Gasdetectorsusa.com:gas Leak And Flame Detectors, Analyzers, Alarm Devices And Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
VOC PID AND TOXIC:    12 Items found.
(220)

GDS  GMII-01-011-06/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Carbon Monoxide (CO) with range 0-300/0-1000 ppm (included).



 
(224)

GDS  GMII-01-015-04/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen Sulfide (H2S) with range 0-50/0-100 ppm (included).



 
(225)

GDS  GMII-01-016-12/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-50 ppm (included).



 
(228)

GDS  GMII-01-019-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Sulfur Dioxide (SO2) with range 0-20/0-100 ppm (included).



 
(231)

GDS  GMII-01-022-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Ethylene Oxide ETO (C2H4O) with range 0-20 ppm (included).



 
(221)

GDS  GMII-03-012-02/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with local aluminun sensor head configured for Chlorine (Cl2) with range 0-5/0-50 ppm (included).



 
(222)

GDS  GMII-03-013-01/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (ClO2) with range 0-1 ppm (included).



 
(226)

GDS  GMII-03-017-12/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Hydrogen Chloride (HCL) with range 0-30 ppm (included).



 
(227)

GDS  GMII-03-018-02/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Hydrogen Fluoride (HF) with range 0-10 ppm (included).



 
(229)

GDS  GMII-03-020-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Ammonia (NH3) with range 0-100 ppm (included).



 
(230)

GDS  GMII-03-021-01/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Ozone (O3) with range 0-1 ppm (included).



 
(6470)

INDUSTRIAL SCIENTIFIC  MX6-00000301

Industrial Scientific MX6 iBrid Multi Gas Detector for up to 6 gases. Detects Oxygen (O2), toxic gases, combustible gases (LEL) and volatile organic compounds (VOCs). Catalitic Bead, Electrochemical, Infrared or PID sensors. Includes Full-color LCD Display and 95dB audible alarm. Concussion-proof overmold. IP64. ATEX, CSA, IECEx, UL & INMETRO Approvals.



Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.