Notifier Cmf-300 | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   CMF-300

SKU# (7243)
NOTIFIER CMF-300
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier CMF-300 Addressable Control Module for providing intelligent control panels a circuit for notification. 15-32 VDC. ULC listed.

Please Email us your request for quote   

   4 Weeks  ]
General

The CMF-300(A) Addressable Control Module provides Fire•Lite intelligent control panels a circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the CMF-300(A) to be activated through panel programming, on a select (zone or area of coverage) basis.

LiteSpeed™ is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs.

Features
  • Built-in type identification automatically identifies these devices to the control panel.
  • Internal circuitry powered directly by two-wire SLC loop. The CMF-300(A) module requires power (for horns, strobes, etc.).
  • Integral LED “blinks” green each time a communication is received from the control panel and turns on steady red when activated.
  • High noise immunity (EMF/RFI).
  • The CMF-300(A) may be used to switch 24-volt NAC power.
  • Wide viewing angle of LED.
  • SEMS screws with clamping plates for wiring ease.
  • Direct-dial entry of address: 01– 159 for MS-9600 series panels, 01 – 99 on MS-9200UDLS and MS-9050UD.
Applications

The CMF-300(A) is used to switch 24 VDC audible/visual power.

Construction
  • The face plate is made of off-white heat-resistant plastic.
  • Controls include two rotary switches for direct-dial entry of address setting.
  • The CMF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit.
Operation

Each CMF-300(A) uses one of the module addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/ short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The CMF-300(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits.

Upon code command from the panel, the CMF-300(A) will disconnect the supervision and connect the external power supply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay-isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system.

Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a module and a sensor address.

Agency Listings and Approvals

In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status.

  • ULC: S2424

MMF-300 Specifications
Nominal operating voltage:15 to 32 VDC.
Maximum SLC current draw:6.5 mA (LED on).
Average operating current:350 μA direct poll (CLIP mode), 375 μA group poll (LiteSpeed mode) with LED flashing.
External supply voltage:maximum 80 volts (RMS or DC).
Drain on external supply:2 mA maximum (using internal EOL relay).
EOL resistance:47K ohms.
Temperature range:32°F to 120°F (0°C to 49°C).
Humidity range:10% to 93% non-condensing.
Dimensions:4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box.
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NOTIFIER :    42 Items found.
RTS151KEY
(7241)

NOTIFIER  RTS151KEY

Notifier RTS151KEY automatic remote test station for duct smoke detectors. Includes key and status indicator.



 
MMF-301
(7238)

NOTIFIER  MMF-301

Notifier MMF-301 Addressable Mini-Monitor Module for use in intelligent, two-wire using rotary switches. 15-32 VDC.



 
CRF-300
(7236)

NOTIFIER  CRF-300

Notifier CRF-300 Addressable Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM and MEA Approved.



 
MMF-300
(7242)

NOTIFIER  MMF-300

Notifier MMF-300 Addressable Monitor Module for supervising circuits of dry-contact input devices. Powered by two-wire SLC loop. 15-32 VDC. UL and FM listed.



 
B300-6
(7063)

NOTIFIER  B300-6

Notifier B300-6 Standard 6” Intelligent Base

SMB500-WH
(4022)

NOTIFIER  SMB500-WH

Notifier System Sensor Surface Mount Box



 
SB-10
(6935)

NOTIFIER  SB-10

Notifier SB-10 (Metal) or SB-I/O (Plastic) Surface Backbox for Notifier NBG-10 or NBG-12 pull stations.

B501-WH
(7067)

NOTIFIER  B501-WH

Notifier B501 4” standard European flangeless mounting base. UL/ULC listed.

SPCWL
(7068)

NOTIFIER  SPCWL

Notifier SPCWL Indoor Selectable-Output Speaker for Ceiling Applications (520 Hz). 12- or 24-volt operation. UL, ULC, FM and CSFM approved.



 
FMM-1
(3695)

NOTIFIER  FMM-1

Notifier FMM-1/FMM-101 Series Monitor Module for supervised dry-contact input devices or monitor and power two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.

HWL-LF
(7065)

NOTIFIER  HWL-LF

Notifier HRL-LF or HWL-LF Low frequency wall sounder (520 Hz). Plastic housing. Includes universal mounting plate. NFPA compliance. UL Listed.

B200S-WH
(6928)

NOTIFIER  B200S-WH

Notifier B200S-WH Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. Only compatible with the NFS-320, NFS2-640 and NFS2-3030 operating version with version 15.0 or higher panel firmware.



 
FRM-1
(3694)

NOTIFIER  FRM-1

Notifier FRM-1 Series Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. Two Form-C dry contacts. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
FCM-1
(3236)

NOTIFIER  FCM-1

Notifier FCM-1 Series Addressable Control Module for Notification Appliances (horns, strobes, speakers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
B210LPBP
(4141)

NOTIFIER  B210LPBP

Notifier B210LPBP Flanged Mounting Intelligent Base (10 Pack)



 
FDM-1
(6597)

NOTIFIER  FDM-1

Notifier FDM-1 Series Monitor Module to supervise, monitor and power Style B dry-contact input devices with two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.



 
B200S-LF-WH
(7066)

NOTIFIER  B200S-LF-WH

Notifier BS200S-LF Low Frequency Intelligent, programmable sounder base (520 Hz). Meest NFPA 72.

FCM-1-REL
(4143)

NOTIFIER  FCM-1-REL

Notifier FCM-1-REL(A) Series Releasing Control Module for fire suppresion releasing applications. Reports the panel status as NORMAL, OPEN or SHORT CIRCUIT. Analog communications. FlashScan operation. 15 to 32 VDC. UL, FM and CSFM Approved.



 
BAT-12180-BP
(4140)

NOTIFIER  BAT-12180-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 18 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
PF24V
(3237)

NOTIFIER  PF24V

Notifier PF24V ExitPoint Directional Sounder with Voice Messaging designed for open areas, corridors or stairs. Reduces evacuation times up to 75%. 24VDC. UL, FM, CSFM and MEA Approved.



 
BAT-1270-BP
(6944)

NOTIFIER  BAT-1270-BP

Notifier BAT-1270-BP rechargeable battery. 12VDC. 7 AH. 5-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-12550
(6943)

NOTIFIER  BAT-12550

Notifier BAT-12550 rechargeable battery. 12VDC. 55 AH. Overcharge protected. ABS high-impact case.



 
BAT-12260-BP
(6941)

NOTIFIER  BAT-12260-BP

Notifier BAT-12260-BP rechargeable battery. 12VDC. 26 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
ISO-6
(6934)

NOTIFIER  ISO-6

Notifier ISO-6 Six Fault Isolator Module for Notifier Fire Alarm Control Panels (FACPs). Powered by SLC loop. Class B isolator circuits. UL, FM, CSFM Approved.



 
LDM-32
(6870)

NOTIFIER  LDM-32

Notifier LDM-32 Lamp Driver Module for annunciation and control of NOTIFIER Intelligent Fire Alarm Control Panels. Up to 32 alarm indications. 24 VDC. EIA-485 interface. UL, ULC, MEA, CSFM and FM Listed.



 
BAT-12120-BP
(6940)

NOTIFIER  BAT-12120-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 12 AH. 4-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-1250-BP
(6942)

NOTIFIER  BAT-1250-BP

Notifier BAT-1250-BP rechargeable battery. 12VDC. 5 AH. 10-unit bulk pack, Overcharge protected. ABS high-impact case.



 
XP6-R
(6930)

NOTIFIER  XP6-R

Notifier by Honeywell XP6-R(A) Six Relay Control Module with Form-C Relays. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP6-C
(5122)

NOTIFIER  XP6-C

Notifier XP6-C Six Circuit Supervised Control Module for horns, strobes or bells that require an external power supply. Short-circuit-protection. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP10-M
(3724)

NOTIFIER  XP10-M

Notifier XP10-M Ten Input Monitor Module for intelligent alarm systems. Up to 10 addresable Class B or 5 addressable Class A devices. SLC inputs. Green LED indicators. Flexible mounting options. FlashScan or CLIP operation. UL Listed. CSFM, FM, MEA and MSTM approved.



 
PSE-6
(6924)

NOTIFIER  PSE-6

Notifier PSE-6 (6 amp) or PSE-10 (10 amp) 24 VDC Remote Power Supply Expander with battery charger for 12 or 24 volt alarm control panels (FACP). Up to 7 outputs. UL, ULC, CSFM and FM listed.

APS2-6R
(6938)

NOTIFIER  APS2-6R

Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

BAT-121000
(6939)

NOTIFIER  BAT-121000

Notifier BAT-121000 rechargeable battery. 12VDC. 100 AH. Overcharge protected. ABS high-impact case.



 
NCM-F
(3507)

NOTIFIER  NCM-F

Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

HPFF12
(6600)

NOTIFIER  HPFF12

Notifier HPFF12(E) 12 Amp and 24 Volt Power Supply to extend the power of existing Notification Appliance Circuits (NACs) or provide power for auxiliary devices. 4 NAC and 1 aux outputs. 8 status LEDs. UL, CSFM and FM listed.

KDM-R2
(6932)

NOTIFIER  KDM-R2

Notifier KDM-R2 Keyboard Display Module for CPU2-640. 80 character display and QWERTY programming keypad included.



 
ACPS-610
(6936)

NOTIFIER  ACPS-610

Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

AMPS-24
(6937)

NOTIFIER  AMPS-24

Notifier AMPS-24 Addressable Power Supply for NFS-3030, NFS2-3030 and NCA-2. Charges 7 AH to 200 AH batteries. SLC circuit. UL, ULC, CSFM and FM listed.

LEM-320
(6872)

NOTIFIER  LEM-320

Notifier LEM-320 Loop Expander Module for NOTIFIER’s ONYX Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
LCM-320
(6871)

NOTIFIER  LCM-320

Notifier LCM-320 Loop Control Module for NOTIFIER’s ONYX Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Cookie Notice