Xtralis VESDA-E VEP-A00-1P smoke detector with Flair Aspiration detection technology. Includes VESDAnet and Ethernet communication, 7 programmable relays. 18-30 VDC. Suitable for Class 1 Div 2. CSFM, FM, VdS, CE and UL approvals. IP40. Aspirator enables use of a total of 130m (427ft) of sampling pipe in one pipe model and 560m (1,837ft) of pipe in the four pipe model.

RELAYS   UL   FM   DIV 2

VEP-A00-1P-UL   
2,034.39

Display
Pipes

   In Stock  ]
4 Variants of base SKU

The VESDA-E VEP series of smoke detectors bring the latest and most advanced detection technology to provide very early warning and the best nuisance alarm rejection to a wide range of applications. Built on the Flair detection technology and years of application experience, VEP detectors achieve consistent performance over their lifetime via absolute calibration. In addition, the VEP delivers a range of revolutionary features that provide user value.

Flair Detection Technology

Flair is the revolutionary detection chamber that forms the core of the VESDA-E VEP, providing higher stability and increased longevity. Direct imaging of the sampled particles using a CMOS imager combined with multiple photodiodes allows better detection and fewer nuisance alarms.

Installation, Commissioning and Operation

VESDA-E VEP is equipped with a powerful aspirator that enables use of a total of 130m (427ft) of sampling pipe in the one pipe model and 560m (1,837ft) of pipe in the four pipe model. Out of box operation is made possible with AutoConfig which allows airflow normalisation and AutoLearn Smoke and Flow to be initiated from within the detector. VEP is fully supported by the ASPIRE and Xtralis VSC software applications which facilitate ease of pipe network design, system commissioning and maintenance.

VESDAnet™

VESDA devices communicate on VESDAnet which provides a robust bi-directional communication network allowing continued redundant operation even during single point wiring failures. VESDAnet enables primary reporting, centralized configuration, control, maintenance and monitoring.

Ethernet connectivity

VESDA-E detectors offer connectivity to corporate networks via Ethernet, allowing for devices installed with Xtralis monitoring and configuration software to connect to the detector.

Backward Compatibility

VESDA-E VEP is compatible with existing VESDA installations. The detector occupies the same mounting footprint, pipe, conduit and electrical connector positioning as VESDA VLP. VEP is also compatible with existing VESDAnet installations allowing monitoring of both VESDA-E and legacy detectors via the latest VSC and VSM4 applications.

Features
  • Suitable for Class 1 Division 2 applications - Groups A, B, C & D
  • One and four pipe models for different applications
  • Flair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarms
  • Short wavelength laser-based detection:
    • High sensitivity from small particle light scattering
    • No drift compensation required since focused light directed at target gives low backgrounds
    • High stability with temperature and time
  • Multi stage filtration and optical protection with clean air barriers ensures lifetime detection performance
  • Four alarm levels and a wide sensitivity range deliver optimum protection for the widest range of applications
  • Intuitive LCD icon display provides instant status information for immediate response
  • Flow fault thresholds per port accommodate varying airflow conditions
  • Smart on-board filter retains dust count and remaining filter life for predictable maintenance
  • Extensive event log (20,000 events) for event analysis and system diagnostics
  • AutoLearn™ smoke and flow for reliable and rapid commissioning
  • Referencing to accommodate external environmental conditions to minimise nuisance alarms
  • Backward compatible with VLP and VESDAnet
  • Ethernet for connectivity with Xtralis software for configuration, secondary monitoring and maintenance
  • USB for PC configuration, and firmware upgrade using a memory stick
  • Two programmable GPIs (1 monitored) for flexible remote control
  • Field replaceable sub-assemblies enable faster service and maximum uptime
Listings / Approvals
  • CSFM
  • FM
  • VdS
  • NF-SSI (www.marque-nf.com)
  • CE
  • UKCA
  • ActivFire
  • CCC
  • EN 54-20, ISO 7240-20
  • Four Pipe VEP
    -Class A (40 holes / Fire 1 = 0.028% obs/m)
    -Class B (80 holes / Fire 1 = 0.027% obs/m)
    -Class C (100 holes / Fire 1 = 0.056% obs/m)

Specifications
One Pipe VEP Four Pipe VEP
Supply Voltage 18-30 VDC (24 V Nominal)
Aspirator Setting Fixed 1|5 1|5
Power (Quiescent) 8.8 W 7.0 W|9.0 W 8.0 W|10.0 W
Power (In Alarm) 9.6 W 7.8 W|9.8 W 8.8 W|10.8 W
Dimensions (WHD) 350 mm x 225 mm x 135 mm (13.8 in x 8.9 in x 5.3 in)
Weight 4.4 kg (9.7 lbs) 4.4 kg (9.7 lbs) 4.5 kg (9.9 lbs)
Operating Conditions Ambient: 0°C to 38°C (32°F to 100°F)
Sampled Air: -20°C to 60°C (-4°F to 140°F) *
Humidity: 5% to 95% RH, non-condensing
* Sampled Air temperature shall reach Ambient Detector temperature upon entry into Detector. Refer to Xtralis Design Guides & Application Notes for sampled air pre-conditioning.
Area Coverage 1,000 m (10,760 sq. ft) 2,000 m2 (21,520 sq. ft)
Min. airflow per pipe 15 l/m
Pipe Length (Linear) 100 m (328 ft) 280 m (919 ft)
Pipe Length (Branched) 130 m (427 ft) 560 m (1,837 ft)
Pipe lengths depending on number of pipes in use 1 Pipe
100 m (328 ft)
1 Pipe|2 Pipe
110 m (361 ft)|100 m (328 ft)
3 Pipe|4 Pipe
80 m (262 ft)|70 m (230 ft)
StaX PSU
No. of holes (A/B/C) 30/40/45 40/80/100
Computer design tool ASPIRE
Pipe Inlet: External diameter 25 mm or 1.05 in (3/4 in IPS) Exhaust: External diameter 25 mm or 1.05 in (3/4 in IPS) via adaptor
Relays 7 programmable relays (latching or non-latching states)
Contacts rated 2 A @ 30 VDC (Resistive)
IP rating IP40
Cable access 4 x 26 mm (1.02 in) cable entries
Cable termination Screw Terminal blocks 0.2–2.5 sq mm (24–14 AWG)
Measurement Range 0.000 to 32% obs/m (0.0000 to 11.09% obs/ft)
Sensitivity Range 0.005 to 20% obs/m (0.0015% to 6.575% obs/ft)
Threshold setting range Alert: 0.005% to 2.0% obs/m (0.0015% to 0.614% obs/ft)
Action: 0.005% to 2.0% obs/m (0.0015% to 0.614% obs/ft)
Fire1: 0.010% to 2.0% obs/m (0.0030% to 0.614% obs/ft)
Fire2: 0.020% to 20.0% obs/m (0.0061% to 6.575% obs/ft)
Software features Event log: Up to 20,000 events
Smoke level, user actions, alarms and faults with time and date stamp
AutoLearn: Detector learns Alarm Thresholds and Flow Fault thresholds by monitoring the environment.

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping & Handling

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.