Honeywell S3kul2-xnxxsa1ss | Ammonia | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   S3KUL2-XNXXSA1SS

HONEYWELL S3KUL2-XNXXSA1SS
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring AMMONIA (NH3) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-200ppm, 0-1000ppm. Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

S3KUL2-XNXXSA1SS   
1,837.05

Gas Range
Agency Approval/Enclosure
Splash Guard
Custom Tag

   4 Weeks  ]



Honeywell Series 3000 Display
FEATURES

Reliable detection
  • Proven electrochemical sensing technology
  • Uses Surecell™ electrochemical cells, ideal for hot and humid environments
  • Long life sensing elements (typical >2 years)
  • Patented 'Reflex' sensing elemen verification diagnostics
Reduced installation costs
  • Universal mounting bracket included, supplied as standard
  • Explosion proof transmitter allows field wiring to be run along with other non IS instruments
  • Plug-in sensor removes wiring
Reduced commissioning costs
  • Sensor recognition software auto configures transmitter
  • Non-intrusive configuration
  • Plug and play factory configured sensors
Reduced maintenance costs
  • IS sensor connection permits hot swap, reducing down time
  • User programmable calibration frequency
  • Integral fault diagnostic software
  • Menu/icon driven calibration procedure
  • IP 66 rated to protect against dust/water ingress
Regulatory compliance
  • US (UL)
  • Canadian (cUL/CSA)
  • International (IECEx)
  • European (ATEX)
Range of optional accessories
  • Remote sensor mounting kit
  • Duct mounting kit (for H2, CO and H2S only)
  • Calibration cup to apply test gas
  • Collecting cone (for H2 and CO only)
Typical applications
  • Exploration and drilling platforms
  • Production platforms
  • Onshore oil and gas terminals
  • Refineries and chemical plants
  • Power plants
  • Waste water facilities
  • Utilities
Honeywell Series 3000 components

The Series 3000 MkII provides comprehensive monitoring of toxic and oxygen gas hazards in potentially explosive atmospheres, both in and out of doors. This low powered gas detector operates on an industry standard 2-wire 4-20mA loop, making it ideal for both new and retrofit applications. Users can configure the detector without the need of a ‘hot work permit’ by using the LCD and magnetic switches. Fault diagnostic software and configurable calibration intervals simplify maintenance procedures.

The Intrinsically Safe smart sensors are supplied pre-configured and can be ‘hot swapped’ without having to remove power to the detector, saving time and money during commissioning and routine servicing. A remote sensor mounting kit is available that allows the sensor to be mounted up to 50’ (15m) from the transmitter, making it ideal for operation in areas that are difficult to access.

Series 3000 MkII is supplied with all necessary accessories for easy installation. The detector can be mounted on a wall or support pole using the universal bracket provided. Electrical installation can be made using either conduit or cable with suitable mechanical protection. A ¾” NPT entry and M20 adapter are included as standard. A weatherproof cap is also included for use in the harshest outdoor conditions.

Detectable Gas
Gas Formula Selectable Full Default Range Default Range Operating Temperature**
Min Max
Ammonia NH3 50 to 200ppm 200ppm -20°C / -4°F 50°C / 122°F
Series 3000 MkII Detector
Use Rugged and reliable gas detector for the protection of personnel from toxic and Oxygen gas hazards. Suitable for use in Zone 1 or 2 hazardous areas and North American Class I and II Division 1 or 2 areas.
Electrical
Connections and Power 2-wire loop powered
17VDC (+ / -10%) to 24VDC (max) operation
22mA max. over range
Signal 2-wire with screen (90% coverage) or conduit
0.5mm2 (20AWG) to 2.0mm2 (14AWG)
Connections and Power 0-100% FSD 4-20mA
Fault = 3mA
Calibration due selectable off or 3mA
Max. over range 22mA
Inhibit (toxic sensors) = Selectable 3mA or 4mA Inhibit
(Oxygen sensors) = Selectable 3mA or 17.4mA
Construction
Material Transmitter: Epoxy painted aluminium alloy LM25 or 316 Stainless Steel
Sensor: 316 Stainless Steel with PTFE filter
Maximum Dimensions 164mm x 201mm x 99mm
6.4" x 7.9" x 3.9"
Weight Aluminium alloy LM25: 1.7kg (3.75lbs.) Stainless Steel 316: 3.7kg (8.16lbs.)
Environmental
IP Rating IP66 (EN 60529), NEMA 4X
Certified Temperature ATEX/IECEX: -20°C to +55°C (-4°F to +131°F)
UL/c-UL: -40°C to +55°C (-40°F to +131°F)
Operating Humidity Continuous 20-90% RH (non-condensing)
Intermittent 0-99% RH (non-condensing)
Operating Pressure 90-110kPa
Storage Conditions 15°C to 30°C (59°F to 86°F) 30-70% RH (non-condensing)
Certification UL/c-UL Class I, Div 1 & 2, Groups B, C & D; Class II, Div 1, Groups E, F, G; Class II, Div 2, Groups F & G, Class I Zone 1, Group 2B + H2 Hazardous Locations
ATEX: II 2 (1) G Ex d [ia] IIB+H2 T4 (Tamb -20°C to +55°C / -4°F to 131°F)
IECEx Ex d [ia] IIB + H2 T4
Approvals CE compliant in accordance with:
ATEX Directive 94/9/EC
EMC Directive 2004/108/EC
EN 50270
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
S3KCAL
(715)

HONEYWELL  S3KCAL

Calibration cup (flow adaptor) for Honeywell Series 3000 transmitters. (for use with XNX EC sensors)



$117.16 
SCOTT-077-0207-EQUIV
(2430)

PORTAGAS  SCOTT-077-0207-EQUIV

Calibration Gas Ammonia 500ppm Balance Nitrogen Size 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas)

Configure

$252.43 
CYL-10005500
(1268)

PORTAGAS  CYL-10005500

Calibration Gas Ammonia (NH3) 100 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$252.43 
(261)

GDS  10-0263

GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent



 
S3KA1SS
(700)

HONEYWELL  S3KA1SS

Replacement Sensor Cartridge for Ammonia (NH3) S3000 transmitter 0-200ppm, user adjustable (50 to 200ppm, 50ppm increments)



$690.51 
S3KRMK
(716)

HONEYWELL  S3KRMK

Remote sensor mounting kit for Honeywell Series 3000 transmitters.

Configure

$700.84 
S3KA2SS
(699)

HONEYWELL  S3KA2SS

Replacement Sensor Cartridge for Ammonia (NH3) S3000 transmitter 0-1000ppm, user adjustable (200 to 1000ppm, 50ppm increments)



$722.65 
> AMMONIA :    42 Items found.
M001-0006-000
(5993)

MPOWER  M001-0006-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ammonia (NH3) 0-100ppm or 0-500ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$318.40 
BWS1-A_-Y
(6382)

BW  BWS1-A-Y

BW Solo Serviceable Single-gas Detector for Ammonia (NH3) 0-100 ppm or 0-1000ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$687.74 
TX-12-AM
(3418)

MACURCO  TX-12-AM

MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$690.96 
364-455-01-365-761-11050
(6149)

DELPHIAN  364-455-01-365-761-11050

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ammonia (NH3) 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-4824
(6803)

PROSENSE  PC3-4824

Prosense PC3-4824 Gas Detector with Electrochemical sensor for Ammonia (NH3) with range 0-100 ppm or 0-1000 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-4834
(6778)

PROSENSE  P-4834

Prosense P-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXA1
(1486)

HONEYWELL  SPSTAXA1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Ammonia (NH3) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-50 ppm, 0-1000 ppm)

Configure

$979.29 
PQN-4834-1/2
(6920)

PROSENSE  PQN-4834-1/2

Prosense PQN-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
LBW-WATCHMAN-SS
(4486)

COOL AIR  LBW-WATCHMAN-SS

Cool Air LBW-Watchman Ammonia (NH3) 0-1000ppm Leak Detector. 4-20mA analog output. NEMA 4X, UL Listed enclosure. IP66. 24VDC.

Configure

$1,086.50 
LBW-50-1-SS
(910)

COOL AIR  LBW-50-1-SS

Cool Air LBW-50 Ammonia (NH3) 0-1000ppm Gas Leak Detector. NEMA 4X IP66 enclosure. Alarm, pre-alarm and auxiliary relays. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC

Configure

$1,176.70 
2106B1413
(1458)

HONEYWELL  2106B1413

Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,217.33 
PQD-4834-1/2
(6739)

PROSENSE  PQD-4834-1/2

Prosense PQD-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109012/0300P-L0
(6908)

RC SYSTEMS  1100ALD-109012/0300P-L0

RC Systems SenSmart 1100 gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,314.28 
LBW-50-RLV
(914)

COOL AIR  LBW-50-RLV

Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 100 to 240VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed

Configure

$1,332.50 
GG-NH3-0100
(2966)

CALIBRATION TECHNOLOGIES  GG-NH3-0100

CTI GasGuard NH3 Ammonia Electrochemical Sensor (0-100, 0-250, 0-500 or 0-1000 ppm) for gas leak detection in food processing areas, cold storage, compressor rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,349.00 
GG-NH3-2
(2967)

CALIBRATION TECHNOLOGIES  GG-NH3-2

CTI GasGuard NH3-2% Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressor rooms, emergency shutdown, E-stop, heat treatment and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,394.00 
GG-VL2-NH3
(2970)

CALIBRATION TECHNOLOGIES  GG-VL2-NH3

CTI GasGuard NH3 Ammonia Vent Line 0-1% (0-10000 ppm) for gas leak detection in refrigeration system relief valves (outdoor installations only). 4-20 mA output, 24VDC power supply and NEMA 4X stainless enclosure.

Configure

$1,434.00 
100-0008-SS/100-0015-NH3
(4759)

ESP SAFETY  100-0008-SS/100-0015-NH3

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Ammonia (NH3) 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
41001AL-0-1015/0300P/L0
(7158)

RC SYSTEMS  41001AL-0-1015/0300P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,538.96 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.