Rc Systems 2100al-0-9020/30p/l0 | Hydrogen Cyanide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

RC SYSTEMS   2100AL-0-9020/30P/L0

RC SYSTEMS 2100AL-0-9020/30P/L0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

2100AL-0-9020/30P/L0   
1,789.61

Enclosure Type
Splash Guard

 3 Weeks  ]



The SenSmart 2000 2-Wire 4-20mA Loop Powered Gas Monitor accepts oxygen and many toxic gases by offering a wide variety of electrochemical gas sensors. SenSmart 2000s utilize our popular “GEN 1 smart sensor” proprietary technology to provide sensor recognition and temperature compensation within the SenSmart 2000. Each GEN 1 smart sensor has its’ own non-volatile memory to store records of serial number, born-on date, initial calibration values, engineering units and temperature compensation algorithm.

FEATURES HIGHLIGHT
  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Graphic display shows values,units, trend graph, alarm levels
  • Non-polarized loop powered interface eliminates wiring errors
  • Three flashing Alarm LEDs with Programmable Alarm Levels
  • Real time clock tags alarm and calibration events
  • Non-intrusive, prompted calibration with programmable cal-gas
  • Power-up and post-calibration delays eliminate false alarms
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data and more
  • Fault supervision circuitry detects failed sensor and transmits warning
  • Setup in hazardous area requires only simple magnetic wand

OEM VERSION OF THE GDS CORP GASMAX EC

SPECIFICATIONS
Power Supply10-30VDC at less than 0.75 watts
Display64 x 128 pixel LCD with 30-minute trend, bar graph and engineering units display
Standard OutputStandard 2-wire 4-20mA current sink . Max loop Resistance is 600 ohms with nominal 24VDC power supply
TempElectronics -40°C to +60°C. See Electrochemical Sensor Manual for additional information
HousingAluminum with epoxy paint standard; Optional #316 stainless steel, Optional Ul94 Poly Black Plastic Enclosure
Dimensions(Aluminum) Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
(Poly) Width 5” (127 mm), Height 7” (178 mm), Depth 4” (101 mm) Shipping weight 3 pounds (2 kg)
ApprovalsCSA Certified Div 1 & 2 Groups B, C, D. Suitable for explosion-proof installations
CSA Certified Div 1 & 2 Groups A, B, C, D for Intrinsically safe installations
Warranty5 year limited warranty
For sensor warranty see sensor specifications sheet.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    8 Items found.
10-0203
(7043)

RC SYSTEMS  10-0203

RC SYSTEMS Sensor calibration cup adaptor for stainless steel / aluminum sensor heads



$95.71 
CYL-90094700
(610)

PORTAGAS  CYL-90094700

Calibration Gas Hydrogen Cyanide HCN 10 ppm Balance Nitrogen, 34 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$178.53 
10-0552
(7028)

RC SYSTEMS  10-0552

Sample Draw Flow Cell Barrel Adapter for RC Systems Gen I and Gen II 10-0247 Sensor heads(Series 1000, 2000, 3000, 5000 and 6000) gas detectors) 1/8" NPT ports (1 inlet 1 outlet). Used with ST-44 and ST-48 Transmitters.



$213.06 
CYL-10320254
(1310)

PORTAGAS  CYL-10320254

Calibration Gas Hydrogen Cyanide (HCN) 10 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$252.43 
10-9020
(7098)

RC SYSTEMS  10-9020

RC Systems 10-9020/10-9516 Gen I EC Smart Sensor for Series 1000, 2000, 3000 Gas Detectors with ST-48 transmitter, Hydrogen Cyanide (HCN) 0-30ppm.



$536.36 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20mA input channels board.

Configure

$2,820.78 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. UL and CSA approved for Class I, Division 2, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included. Standard SPDT 5A relays for HORN and FAULT, plus 3 programmable alarm relays included. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. Optional 4-20mA inputs.

Configure

$12,179.52 
> HYDROGEN CYANIDE :    15 Items found.
M001-0005-000
(5999)

MPOWER  M001-0005-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Cyanide (HCN) 0-100ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$358.40 
BWS1-Z-Y
(6388)

BW  BWS1-Z-Y

BW Solo Serviceable Single-gas Detector for Hydrogen cyanide (HCN) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

364-455-01-365-790-11
(6153)

DELPHIAN  364-455-01-365-790-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

P-7534
(6789)

PROSENSE  P-7534

Prosense P-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
1100ALD-109020/30P-L0
(6912)

RC SYSTEMS  1100ALD-109020/30P-L0

RC Systems SenSmart 1100 gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
PQN-7534-1/2
(6962)

PROSENSE  PQN-7534-1/2

Prosense PQN-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,338.48 
PQD-7534-1/2
(6750)

PROSENSE  PQD-7534-1/2

Prosense PQD-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,492.92 
41001AL-0-1020/0030P/L0
(7165)

RC SYSTEMS  41001AL-0-1020/0030P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen Cyanide (HCN) 0-30ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1020/30P/L0
(7128)

RC SYSTEMS  51001AL-0-1020/30P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen Cyanide (HCN) 0-30ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-130026-030G
(6366)

DETCON  961-130026-030G

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

S3KUL2-XNXXSY1SS
(6346)

HONEYWELL  S3KUL2-XNXXSY1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CYANIDE (HCN) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-30ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,899.32 
31001AL-0-9020/30P/L0
(5783)

RC SYSTEMS  31001AL-0-9020/30P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
967-131390-030
(6091)

DETCON  967-131390-030

Detcon DM-700-HCN Electrochemical Smart Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

6100AL1-0-1020/0030P
(7007)

RC SYSTEMS  6100AL1-0-1020/0030P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,391.48 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.