VOC:    43 Items found.
(220)

GDS  GMII-01-011-06/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Carbon Monoxide (CO) with range 0-300/0-1000 ppm (included).



 
(223)

GDS  GMII-01-014-19/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen (H2) with range 0-2000 ppm (included).



 
(224)

GDS  GMII-01-015-04/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen Sulfide (H2S) with range 0-50/0-100 ppm (included).



 
(225)

GDS  GMII-01-016-12/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-50 ppm (included).



 
(228)

GDS  GMII-01-019-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Sulfur Dioxide (SO2) with range 0-20/0-100 ppm (included).



 
(231)

GDS  GMII-01-022-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Ethylene Oxide ETO (C2H4O) with range 0-20 ppm (included).



 
(221)

GDS  GMII-03-012-02/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with local aluminun sensor head configured for Chlorine (Cl2) with range 0-5/0-50 ppm (included).



 
(222)

GDS  GMII-03-013-01/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (ClO2) with range 0-1 ppm (included).



 
(226)

GDS  GMII-03-017-12/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Hydrogen Chloride (HCL) with range 0-30 ppm (included).



 
(227)

GDS  GMII-03-018-02/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Hydrogen Fluoride (HF) with range 0-10 ppm (included).



 
(229)

GDS  GMII-03-020-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Ammonia (NH3) with range 0-100 ppm (included).



 
(230)

GDS  GMII-03-021-01/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Ozone (O3) with range 0-1 ppm (included).



 
(4307)

HONEYWELL  H-D03-0009-000

Honeywell RAEGuard 2 PID Photoionization Detector for VOCs (Volatile Organic Compounds), 10.6 eV Lamp only. 10 to 28 VDC. 4-20mA three-wire and RS-485 Modbus outputs. Explosion-proof stainless-steel enclosure. Graphic display. LED light status indicator. IP65. UL approved for Class I Div 1. (Zone 1). ATEX and IECEx also available.

Configure

$7,365.27 
(6339)

BW  HU-0000000000-Y-N

Honeywell BW Ultra Portable Multi-Gas Detector for up to 5 gases. Detects Oxygen (O2) 0-25% vol, Combustibles 0-100% LEL (Lower Explosive Limit), Hydrogen Sulfide (H2S) 0-100ppm, Carbon Monoxide (CO) 0-2000ppm, Ammonia (NH3) 0-100ppm, Carbon Dioxide (CO2) 0-50000ppm, Sulfur Dioxide (SO2) 0-100ppm and Volatile Organic Compounds (VOCs) 0-1000ppm. Visual, vibrating and audible (95 dB) alarms. Includes battery, BLE and event logger. IP66/68. cULus, ATEX, IECEx and CE approvals.

(6337)

MPOWER  M011-0004-000

mPower NEO Photo-ionization Handheld Gas Detector for Volatile Organic Compounds (VOC). Ranges from 1 ppb up to 15,000 ppm. Audible (90dB0), Visual (flashing LEDs) and wireless remote alarms. Built-in wireless modem and pump. Includes Bluetooth Low Energy (BLE) connectivity, Lithium-ion battery and USB Micro charger. Backlight display. Stainless steel housing. IP66/IP67. UL approval for Class I Div 1.

Configure

$2,560.00 
(6336)

MPOWER  MPA1-210000-00000

mPower POLI MP400P 5-gas multi-gas detector for toxic gases, optional Oxygen (O2) 0-30% Vol, combustibles (LEL) 0-100%, Carbon Dioxide (CO2) 0-50000ppm, CO2, SO2, combustibles IR, NO, NO2, Cl2, ClO2, HCl, HCN, NH3, PH3, HF, H2, EtO, CH3SH, THT, COCl2, AsH3 and volatile organic compounds (VOCs) 0-2000ppm on hazardous locations. Diffusion or Built-in pump. Audible (90dB0), Visual (flashing LEDs), Vibration and Man-Down alarms. Includes rechargeable Li-ion battery and event logger. IP67. ATEX and UL approved for Class I, Div 1.

Configure

$480.00 
(6470)

INDUSTRIAL SCIENTIFIC  MX6-00000301

Industrial Scientific MX6 iBrid Multi Gas Detector for up to 6 gases. Detects Oxygen (O2), toxic gases, combustible gases (LEL) and volatile organic compounds (VOCs). Catalitic Bead, Electrochemical, Infrared or PID sensors. Includes Full-color LCD Display and 95dB audible alarm. Concussion-proof overmold. IP64. ATEX, CSA, IECEx, UL & INMETRO Approvals.

(6720)

PROSENSE  PQD-8136-1/2

Prosense PQD-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$2,851.20 
(6965)

PROSENSE  PQN-8136-1/2

Prosense PQN-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$2,661.12 
(341)

GDS  S6XR-S

Photoionization Detector Sensor Refurbishment (includes lamp replacement if necessary)



 