Medc Ph1ul11m3msnnnr | Call Points | Class I Div 1 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MEDC   PH1UL11M3MSNNNR

MEDC PH1UL11M3MSNNNR

ALARM SIGNAL DEVICES / CLASS I DIV 1
CALL POINTS

$1,879.54  [9 Weeks]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. UL Class 1, Division 1 Gas groups B, C & D or UL Class 1, Division 2. Gas groups A - D.

PH1UL11M3MSNNNR   
1,879.54

Certification
Entries
Entries
Switches
Options
Options
Options
Finish

   9 Weeks  ]
251 Variants of base SKU / 30 Shown below

The PH1 double action pull handle call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where light weight combined with a high level of corrosion resistance is required.

The large "Lift" and "Pull" GRP handles can be operated effortlessly whilst wearing industrial gloves and require double action to raise the alarm, preventing accidental activation.

FEATURES

  • Zone 1 and Zone 2 use.
  • UL Listed for:
    • Hazardous Locations.
    • Class I, Division 1. Groups B, C & D.
    • Class I, Division2. Groups A-D.
    • Zone 1.
    • Ordinary Locations: Fire alarm boxes.
  • Ex d IIC T6 Gb.
  • Ex tb IIIC T85oC Db.
  • IECEx certified Gb, Db.
  • ATEX certified Ex II 2 GD.
  • NEMA 4X & 6. IP66 & IP67.
  • Certified temperature: -55oC to +70oC*.
  • Corrosion free GRP construction.*
  • Optional in line, end of line resistors and diodes.
  • Retained stainless steel cover screws.

Certification and Specification
UL Haz Locs: UL listed for USA and Canada.
Listing no. E186629.
Class I, Div. 1. Groups B, C & D.
Class I, Div. 2. Groups A- D.
Class I, Zone 1, AEx d IIC, Ex d IIC.
Class II, Div.2, Groups F & G.
Class III.
UL Ord Locs: UL Listing no. S8117. Fire alarm boxes.
UL for USA and Canada.
IECEx Ex d: Cert. no. IECEx ITS.11.0021X.
Certified to: IEC60079-0, IEC60079-1, IEC60079-31.
Ex d IIC T6 Gb, Ex tb IIIC T85oC Db. IP66.
ATEX Ex d: Cert. no. ITS11ATEX17308X.
Certified to: EN60079-0, EN60079-1, EN60079-31.
Ex II 2 GD, Ex d IIC T6 Gb, Ex tb IIIC T85oC Db. IP66.
Material: Body/covers/handles:- GRP (glass reinforced polyester).
UL Class I, Div. 1 Inner Cover: 316 (ANC4B) Stainless Steel.
Fixings:- Stainless steel grade 316.
Finish: Cover:- natural red, Body:- natural black.
Handles:- natural white.
Cover may be painted to customer's requirements.
Voltage: 0-50Vdc, 0-254Vac.
Switch Rating: 1 or 2 c/o switches, 254V, 3A max.
Weight: UL Class I, Div 2, ATEX, IECEx & UW: Gross weight 3.2Kg.
Net weight 2.6Kg.
UL Class I, Div. 1: Gross weight 4.4 Kg. Net weight 3.8Kg.
Certified Temp: ATEX & IECEx: -55oC to +70oC. UL Class I, Divs. 1 & 2, UW: -50oC to +70oC
Ingress Protection: NEMA 4X & 6. IP66 & IP67.
Entries: UL Class I, Div. 1 - Max 1 per face. Up to 2 x 1 / 2 ” NPT or 3 / 4 ” NPT.
Positions 2 & 5 only.
UL Class I, Div. 2, UW: Up to 2 x 1 / 2 ” or 3 / 4 ” NPT. 3 / 4 ” NPT,
Max. 1 per face & positions 2 & 5 only.
ATEX, IECEx - Max 2 per face. Up to 2 x M20 or M25, up to 2 x 1 / 2 ” or 3 / 4 ” NPT.
Please note that certified blanking plugs cannot be fitted to this product.
Terminals: 6 x 2.5mm2 as standard. Contact MEDC for options
Earth Continuity: Earth continuity is provided by internal plate.
Duty Labels: Burning house' label fitted as standard on red units.
Red blank duty label fitted as standard on all other colour units, unless text is supplied by customer.
Tag Label: worded to customers requirements.
Addr. module: Consult MEDC for options.
Resistors: Various configurations available, 470 Ohms minimum.
Diodes: Various configurations available.
Export Info
Made inUnited Kingdom

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
NBG-12
(6824)

NOTIFIER  NBG-12

NOTIFIER by Honeywell NBG-12 Non-Coded Conventional Manual Fire Alarm Pull Station that initiates an input signal for any conventional control panel (FACP). Single or Dual Action Versions. UL, CSFM and FM Approvals.

NBG-12LR
(5811)

NOTIFIER  NBG-12LR

Notifier NBG-12LR Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual-action agent release station. FM Approved and cUL Listed.

4099-9004
(6848)

TYCO  4099-9004

Tyco Simplex 4099-9004 addressable manual station with communication module for IDNet or MAPNET II. LED indicator. Breakglass or push operation. Surface or Flush mounting. NEMA 1. Complies with ADA requirements. UL listed.

Configure

$67.52 
NBG-12LX
(2042)

NOTIFIER  NBG-12LX

NOTIFIER by Honeywell NBG-12LX Addressable Manual Pull Station, dual-action (requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel.

NBG-12LOB
(4603)

NOTIFIER  NBG-12LOB

Notifier NBG-12LOB Pull Station which provides a Fire Alarm Control Panel (FACP) with a single alarm input signal. Includes dual action operation, Key-Lock Reset function, outdoor-use gasket and sealed switch. UL Listed.



 
NBG-12LRA
(4142)

NOTIFIER  NBG-12LRA

Notifier NBG-12LRA Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual action operation. Abort switch. Power-on and released indication. FM Approved and cUL Listed.

BG3W1NNN_BR
(1587)

MEDC  BG3W1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. Weatherproof. IP66 and IP67.

Configure

$193.80 
IS-CP4A-BG-ST-NF-NL-RD
(4080)

E2S  IS-CP4A-BG-ST-NF-NL-RD

E2S IS-CP4A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PT-ST-NL-RD
(4082)

E2S  IS-CP4A-PT-ST-NL-RD

E2S IS-CP4A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PB-ST-NL-RD
(4081)

E2S  IS-CP4A-PB-ST-NL-RD

E2S IS-CP4A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

BExCP3B-BG-ST-NF-NL-RD-06
(5136)

E2S  BExCP3B-BG-ST-NF-NL-RD-06

E2S BExCP3B-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3A-BG-ST-NF-NL-RD
(4083)

E2S  BExCP3A-BG-ST-NF-NL-RD

E2S BExCP3A-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BG2WNN1_NR
(1586)

MEDC  BG2WNN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. Weatherproof. IP66 and IP67.

Configure

$324.48 
BG3I1NNN_BR
(4152)

MEDC  BG3I1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. ATEX approved Ex II 1G. IP66 and IP67.

Configure

$328.96 
GNEXCP6A-BG-SNNNRD
(4086)

E2S  GNEXCP6A-BG-SNNNRD

E2S GNExCP6A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-BG-SNSNNRD06
(6443)

E2S  GNEXCP6B-BG-SNSNNRD06

E2S GNExCP6B-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

BG2EDC1_NR
(4150)

MEDC  BG2EDC1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. DC or AC Version. EExed IIC T6 (T4 if resistors or diode fitted) ATEX Approved Ex II 2G. IP66 and IP67.

Configure

$360.46 
BG2INN1_NR
(4151)

MEDC  BG2INN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. EExia IIC T4, ATEX Approved Ex II 1G. IP66 and IP67.

Configure

$378.49 
BExCP3A-PT-ST-NL-RD
(4085)

E2S  BExCP3A-PT-ST-NL-RD

E2S BExCP3A-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3A-PB-ST-NL-RD
(4084)

E2S  BExCP3A-PB-ST-NL-RD

E2S BExCP3A-PB Push Button Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.