Simplex Tyco 2099-9XXX non-coded non-addressable manual station. Single or Double action operation. Surface or Flush mounting. High impact polycarbonate housing. Complies with ADA requirements. UL listed.

UL

2099-9754   
Please Email us your request for quote   

Version

   6 Weeks  ]
14 Variants of base SKU
Features Manual fire alarm stations for general purpose applications:
  • Operation complies with ADA requirements
  • Pull lever protrudes when alarmed
  • Break-rod is supplied, use is optional
  • Screw terminals for wiring connections
  • Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets)
Operation types include:
  • Single action
  • Double Action, Breakglass or Push Type
  • Institutional Model, key operated only
  • Optional NO GRIP Single Action Retrofit Kits are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate
  • Optional Local Alarm cover
  • Optional pre-signal and annunciator contacts
Multiple mounting options:
  • Surface or semi-flush with standard boxes or matching Simplex boxes
  • Flush mount adapter kit
UL listed to Standard 38 Operation

Activation of the Simplex single action manual stations requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod which is visible below the pull lever, use is optional. The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication.

Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station.

Double Action Stations (Push Type) require that a spring loaded interference plate, which is marked PUSH, be pushed back to access the pull lever of the single action station.

Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. If the break-rod is used, it must be replaced.

Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch.

Institutional Stations activate by key operation only allowing access for manual alarms to be initiated by authorized personnel. Operation requires key insertion and opening of the station cover.

Single Action Station NO GRIP Retrofit Kit 4099-9805. For applications such as California Building Code, Title 24, which requires "Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist" the model 4099-9805 Retrofit kit provides a more easily operated pull lever compared to standard stations.

Pre-Signal Option activates when the lever is pulled. General alarm initiation requires a key to activate a keyswitch located behind the pull lever.

Station Reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. If the break-rod is used, it must be replaced.

Testing requires physical activation of the pull lever, except for institutional stations.

Specifications
Wire connectionsScrew terminal for in/out wiring, for 18 AWG to 14 AWG wire
UL listed temperature range32°F to 120°F (0°C to 49°C) intended for indoor operation
Humidity rangeUp to 93% RH at 100°F (38°C)
Housing colorRed with white raised lettering
MaterialHousing and pull lever are high impact polycarbonate
Pull lever colorWhite with red raised lettering
Housing dimensions5 in. H x 3 3/4 in. W x 1 in. D (127 mm x 95 mm x 25 mm)
Export Info
Made inMexico
Harmonized Tariff Code (HTC)85311001

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    50 Items found.
NOT-BG-12LX
(7237)

NOTIFIER  NOT-BG-12LX

Notifier NOT-BG12LX Addressable Manual Pull Station, dual-action (requires two motions to activate the station). Surface or Semi-flush mounting. 24a VDC. UL, FM, CSFM and MEA Approved.



 
NBG-12
(6824)

NOTIFIER  NBG-12

NOTIFIER by Honeywell NBG-12 Non-Coded Conventional Manual Fire Alarm Pull Station that initiates an input signal for any conventional control panel (FACP). Single or Dual Action Versions. UL, CSFM and FM Approvals.

NBG-12LR
(5811)

NOTIFIER  NBG-12LR

Notifier NBG-12LR Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual-action agent release station. FM Approved and cUL Listed.

4099-9004
(6848)

SIMPLEX TYCO  4099-9004

Simplex Tyco 4099-9004 addressable manual station with communication module for IDNet or MAPNET II. LED indicator. Breakglass or push operation. Surface or Flush mounting. NEMA 1. Complies with ADA requirements. UL listed.

NBG-12LX
(2042)

NOTIFIER  NBG-12LX

NOTIFIER by Honeywell NBG-12LX Addressable Manual Pull Station, dual-action (requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel.

NBG-12LOB
(4603)

NOTIFIER  NBG-12LOB

Notifier NBG-12LOB Pull Station which provides a Fire Alarm Control Panel (FACP) with a single alarm input signal. Includes dual action operation, Key-Lock Reset function, outdoor-use gasket and sealed switch. UL Listed.



 
NBG-12LRA
(4142)

NOTIFIER  NBG-12LRA

Notifier NBG-12LRA Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual action operation. Abort switch. Power-on and released indication. FM Approved and cUL Listed.

BG3W1NNN_BR
(1587)

MEDC  BG3W1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. Weatherproof. IP66 and IP67.

Configure

$190.05 
IS-CP4A-BG-ST-NF-NL-RD
(4080)

E2S  IS-CP4A-BG-ST-NF-NL-RD

E2S IS-CP4A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PB-ST-NL-RD
(4081)

E2S  IS-CP4A-PB-ST-NL-RD

E2S IS-CP4A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PT-ST-NL-RD
(4082)

E2S  IS-CP4A-PT-ST-NL-RD

E2S IS-CP4A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

BExCP3A-BG-ST-NF-NL-RD
(4083)

E2S  BExCP3A-BG-ST-NF-NL-RD

E2S BExCP3A-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3B-BG-ST-NF-NL-RD-06
(5136)

E2S  BExCP3B-BG-ST-NF-NL-RD-06

E2S BExCP3B-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BG2WNN1_NR
(1586)

MEDC  BG2WNN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. Weatherproof. IP66 and IP67.

Configure

$318.20 
BG3I1NNN_BR
(4152)

MEDC  BG3I1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. ATEX approved Ex II 1G. IP66 and IP67.

Configure

$322.60 
GNEXCP6A-BG-SNNNRD
(4086)

E2S  GNEXCP6A-BG-SNNNRD

E2S GNExCP6A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-BG-SNSNNRD06
(6443)

E2S  GNEXCP6B-BG-SNSNNRD06

E2S GNExCP6B-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

BG2EDC1_NR
(4150)

MEDC  BG2EDC1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. DC or AC Version. EExed IIC T6 (T4 if resistors or diode fitted) ATEX Approved Ex II 2G. IP66 and IP67.

Configure

$353.50 
BG2INN1_NR
(4151)

MEDC  BG2INN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. EExia IIC T4, ATEX Approved Ex II 1G. IP66 and IP67.

Configure

$371.17 
BExCP3A-PB-ST-NL-RD
(4084)

E2S  BExCP3A-PB-ST-NL-RD

E2S BExCP3A-PB Push Button Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.