Gasdetectorsusa.com:gas Leak And Flame Detectors, Analyzers, Alarm Devices And Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
VOC:    43 Items found.
(7104)

RC SYSTEMS  10-9030

RC Systems 10-9030/10-9027/10-9028/10-9029/10-9561/10-9562/10-9564/10-9564 Photoionization Detector (PID) Sensor Assembly for Series 1000, 3000, 5000, 6000 Gas Detectors with ST-44 & ST-48 transmitter, Volatile Organic Compounds (VOC) 10.0eV or 10.6eV, 0-40ppm to 0-1000ppm

Configure

$2,453.24 
(339)

GDS  10-9561-R05

PID Photoionization Sensor configured for VOC (10.6eV, 0-50 ppm Isobutylene). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
(340)

GDS  10-9562-R19

PID Photoionazation Sensor configured for VOC (10.6eV, 0-200 ppm Isobutylene). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
(3410)

GDS  10-9564-R05

PID Photoionization Sensor configured for VOC (10.0eV, 0-50 ppm Isobutylene). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
(3411)

GDS  10-9565-R19

PID Photoionazation Sensor configured for VOC (10.0eV, 0-300 ppm Isobutylene/or Other detectable VOC -Specify-). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
(3375)

GDS  10-9861-R05

PID Photoionization Sensor configured for VOC (10.6eV, 0-50 ppm Isobutylene). For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
(3376)

GDS  10-9862-R19

PID Photoionazation Sensor configured for VOC (10.6eV, 0-300 ppm Isobutylene). For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
(3377)

GDS  10-9864-R05

PID Photoionization Sensor configured for VOC (10.0eV, 0-50 ppm Isobutylene). For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
(3378)

GDS  10-9865-R19

PID Photoionazation Sensor configured for VOC (10.0eV, 0-300 ppm Isobutylene). For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
(6896)

RC SYSTEMS  35001AL-0-9029/0010P/L0

RC Systems SenSmart 3500 3 wire gas detector for Volatile Organic Compounds VOC 0-40ppm to 0-1000ppm Isobutylene with 'ST-48' smart transmitter with 10.0eV or 10.6eV PID sensor with arctic heater. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$3,662.33 
(7120)

RC SYSTEMS  55001AL-0-9027/100P/L0

RC Systems SenSmart 5500 3-wire gas detector for Volatile Organic Compounds VOC 10.0eV or 10.6eV with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$3,289.61 
(6066)

DETCON  967-PB5520-010

Detcon PI-700 Universal Smart Gas Sensor with Photo Ionization Detector (PID) technology for VOC 0-10ppm to 0-5000ppm. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Built-in numeric display. Water-Proof, Corrosion-Proof and Vibration-Proof. NEMA4X. IP66. CSA (Class I Div 1) and ATEX Approvals.

(6472)

DEFIANT TECHNOLOGIES  DT-FG5K1-S52

Defiant Technologies FROG-5000 Gas Chromatography Hand Held System for Volatile Organic Compounds (VOC) Analysis in Water, Air and Soil. Portable GC PID Detector. RS-232 port and LCD display. 9 Hour Battery Life. Includes air sampler, software, 12 Activated Carbon replacements, 12 Mol Sieves replacements and tool kit.



 
(4469)

FELIX  F-750

Felix F-750 Portable Produce Quality Spectrometer for analysis of internal and external traits. Measures dry matter, brix, assess fruit maturity and skin color. Near Infrared Analysis (NIR). Battery Powered. Reports quantitative estimates of many substances like Chlorophyll. Includes GPS, LCD transflective display, rechargeable batteries, Data transfer via WiFi/USB/SD card, Xenon Tungsten Lamp.

Configure

$9,357.50 
(6207)

FELIX  F-751AVO

Felix F-751 Portable Avocado Quality Meter with Near Infrared Analysis (NIR). Measures dry matter in avocado and ripeness. Non-destructively. Includes GPS, LCD transflective display, data transfer via WiFi/USB/SD card, rechargeable batteries.



$4,835.50 
(5955)

ION SCIENCE  FAXSXBXX-3000D

Ion Science Falco Fixed Detector for Volatile Organic Compounds (VOCs) in condensing atmospheres and extreme weather. PID sensor with 10.6 eV lamp. Pumped or diffused versions available. Includes Multi-coloured status display and long-life lamp. ATEX, IECEx, UL and CSA approvals.

Configure

$3,822.00 
(347)

GDS  GDS-48-1-61-06

GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with Photoionization Detector (PID) for VOC (Volatile Organic Compounds). 3-Wire Bridge Output. CSA Certified for Div. 1 Explosion Proof.



 
(3311)

GDS  GMCX-01-61-05/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with a photoionization detector (PID) to detect VOC (Volatile Organic Compounds) with range 0-50/0-300 ppm Isobutylene Equivalent, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.



 
(609)

GDS  GMII-00-000-00/01-061-05/0-0

GDS GASMAX II PID 3-Wire Gas Detector with a photoionization detector (PID) to detect VOC (Volatile Organic Compounds) with range 0-50/0-300 ppm Isobutylene Equivalent, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1.



 
(219)

GDS  GMII-01-010-04/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Oxygen with range 0-25% (included).



 
(220)

GDS  GMII-01-011-06/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Carbon Monoxide (CO) with range 0-300/0-1000 ppm (included).



 
(223)

GDS  GMII-01-014-19/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen (H2) with range 0-2000 ppm (included).



 
(224)

GDS  GMII-01-015-04/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen Sulfide (H2S) with range 0-50/0-100 ppm (included).



 
(225)

GDS  GMII-01-016-12/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-50 ppm (included).



 
(228)

GDS  GMII-01-019-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Sulfur Dioxide (SO2) with range 0-20/0-100 ppm (included).



 
(231)

GDS  GMII-01-022-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Ethylene Oxide ETO (C2H4O) with range 0-20 ppm (included).



 
(221)

GDS  GMII-03-012-02/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with local aluminun sensor head configured for Chlorine (Cl2) with range 0-5/0-50 ppm (included).



 
(222)

GDS  GMII-03-013-01/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (ClO2) with range 0-1 ppm (included).



 
(226)

GDS  GMII-03-017-12/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Hydrogen Chloride (HCL) with range 0-30 ppm (included).



 
(227)

GDS  GMII-03-018-02/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Hydrogen Fluoride (HF) with range 0-10 ppm (included).



 
(229)

GDS  GMII-03-020-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Ammonia (NH3) with range 0-100 ppm (included).



 
(230)

GDS  GMII-03-021-01/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Ozone (O3) with range 0-1 ppm (included).



 
(4307)

HONEYWELL  H-D03-0009-000

Honeywell RAEGuard 2 PID Photoionization Detector for VOCs (Volatile Organic Compounds), 10.6 eV Lamp only. 10 to 28 VDC. 4-20mA three-wire and RS-485 Modbus outputs. Explosion-proof stainless-steel enclosure. Graphic display. LED light status indicator. IP65. UL approved for Class I Div 1. (Zone 1). ATEX and IECEx also available.

Configure

$7,365.27 
(6339)

BW  HU-0000000000-Y-N

Honeywell BW Ultra Portable Multi-Gas Detector for up to 5 gases. Detects Oxygen (O2) 0-25% vol, Combustibles 0-100% LEL (Lower Explosive Limit), Hydrogen Sulfide (H2S) 0-100ppm, Carbon Monoxide (CO) 0-2000ppm, Ammonia (NH3) 0-100ppm, Carbon Dioxide (CO2) 0-50000ppm, Sulfur Dioxide (SO2) 0-100ppm and Volatile Organic Compounds (VOCs) 0-1000ppm. Visual, vibrating and audible (95 dB) alarms. Includes battery, BLE and event logger. IP66/68. cULus, ATEX, IECEx and CE approvals.

(6337)

MPOWER  M011-0004-000

mPower NEO Photo-ionization Handheld Gas Detector for Volatile Organic Compounds (VOC). Ranges from 1 ppb up to 15,000 ppm. Audible (90dB0), Visual (flashing LEDs) and wireless remote alarms. Built-in wireless modem and pump. Includes Bluetooth Low Energy (BLE) connectivity, Lithium-ion battery and USB Micro charger. Backlight display. Stainless steel housing. IP66/IP67. UL approval for Class I Div 1.

Configure

$2,560.00 
(6336)

MPOWER  MPA1-210000-00000

mPower POLI MP400P 5-gas multi-gas detector for toxic gases, optional Oxygen (O2) 0-30% Vol, combustibles (LEL) 0-100%, Carbon Dioxide (CO2) 0-50000ppm, CO2, SO2, combustibles IR, NO, NO2, Cl2, ClO2, HCl, HCN, NH3, PH3, HF, H2, EtO, CH3SH, THT, COCl2, AsH3 and volatile organic compounds (VOCs) 0-2000ppm on hazardous locations. Diffusion or Built-in pump. Audible (90dB0), Visual (flashing LEDs), Vibration and Man-Down alarms. Includes rechargeable Li-ion battery and event logger. IP67. ATEX and UL approved for Class I, Div 1.

Configure

$480.00 
(6470)

INDUSTRIAL SCIENTIFIC  MX6-00000301

Industrial Scientific MX6 iBrid Multi Gas Detector for up to 6 gases. Detects Oxygen (O2), toxic gases, combustible gases (LEL) and volatile organic compounds (VOCs). Catalitic Bead, Electrochemical, Infrared or PID sensors. Includes Full-color LCD Display and 95dB audible alarm. Concussion-proof overmold. IP64. ATEX, CSA, IECEx, UL & INMETRO Approvals.

(6720)

PROSENSE  PQD-8136-1/2

Prosense PQD-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$2,851.20 
(6965)

PROSENSE  PQN-8136-1/2

Prosense PQN-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$2,661.12 
(341)

GDS  S6XR-S

Photoionization Detector Sensor Refurbishment (includes lamp replacement if necessary)



 
(6605)

DETCON  S927-P1000-100

Detcon PI-700-VOC Volatile Organic Compound ITM (Intelligent Transmitter Module) Spare Part.

(5956)

ION SCIENCE  TXLLSLBMR-0000

Ion Science Tiger XTL handheld detector for Volatile Organic Compounds (VOCs) with PID sensor (0-5000ppm). 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger LT ***

Configure

$3,724.00 
(5163)

ION SCIENCE  TXXXSLBMP-0005

Ion Science Tiger XT Select PID (photoionization) handheld detector for Volatile Organic Compounds (VOCs) with dynamic range 1ppb to 20000ppm and internal gas table with over 750 compounds. 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger ***

Configure

$6,188.70 


Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.