E2S BExBG21 Explosion and Flame Proof 21 Joule Xenon Beacon suitable for Zone 1, 2, 21 & 22. 520cd. LM6 aluminium enclosure. Glass lens and Stainless Steel guard. IP66/67. IECEx, ATEX, Ex EAC and INMETRO approvals.

ATEX   IECEX   ZONE 1

BEXBG21DPAC115AB1A1R/A   
Please Email us your request for quote   

Voltage
Cable Entries
Stopping plug/adaptor material
Bracket
Version
Color
Metric Adaptor

   2 Weeks  ]
251 Variants of base SKU / 30 Shown below

The flameproof BExBG21 Xenon beacons are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards.

The BExBG21 21 Joule beacons robust construction enables installation in the harshest of environments. The BExBG21 has three distinct user selectable flash patterns and for units with DC operating voltages a second stage flash pattern can be selected remotely. Additional features include a stainless steel guard and stainless steel mounting bracket as standard.

The BEx range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with a chromate and powder coat finish. All models have two M20 cable entries, large termination areas containing in & out terminals and an ingress protection of IP66/67.

Features:
  • Marine grade, corrosion proof, LM6 aluminium enclosure
  • Xenon tubes mechanically secured against shock & vibration
  • Dual Xenon flash tubes
  • G lass lens & Stainless Steel guard
  • Very large termination area.
  • Dual M2 0 cable entries - adaptors available.
  • Stopping plug included.
  • Ratchet adjustable stainless steel ‘U’ bracket.
  • Reverse polarity diode fitted.
  • IP66/67 ingress protection.
  • 52 0 candela effective light intensity.
  • UV stable PC, field replaceable, colour lens filter.
Approvals:

  • IECEx KEM 10.0002 X
    IEC 60079-0 : 2 011
    IEC 60079-1 : 2 007-4
    IEC 60079-31 : 2 013
  • ATEX KEMA 00ATEX2 006X
    EN 60079-0 : 2 012 + A11
    EN 60079-1 : 2 007
    EN 60079-31 : 2 014
  • TR-CU Ex EAC certificate: RU C-G B.AA71.B.00109
  • Inmetro certificate: 10-IEx-0010
Coding
  • II 2 G Ex d IIC T3 G b Ta. -50°C to +70°C
  • II 2 D Ex tb IIIC T150°C Db Ta. -50°C to +40°C
  • II 2 D Ex tb IIIC T165°C Db Ta. -50°C to +55°C
  • II 2 D Ex tb IIIC T180°C Db Ta. -50°C to +70°C

Specification
Energy: 21 Joules
Flash rate: 1Hz, 2 Hz & double strike 1Hz
Peak Candela: 2,100,000 cd – calculated from energy (J)
Effective Intensity cd: 1,050 cd – calculated from energy (J)
Peak Candela: 118,537 cd* - measured ref. to I.E.S.
Effective Intensity cd: 520 cd* – measured ref. to I.E.S.
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Voltages DC: 24vdc; 48vdc
Voltages AC: 115vac; 230vac
Ingress protection: IP66/67
Enclosure matl: Marine grade copper free LM6 Aluminium
Enclosure finish: Chromate & powder coated finish – anti-corrosion.
Colour: RAL3000 Red (others available on request)
Cable entries: Dual M20 ISO (one stopping plug inc)
Terminals: 0.5 – 2.5mm2 (20-14 AWG)
Enclosure volume: <2 litres
Linemonitoring: Blocking diode included EO L Min. 500 O hm 2 w, or 3k3 O hm 0.5w resistor or diode (DC versions) can be added
Grounding stud: M5
Temperature range: -50° to +70°C (-58°F to +158°F)
Relative humidity: 90% at 2 0°C [68°F]
Tube life: Emissions are reduced to 70% after 5 million flashes
Weight: DC: 2 .65kg/5.83Ibs AC: 2 .95kg/6.49Ibs
*All candela data is representative of performance with clear lens at optimum voltage.
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)85311095

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> BEACONS :    125 Items found.
XB13012RNNNNR
(1584)

MEDC  XB13012RNNNNR

MEDC XB13 Xenon beacon (10 Joules), Harsh Industrial & Marine Environments, Weatherproof, IP66 and IP67, designed withhigh ingress protection to cope with harsh environmental conditions, –40°C to +70°C.

MCB00505AC115G-AM/AM
(3635)

E2S  MCB00505AC115G-AM/AM

E2S MCB005-05 Dual 5 Joule Xenon Strobe Beacon with 1Hz flash rate suitable for harsh environments. Robust, fire retardant, IP66 & IP67 housing. Stainless Steel guard and fixings. 24VDC, 115 VAC or 230VAC Versions. GOST-R Approved.

D2xB1LD2DC024MN0H1R/C
(6409)

E2S  D2xB1LD2DC024MN0H1R/C

E2S D2xB1LD2-H Haz Loc auto-synchronizing LED Light/Beacon tested to UL1971. Up to 180cd. 24vdc. Three flashing modes. 2 × 1/2” NPT, 2 x M20x1.5, 1 × 3/4” NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2xB1LD2DC024CN1A1R/C
(6408)

E2S  D2xB1LD2DC024CN1A1R/C

E2S D2xB1LD2 Haz Loc LED Beacon Warning Light tested to UL1638. Up to 180cd. Five flashing modes. Dual 1/2"NPT and dual M20 side entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2xB1X05DC024MN1A1R/C
(6412)

E2S  D2xB1X05DC024MN1A1R/C

E2S D2xB1X05 Haz Loc 5 Joule Xenon Strobe Beacon tested to UL1638. Up to 250cd. 2 x M20x1.5, 2 × 1/2"NPT, 1 × 3/4"NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2xB1X10DC024MN1A1R/C
(6413)

E2S  D2xB1X10DC024MN1A1R/C

E2S D2xB1X10 Haz Loc 10 Joule Xenon Strobe Warning Light tested to UL1638. Up to 500cd. 2 x M20x1.5, 2 × 1/2"NPT, 1 × 3/4"NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

4375S-120_-A
(7228)

TOMAR  4375S-120-A

Tomar Electronics 4375S Hazardous Location Warning Light with 10000 hours xenon strobe lamp. 120-240 VAC model, or 12-74 VDC. NEMA 4X housing. IP66. UL Listed and CSA Certified for Class I, Div 2, Groups A, B, C, and D; Class II, Div 2, Groups F and G; Class III.

Configure

$522.95 
4375L-24_-A
(7227)

TOMAR  4375L-24-A

Tomar Electronics 4375L Hazardous Location Warning Light with 100000 hours LED array. Steady-burn and Single or Double Flash mode. 120-240 VAC model, or 24 VAC/DC. NEMA 4X housing. IP66. UL Listed and CSA Certified for Class I, Div 2, Groups A, B, C, and D; Class II, Div 2, Groups F and G; Class III.

Configure

$545.33 
D2xB1XH1DC024MN0A1R/C
(6410)

E2S  D2xB1XH1DC024MN0A1R/C

E2S D2xB1XH1 Haz Loc 5 Joule Xenon Strobe Beacon tested to UL1971. Up to 250cd. 24vdc. Four flashing modes. 2 x M20x1.5, 2 × 1/2"NPT, 1 × 3/4"NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

FB11W024005CNDNNN
(4188)

MEDC  FB11W024005CNDNNN

MEDC FL11 (Fluorescent) and FB11 (Filament) Steady Beacons, Weatherproof only version, IP66 and IP67, designed for use in potentially explosive atmospheres and harsh environmental conditions.

E2xB05AC115CN1A1B/A
(4421)

E2S  E2xB05AC115CN1A1B/A

E2S E2xB05 5 Joule Xenon Strobe Beacon with 1Hz flash rate suitable for the harshest of environments. PPS & ABS housing. Stainless Steel guard. 24VDC.. UL/cULs Approved for Class I Div 2 and Class 2 Div 2. ATEX and IECEx Approved.

E2xB10AC115CN1A1B/A
(4422)

E2S  E2xB10AC115CN1A1B/A

E2S E2xB10 10 Joule Xenon Strobe Beacon with 1Hz flash rate suitable for the harshest of environments. PPS & ABS housing. Stainless Steel guard. 24VDC. UL/cULs Approved for Class I Div 2 and Class II Div 2. ATEX and IECEx Approved.

E2XBL2AC115CN1A1B/A
(6418)

E2S  E2XBL2AC115CN1A1B/A

E2S E2xBL2 Multi-function LED Beacon & Status Light tested to UL1638A. Up to 160cd. Five flashing modes. Dual M20x1.5 or 1/2"NPT entries. IP66/IP67. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2xB1XH2DC024MN0A1R/C
(6411)

E2S  D2xB1XH2DC024MN0A1R/C

E2S D2xB1XH2 Haz Loc 10 Joule Xenon Strobe Beacon tested to UL1971. Up to 500cd. 24vdc. Four flashing modes. 2 x M20x1.5, 2 × 1/2"NPT, 1 × 3/4"NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

FB11B_024005CNDNNN
(1604)

MEDC  FB11B024005CNDNNN

MEDC FL11 (Fluorescent) and FB11 (Filament) Steady Beacons, Exd, Weatherproof, IP66 and IP67, designed for use in potentially explosive atmospheres and harsh environmental conditions. ATEX Certified, Ex II 2 GD, Ex d IIB T4/T5/T6 Gb. Inmetro, CUTR and IECEx certifications also available.

FB11UL024010RNDNNN
(4187)

MEDC  FB11UL024010RNDNNN

MEDC FB11 (Filament) Steady Beacon (10W bulb), Exd, Weatherproof, IP66 and IP67, designed for use in potentially explosive atmospheres and harsh environmental conditions. UL Listed for Class 1, Div 2, Groups C & D.

FB15UW024060RNDNNNN
(4197)

MEDC  FB15UW024060RNDNNNN

MEDC FB15 (Filament) Steady Beacons, Exd, Weatherproof, IP66 and IP67, designed for use in potentiallyexplosive atmospheres and harsh environmental conditions. UL Listed for ordinary locations version.

BEXBG05E115AC-AM
(3528)

E2S  BEXBG05E115AC-AM

E2S BExBG05E flameproof Xenon Beacon 5 Joule. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22. Glass lens and Stainless Steel guard. Two M20 cable entries. IP66. ATEX, IECEx and GOST-R (2ExdeIICT4).

BEXBG05DPAC115AB1A1R/A
(3527)

E2S  BEXBG05DPAC115AB1A1R/A

E2S BExBG05 Explosion and Flame Proof 5 Joule Xenon Beacon suitable for Zone 1, 2, 21 & 22. LM6 aluminium enclosure. Glass lens and Stainless Steel guard. IP66/67. IECEx, ATEX, Ex EAC and INMETRO approvals.

IS-DL105L-R/R
(6426)

E2S  IS-DL105L-R/R

E2S IS-DL105L 105dB(A) Intrinsically Safe Alarm Sounder and LED Beacon. 49 alarm tones and 3 remotely selectable stages. 2 M20 entries. 24VDC. IP66. ATEX and IECEx approvals.