint Gas Detector, Hydrogen (H2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66 for hydrogen (H2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 1,000ppm only UL/CSA Class I Division 1 or ATEX IECEx available.

Configure

$1,023.48 
SPXCDULNG2
(5102)

HONEYWELL  SPXCDULNG2

Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen (H2) with Remote Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 1000 ppm. UL/cCSAus Approved for Class I Div 2.

Configure

$1,167.11 
S3KUL2-XNXXSG1SS
(689)

HONEYWELL  S3KUL2-XNXXSG1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN (H2) with electrochemical sensor, 2-wire 4-20mA loop. Optional ranges: 0-1,000ppm ,0-10,000ppm

Configure

$1,285.72 
961-070026-01PG
(6053)

DETCON  961-070026-01PG

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-1%vol Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

961-840026-100G
(6363)

DETCON  961-840026-100G

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-100ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ITRANS2-1L00000
(6295)

OLDHAM  ITRANS2-1L00000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Hydrogen (H2) 0-999 ppm. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

100-0008-A1/100-0015-H2
(4753)

ESP SAFETY  100-0008-A1/100-0015-H2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In Sensor to Detect Hydrogen (H2) 0-4% vol or 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. Explosion-proof housing. IP67. SIL certification.

Configure

$1,401.60 
Page: 1 | 2 | All