Macurco Nd-2 | Nitrogen Dioxide | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MACURCO   ND-2

MACURCO ND-2
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Macurco ND-2 nitrogen dioxide gas detector and transducer features a digital display (0-9ppm), NEMA 1 enclosure, 12-24 VAC or VDC operation, adjustable relay and 4-20mA output. For use with the Macurco DVP-120 control panel and HVAC/Building Automation Systems. ***** DISCONTINUED **** Replaced by TX-6-ND

Inquiry

REPLACED BY TX-6-ND

FEATURES
  • Automatic Ventilation Controller
  • 4 to 20 mA Output, for 0 to 6 ppm
  • Microcomputer Controlled
  • Digital Display: 0 to 9 PPM NO2
  • Highly Linear Electrochemical Sensor
  • Relay w/Selectable Set Points & Delay
  • Diesel Exhaust Detection and Control
  • Specific to Nitrogen Dioxide.
  • Provides Nitrogen Dioxide detection, digital display of gas concentration, 4 to 20 mA output, and a relay to automatically control exhaust fans or other devices
  • ND-2 works on a wide range of power: 12 to 24 VAC or VDC
  • Meets the requirements of OSHA and the state of Wisconsin.
  • Housed in Nema 1, UL listed, metal knockout case.
  • Internally adjustable switch for relay delay from 0.5 to 5 minutes
  • Bright LED's show relay status: flashes during delay period, is on steady when the relay closes.
  • Reyearsplacement sensors and field calibration kit available. Normal sensor life is over 2 years.
  • Isolated 4 to 20 mA output (1000 volts) so common power supplies can be used
Parking Garage Warehouse Maintenance Facility
Ice Skating Arena Storage Facility

ND2 Specifications
Power 1.2 Watts from 12 to 24 VAC or VDC
Size 6 X 6 X 3 inches
Color Gray
Shipping Weight 3 pounds
Relay 5 amps, 240VAC, pilot duty, SPDT
Relay Set Point 0.5 to 3.0 PPM
Operating Environment 0 to 125° F, 10 to 90% RH
Linearity Within 1%
Accuracy (after calibration) +/- 3%
Sensor Output Droop Less than 2% a month.
All Units are Factory Calibrated
Typical Coverage 5000 square feet per unit
> ACCESSORIES - RELATED - CONSUMABLES :    2 Items found.
DMK-1
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
Cal-Kit 2*NO2-5PPM-AL
(646)

MACURCO  Cal-Kit 2*NO2-5PPM-AL

Macurco Cal-Kit 2 Nitrogen Dioxide (NO2) 5 ppm gas field calibration kit to calibrate Macurco gas detectors. 34L. Includes Carry Case, Regulator, Tubing and calibration hood 2ft. 1/cs. 30-0021-1110-1 & 70-0714-0531-3



$879.27 
> NITROGEN DIOXIDE :    29 Items found.
M001-0011-000
(6004)

MPOWER  M001-0011-000

mPower UNI MP100 Portable Single Gas Detector for detection of Nitrogen Dioxide (NO2) 0-20ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$278.40 
TX1-4
(5967)

INDUSTRIAL SCIENTIFIC  TX1-4

Industrial Scientific Tango TX1 Gas Detector for Nitrogen Dioxide (NO2) 1-150 ppm. DualSenseŽ Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

PPS+-NO2
(6814)

PROSENSE  PPS+-NO2

Prosense PPS+-NO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.



$429.00 
PPS-RNO2
(6812)

PROSENSE  PPS-RNO2

Prosense PPS-RNO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



$429.00 
BWS1-D-Y
(6391)

BW  BWS1-D-Y

BW Solo Serviceable Single-gas Detector for Nitrogen dioxide (NO2) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-ND
(2046)

MACURCO  TX-6-ND

Macurco TX-6-ND low voltage Gas Detector, Controller and Transducer for Nitrogen Dioxide (NO2) 0-20 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. power ETL Listed to UL 61010-1.

Configure

$648.99 
TX-12-ND
(3417)

MACURCO  TX-12-ND

MACURCO TX-12-ND line voltage Gas Detector, controller and transducer for Nitrogen Dioxide (NO2) 0-20ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$656.26 
364-455-01-365-732-01
(6156)

DELPHIAN  364-455-01-365-732-01

Delphian GazTell Fixed Point Electrochemical Gas Detector for Nitrogen Dioxide (NO2) 0-100ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-6824
(6809)

PROSENSE  PC3-6824

Prosense PC3-6824 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-6834
(6784)

PROSENSE  P-6834

Prosense P-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXN1
(1924)

HONEYWELL  SPSTAXN1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Nitrogen dioxide (NO2) 0-10ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved.

Configure

$993.35 
PQN-6834-1/2
(6957)

PROSENSE  PQN-6834-1/2

Prosense PQN-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
GG-NO2-B-10
(5982)

CALIBRATION TECHNOLOGIES  GG-NO2-B-10

CTI GG-NO2-B Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. NEMA 3RX polycarbonate housing. CSA and UL approved.

Configure

$1,088.34 
2106B1422
(1467)

HONEYWELL  2106B1422

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitrogen Dioxide (NO2) 0-10 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
PQD-6834-1/2
(6745)

PROSENSE  PQD-6834-1/2

Prosense PQD-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109024/007P-L0
(6915)

RC SYSTEMS  1100ALD-109024/007P-L0

RC Systems SenSmart 1100 gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,314.28 
GG-NO2-10-EXP
(5980)

CALIBRATION TECHNOLOGIES  GG-NO2-10-EXP

CTI GG-NO2-EXP Explosion Proof Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,341.51 
41001AL-0-1024/0005P/L0
(7175)

RC SYSTEMS  41001AL-0-1024/0005P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1024/0005P/L0
(7130)

RC SYSTEMS  51001AL-0-1024/0005P/L0

RC Systems SenSmart 5100 3-wire gas detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with GEN2 smart Electrochemical sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-640026-010G
(6371)

DETCON  961-640026-010G

Detcon DM-100-NO2 Electrochemical Nitrogen Dioxide (NO2) 0-10ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

SPXCDULNN2
(5107)

HONEYWELL  SPXCDULNN2

Honeywell Sensepoint XCD RTD Gas Detector for Nitrogen dioxide (NO2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 10 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
SPXCDULNNX
(666)

HONEYWELL  SPXCDULNNX

Honeywell XCD Sensepoint Gas Detector, Nitrogen Dioxide (NO2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for nitrogen dioxide (NO2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 10.0 to 50.0ppm. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,763.64 
2100AL-0-9024/007P/L0
(237)

RC SYSTEMS  2100AL-0-9024/007P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,789.61 
S3KUL2-XNXXSN1SS
(696)

HONEYWELL  S3KUL2-XNXXSN1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring NITROGEN DIOXIDE (NO2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-10.0ppm, user adjustable (5.0 to 50.0ppm, 5.0ppm increments) Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,789.84 
31001AL-0-9024/007P/L0
(5786)

RC SYSTEMS  31001AL-0-9024/007P/L0

RC Systems SenSmart 3100 3 wire gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,967.53 
967-646490-010
(6096)

DETCON  967-646490-010

Detcon DM-700-NO2 Electrochemical Smart Nitrogen Dioxide (NO2) 0-10 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSN1SS
(847)

HONEYWELL  XNXUTAENNNNN-XNXXSN1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Nitrogen Dioxide (NO2) 0-10.0ppm, user adjustable (5.0 to 50.0ppm, 5.0ppm increments) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,275.97 
6100AL1-0-1024/0005P
(7012)

RC SYSTEMS  6100AL1-0-1024/0005P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with 'ST-44' smart transmitter and GEN2 smart Electrochemical sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class 1 Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
I-900G-NO2-0010
(7112)

INTERSCAN  I-900G-NO2-0010

Interscan GASD 8000 Portable Trace Gas Detector with smart sensor for continuous air sampling of Nitrogen Dioxide (NO2). Anodized aluminum enclosure. Includes rechargeable batteries.

Configure

$6,750.00 
Cookie Notice