Det-tronics Gtxsn26n5 | Det-tronics | Transmitters | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

DET-TRONICS   GTXSN26N5

SKU# (7249)



DET-TRONICS GTXSN26N5
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Det-tronics GTX Electrochemical Toxic Gas Transmitter for GT3000 Series Detectors. Two-wire loop powered. 12-30 VDC. 4-20 mAoutput signal with HART. Explosion proof. IP66. FM/CSA and IECEx approved. Suitable for Class I Div 1, Div 2 and Zone 1.
009480-323

GTXSN26N5   
Please Email us your request for quote   

Threads

   6 Weeks  ]
2 Variants of base SKU
DESCRIPTION

The Det-Tronics GT3000 line of electrochemical gas detectors is designed to provide continuous monitoring of the atmosphere for potentially hazardous gas leaks or oxygen depletion. Models are available for detecting a variety of gas types in various concentration ranges.

The GT3000 toxic gas detector is a two-wire loop powered device and is designed as a stand alone unit that supports local calibration. It is also fully compatible with the FlexVu ® UD10/UD20/UD30 Universal Display Units.

The GT3000 consists of a replaceable sensor module (GTS) connected to a transmitter module (GTX). The transmitter generates a 4-20 mA output signal with HART, which is proportional to the concentration of the target gas and directly corresponds to 0-100% full scale.

The electrochemical sensor cell uses capillary diffusion barrier technology for monitoring gas concentrations in ambient air. When compared to solid state type sensors, the electrochemical sensing element provides improved accuracy, stability and reliability, and can also extend calibration intervals. This results in superior performance and reliability, as well as reduced maintenance.

HIGHLIGHTS
  • Performance approved and verified
  • Electrochemical sensor cell for increased accuracy, stability and reliability
  • Highly specific response reduces the chance of false alarms resulting from the presence of other gases
  • Self-contained transmitter circuitry
  • Temperature compensated to ensure consistent performance over entire operating temperature range
  • Suitable for outdoor applications requiring IP66 rating
  • Hydrophobic filter easily replaced without opening the device or use of tools
  • Hot swappable IS sensor module for live maintenance without de‑classification of hazardous area
  • EMI/RFI hardened
  • Event and calibration logs are stored in non-volatile memory and are accessible using a UD10/UD20/UD30, HART device or AMS software.
  • Real-time clock with battery back-up
  • Magnetic switch and LEDs for user interface

SPECIFICATIONS
Calibration Sensors are calibrated at the factory. Gas type and range are read by the transmitter. Calibration is initiated at the detector, at the UD10/ UD20 Universal Display Unit, or by some other HART interface device. Calibration cannot be initiated from the UD30.
Operating Voltage 24 Vdc nominal; Operating range is 12 to 30 Vdc
Power Consumption 0.8 watt maximum @ 30 Vdc
Max. Loop Resistance 300 ohms at 18 Vdc, 600 ohms at 24 Vdc
Current Output 4-20 mA (Normal operating mode)
3.8 mA indicates calibrate mode
3.5 mA or less indicates a fault condition
Wiring 2x22 AWG, 1x16 AWG, 600V, 20"
Storage Temp. (GTX) –55°C to +75°C (–67°F to +167°F)
(GTS) 0°C to +20°C (+32°F to +68°F) Ideal: +4°C to +10°C (+39°F to +50°F)
Storage Life 6 months in factory-sealed packaging
Humidity Range 15 to 90% RH.
Tropicalization / PC BD Protection Conformal coated printed circuit boards: CTI Rating of 600V, maximum allowed by standard Third party tested per ASTM-D-3638-07
Pressure Range Atmospheric ±10%
Warm-Up Warm-up time can last up to 150 seconds
Thread Options 3/4" NPT or M25
Enclosure Material GTX Transmitter: 316 Stainless Steel
GTS Sensor Module: PPA (30% Carbon filled)
Expected Operating Life GTS: 2 years in an open air environment
Expected Shelf Life GTS: 6 months in factory sealed packaging
Warranty (For the GTX. See Table below for the GTS) 18 months from date of shipment
Certification (Explosion-Proof Model) FM: Class I, Div. 1, Groups A, B, C & D
Class I, Zone 1, Group IIC
IP66
Conduit seal not required
Acidic atmospheres excluded
CSA:
Class I, Div. 1, Groups A, B, C & D (T6)
Class I, Div. 2, Groups A, B, C & D (T6)
IP66
IECEx:
Ex d mb [ia Ga] IIC T4 Gb IP66
IECEx FMG 10.0003X
UL-BR 15.0752X
Ex db mb [ia Ga] IIC T4 Gb IP66
Tamb –40°C to +50°C (H 2 S)
Tamb –20°C to +50°C (other)
Certification (Intrinsically Safe Model) FM: IS Class I, Div. 1, Groups A, B, C & D
Class I, Zone 0, Group IIC
Performance verified per ANSI/ISA
92.00.01 and FM6340
IP66
CSA: Class I, Div. 1, Groups A, B, C & D (T4)
IP66
IECEx:
Ex ia IIC T4 Ga IP66
IECEx FMG 08.0005X
INMETRO:
UL-BR 15.0404X
Ex ia IIC T4 Gb IP66
Tamb –40°C to +50°C
Certification (SIL Approval) IEC 61508
Certified SIL 2 Capable
SIL Certification includes H 2 S, H 2 S+ and O 2 models only
Export Info
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> DET-TRONICS :    16 Items found.
006824-001
(7256)

DET-TRONICS  006824-001

Det-tronics CGS Combustible Gas Sensor for UD10, UD30, DCUEX, U9500A, U8700, K-Series, 400, 405, 505, 500, 810, 820, and 880 Transmitters. Stainless steel catalytic sensor with %LEL range. FM, CSA, ATEX, IECEx and SIL 2 Approvals.

010569-001
(7247)

DET-TRONICS  010569-001

Det-tronics 010569-001 UD10 Display Module. Relay / 4-20 mA Output.



 
010970-004
(7248)

DET-TRONICS  010970-004

Det-tronics 010970-004 UPGRADE KIT UD10S5N25T2. Allows field conversion of a Digital Communication Unit (DCU) to a FlexVu UD10 Universal Display. Adds relay, 4-20 mA, RS485 and HART outputs. FM, CSA, ATEX, IECEx and SIL 2 Approvals.



 
Q9033B1000
(7252)

DET-TRONICS  Q9033B1000

Det-tronics Q9033B Stainless steel Mounting Arm for all X-Series flame detectors (DNV approved with X3301).



 
(7253)

DET-TRONICS  009208-002

Det-tronics 009208-002 oi Replacement Kit for X5200/X9800/X2200. Includes five (5) plates and a W6300B1003. Black Plastic Material.



 
101197-004
(7246)

DET-TRONICS  101197-004

Det-tronics 101197-004 Type A Stop Plug, 3/4" NPT. Stainless Steel. Hex Size 12. 14.8mm.



 
005434-004
(7255)

DET-TRONICS  005434-004

Det-tronics 005434-004 Electrochemical Sensor Cell for Hydrogen Sulfide (H2S) 0-50ppm for use with Model C7064E housings.

010274-003
(7257)

DET-TRONICS  010274-003

Det-tronics GT3000 Certified Calibration Kit for Hydrogen Sulfide (H2S) 0-10 to 0-50ppm. Includes sturdy carrying case containing two cylinders of Class 2.2 non-flammable, non-toxic compressed gas, a 1 liter/minute regulator and pressure indicator, 3-foot tube and GT3000 Calibration Cup.

227117-001
(7258)

DET-TRONICS  227117-001

Det-tronics GT3000 Certified Calibration Gas Kit Replacement Cylinder for Hydrogen Sulfide (H2S) 0-10 to 0-50ppm.

006468-001
(7259)

DET-TRONICS  006468-001

Det-tronics PIRECL, PIR9400, and PIRDUCT Certified Calibration Kit for Methane 0-50% LEL, 2.5% vol. for field calibration of all PointWatch IR detectors. Kit includes Two 3.6 ft 3 (103 liters) cylinders of Class 2.2 non-flammable, non-toxic compressed gas, a 2.5 liter/minute regulator and pressure indicator, 3-foot tube and sturdy plastic carrying case.



 
UD10S5N28W2
(7262)

DET-TRONICS  UD10S5N28W2

Det-tronics FlexVu UD10 Explosion-Proof Universal LCD Backlit Display Unit. 24 VDC. Includes 4–20 mA output with HART, relay contacts, and Modbus RS485. Eventm fault and alarm logs. FM, CSA, ATEX, IECEx and SIL 2 certified for Class I Div 1 and Div 2, Zone 1 and Zone 2.

(7254)

DET-TRONICS  107427-040

Det-tronics 107427-040 O-ring Rear Cover (Viton) for X-Series flame detectors.



 
(7265)

DET-TRONICS  009700-001

Det-tronics 009700-001 Magnetic tool for use with FlexSonic AC100, ATX10, FlexVu UD10, FlexVu UD20 and GT3000 detectors.



 
009640-001
(7261)

DET-TRONICS  009640-001

Det-tronics 009640-001 GTS Replacement Filter for GT3000 Series Detectors.



 
GTSH2S+100PSES
(7251)

DET-TRONICS  GTSH2S+100PSES

Det-tronics GTS Toxic Gas Sensor Module for GT3000 Series Detectors for Hydrogen Sulfide (H2S) 0-100 PPM.



 
(7264)

DET-TRONICS  004532-002

Det-tronics 004532-002 Hydrophobic Replacement Filter for U8800 Controller



 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.