Gasdetectorsusa.com:gas Leak And Flame Detectors, Analyzers, Alarm Devices And Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
INFRARED:    180 Items found.
(4722)

ESP SAFETY  100-0001-M11-SS-C1

ESP Safety SGOES Infrared Gas Detector for measurement of hydrocarbon gases, Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Factory calibrated at 0%, 20%, 50%, and 95% LEL. Analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 3 relays. Includes protective weather cover and mounting hardware. IP66. SIL2 Rated. FM, ABS, IECEx, CE and CSA, Class I Division 1 Approved. Stainless steel construction. T90 response time= < 5 seconds (methane).

Configure

$1,440.00 
(4719)

ESP SAFETY  100-0003-01

ESP Safety IPES-IR/UV Infrared/Ultraviolet Flame Detector for detection of oil and petrochemical product fires. 4.2 to 4.6 microns (infrared) and 180 to 250 nanometers (ultraviolet) ranges. 90 degree field of view. RS-485, Modbus RTU, 4-20mA and relay outputs. Color status LED. Explosion-proof Housing. Designed for Class I, Division 1, Group B, C & D. ATEX certified, SIL3 Rated. Includes protective visor, stainless steel mounting bracket and hardware.

Configure

$1,350.00 
(4756)

ESP SAFETY  100-0008-SS/100-0015-C1

ESP Safety Vector 2-channel gas detector controller with smart Infrared IR Plug-In sensor included to detect Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
(4761)

ESP SAFETY  100-0008-SS/100-0015-C3

ESP Safety Vector 2-channel gas detector controller with smart Infrared IR Plug-In sensor included to detect Propane (C3H8) 0-100% LEL. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
(4746)

ESP SAFETY  100-0015-C1

ESP Safety Sensor Assembly, PGU Infrared IR Plug-In sensor for Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Stainless steel housing, includes weather protective dust cap.

Configure

$690.00 
(4720)

ESP SAFETY  100-0017-01

ESP Safety IPES-IR3 Infrared Flame Detector for detection of combustible vapors gases fires. Sends an alarm only when data from 3 different IR wavelengths detects a flame. RS-485, Modbus RTU, 4-20mA and relay outputs. Tri-Color status LED. Explosion-proof Housing. IP66. Designed for Class I, Division 1, Group B, C & D. ATEX certified, SIL3 Rated. Includes protective visor, stainless steel mounting bracket and hardware.

Configure

$1,805.25 
(4587)

GDS  10-0270-IR

GDS Stainless Steel Duct Mount for GDS stainless steel or aluminum sensor heads can be used to mount the gas detector or remote standard sensor directly into an air duct or plenum for GDS-IR



 
(561)

GDS  10-0271

Sample flow cell assembly for GDS-IR



 
(7183)

RC SYSTEMS  10-0498/100L

RC Systems SenSmart 1300M Infrared IR gas detector transmitter for Hydrocarbons 0-100% LEL or %Vol with high performance harsh environment infrared Millenium sensor-transmitter, 4-20mA output, 10-30 VDC, Stainless Steel casing. CSA certified for Class 1 Div 1 (Explosion Proof). Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Gasoline, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$3,422.07 
(7090)

RC SYSTEMS  10-9050

RC Systems 10-9050/10-9082/10-9550 Gen I Infrared Smart Sensor assembly for Series 1000, 2000, 3000, 5000, 6000 Gas Detectors with ST-44 & ST-48 transmitter, Methane (CH4) 0-100% LEL or 0-100% Volume

Configure

$779.22 
(7103)

RC SYSTEMS  10-9053

RC Systems 10-9032/10-9053/10-9553 Gen I Infrared Smart Sensor assembly for Series 1000, 3000, 5000, 6000 Gas Detectors with ST-44 & ST-48 transmitter, Carbon Dioxide (CO2) IR 0-1.5% or 0-5% Volume

Configure

$779.22 
(262)

GDS  10-9550-R06

Infrared Smart IR LEL Sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
(338)

GDS  10-9551-R06

Infrared Smart IR LEL Sensor with range 0-100% LEL (Lower Explosive Limit) for combustibles (specify). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
(3408)

GDS  10-9552-R06

Infrared Smart IR LEL Sensor configured for Methane by Volume. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
(263)

GDS  10-9553-R02

Infrared Smart IR Sensor configured for Carbon Dioxide CO2 with range 0-5% volume. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
(3409)

GDS  10-9557-R02

Infrared Smart IR Sensor configured for Ethylene Oxide ETO with range 0-3% volume. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
(3373)

GDS  10-9850-R06

Infrared Smart IR LEL Sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit). For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
(3374)

GDS  10-9851-R06

Infrared Smart IR LEL Sensor with range 0-100% LEL (Lower Explosive Limit) for combustibles (specify). For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
(3412)

GDS  10-9852-R06

Infrared Smart IR LEL Sensor configured for Methane by Volume. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
(3381)

GDS  10-9853-R02

Infrared Smart IR Sensor configured for Carbon Dioxide CO2 with range 0-5% volume. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
Page: 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | All


Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.