  • LITERATURE
E2S GNExS2 Alarm Horn Sounder with high output with flare re-entrant horn 123dB(A) or High SPL horn 127dB(A). 64 alarm tones, 4 remotely selectable stages/channels. GRP enclosure. IP66. IECEx, ATEX, UL, INMETRO, SIL1 and SIL2 Approvals.

UL   ATEX   IECEX   INMETRO   SIL2

GNExS2FDC024AB1A1R   
Please Email us your request for quote   

Horn type
Voltage
Cable Entries
Stopping plug/adaptor material
Bracket
Product version
Product option
Housing Color
Accesories
Metric Adaptor

 2 Weeks  ]
251 Variants of base SKU / 30 Shown below

The GNExS2H is a very high output 127dB(A) IECEx and ATEX certified alarm horn sounder featuring an enhanced re-entrant flare horn. The robust GRP (glass reinforced polyester) enclosure is approved for Zone 1 & Zone 2 explosion proof signalling applications.

The GNExS2F is a high output IECEx and ATEX certified alarm horn sounder featuring a re-entrant flare horn. The robust GRP (glass reinforced polyester) enclosure is approved for Zone 1 & Zone 2 explosion proof signalling applications.

Featuring 64 alarm tone sounds, each of the available 4 stage/channels can be remotely triggssssered. Class D amplification provides a high sound output with a choice of two power modes. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard.

Features
  • UL 464 (Ed 11) Audible Signaling Devices for Fire Alarm
  • CAN/ULC-S525 (Ed 5) Audible Signaling Devices for Fire Alarm
  • Maximum sound pressure level output of 126dB(A)
  • Choice of 64 alarm tone frequencies
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching
  • Automatic synchronisation on multi-sounder system
  • Ratchet adjustable 316 stainless steel bracket
  • Triple cable entries
  • Available with custom tone configurations and frequencies
  • Robust corrosion proof GRP (glass reinforced polyester) enclosure
Approvals
  • ATEX certificate: SIRA 13ATEX1139X
  • IECEx certificate: IECEx SIR 13.0029X
  • UL certificate: E549307
  • TR-CU Ex EAC certificate: RU C-GB.AA71.B.00109
  • INMETRO IEx 20.0050X
  • SIL1 & SIL2 compliant to IEC61508 (2010)
Coding

IECEx / ATEX

  • II 2G Ex db IIC T3 Ta. -60°C to +58°C (T4: +50°C)
  • II 2G Ex db IIB T5 Ta. -60°C to +58°C (T6: +50°C)

NEC Class Div (24Vdc model)

  • CI Div 2 ABCD T3 Ta -40°C to +58°C (T4: +50°C)
  • CI Div 2 CD T5 Ta -40°C to +58°C (T6: +50°C)

NEC Class I Zone 1 (24Vdc model)

  • AEx db IIC T3 Gb Ta -40°C to +58°C (T4: +50°C)
  • AEx db IIB T5 Gb Ta -40°C to +58°C (T6: +50°C)

CEC Class I Zone 1 (24Vdc model)

  • Ex db IIC T3 Gb Ta -40°C to +58°C (T4: +50°C)
  • Ex db IIB T5 Gb Ta -40°C to +58°C (T6: +50°C)

Specifications
Maximum output GNExS2F
High power level: 123dB(A) @ 1 m +/- 3dB [114dB(A) @ 10ft/3m +/- 3dB]
Default power level: 118dB(A) @ 1 m +/- 3dB [109dB(A) @ 10ft/3m +/- 3dB]
GNExS2H
High power level: 127dB(A) @ 1 m +/- 3dB [118dB(A) @ 10ft/3m +/- 3dB]
Medium power level: 122dB(A) @ 1 m +/- 3dB [113dB(A) @ 10ft/3m +/- 3dB]
Nominal output GNExS2F
High power level: 120dB(A) @ 1 m +/- 3dB [111dB(A) @ 10ft/3m +/- 3dB]
Default power level: 115dB(A) @ 1 m +/- 3dB [106dB(A) @ 10ft/3m +/- 3dB]
GNExS2H
High power level: 124dB(A) @ 1 m +/- 3dB [115dB(A) @ 10ft/3m +/- 3dB]
Medium power level: 119dB(A) @ 1 m +/- 3dB [110dB(A) @ 10ft/3m +/- 3dB]
No. of tones 64 (UKOOA / PFEER compliant)
Stages/Channels 4
No. of stages: GRP (glass reinforced polyester)
Volume control Full range
Effective range GNExS2F: 200m/656ft @ 1KHz
GNExS2H: 350m/1148ft @ 1KHz
Voltages DC 24Vdc (10-60vdc)
Voltages AC 230Vac (100-260Vac)
In-rush 815mA within 4ms @ 24Vdc
Stage switching DC units: positive or negative
AC units: common supply line
Safety Integrity Level GNExS2F:
Product version A: SIL1 and SIL2 Route 2H
Product version S: SIL2 Route 1H with diagnostics SFF: >99%
GNExS2H:
SIL1 and SIL2 Route 2H IEC61508 (2010)
Ingress protection EN60529: IP66
Enclosure material UV stable GRP (glass reinforced polyester)
Enclosure colour: Natural Red
Enclosure finish Natural – can be painted in alternative colours
Cable entries 2 x M20x1.5mm Stopping plug included
Stopping plugs Brass, Nickel Plated or Stainless Steel
Terminals 0.5 – 2.5mm² (20-14 AWG) Pluggable & duplicated terminals
Line monitoring Diode polarized for use in supervised circuits
Blocking diode for reverse polarity monitoring
Ground/Earth stud: M4
Line monitoring Blocking diode included EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor or diode (DC versions) can be fitted
Enclosure volume <2 litres
Installation temp -50° to +70°C (-58°F to +158°F)
Storage temp -50° to +70°C (-58°F to +158°F)
Relative humidity 99%
MTBF DC 93.92 years / 822,706 hours – MIL 217
MTBF AC 46.66 years / 408,508 hours – MIL 217
Weight DC: 3.00kg/6.6Ibs AC: 3.20kg/7.04Ibs
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)85318030

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping & Handling

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORNS :    76 Items found.
A105NAXDC024R-UL
(3273)

E2S  A105NAXDC024R-UL

E2S A105NAX Appello X User Recordable Alarm Sounder 102dB(A). Low current consumption. 10-30VDC or 90-250VAC Versions. Robust fire retardant Type 4/4X/3R/13, IP66 housing. UL approved.

IS-A105N-G
(3687)

E2S  IS-A105N-G

E2S IS-A105N high output Alarm Sounder 105dB(A). 16-28VDC. Stainless Steel fixings. IP66. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class I Div 1 and Class I Zone 0.

A112NDC_24R
(3274)

E2S  A112NDC24R

E2S A112N high output Alarm Sounder 119dB(A). High SPL. 24VAC, 115VAC, 230VAC, 24V, 48V or 100/230V Versions. Stainless steel fixings. Programmable version available. IP66. VdS, GOST-R and MED Approved. UL version available.

IS-PA1-G
(3692)

E2S  IS-PA1-G

E2S IS-pA1 compact Panel Mount Sounder 90dB(A). 16-28VDC. Produces a high frequency continuous tone. Ideal for control panels. IP66. ATEX, IECEx and GOST-R approved.



 
HA105NDC024G
(3654)

E2S  HA105NDC024G

E2S HA105N Electronic Siren, Buzzer, Claxon and Bell 112dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC or 230VAC Versions. IP66. GOST-R approved.

MA112DC024G
(3606)

E2S  MA112DC024G

E2S MA112 Alarm Horn Sounder 119dB(A). High output. With robust and fire retardant IP66 & IP67 housing. Suitable for harsh environments. Automatic synchronisation and Stainless Steel fixings. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. GOST-R Approved.

HA121DC024R
(3648)

E2S  HA121DC024R

E2S HA121 Electronic Siren, Buzzer, Claxon and Bell 121dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66. GOST-R approved.

D105DC024R
(5126)

E2S  D105DC024R

E2S D105 high output, 112dB(A) Alarm Sounder. Low current consumption and high SPL. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. Marine grade aluminium housing. Stainless steel fixings. Programmable version available. IP66. UL & cULs approved.

A121DC_24R
(3277)

E2S  A121DC24R

E2S A121 very high output Alarm Sounder 126dB(A). High SPL. 24VAC, 115VAC, 230VAC, 24V or 48V Versions. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. UL version available.

A121AXDC024R-UL
(3281)

E2S  A121AXDC024R-UL

E2S A121AX Appello X User Recordable Alarm Sounder 112dB(A). Low current consumption. 10-30VDC or 90-250VAC Versions. Robust fire retardant Type 4/4X/3R/13, IP66 housing. UL approved.

HMA121DC024G
(3652)

E2S  HMA121DC024G

E2S HMA121 Electronic Siren, Buzzer, Claxon and Bell 124dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66 & IP67. GOST-R approved.

D112DC024R
(5127)

E2S  D112DC024R

E2S D112 high output, 119dB(A) Alarm Sounder. Low current consumption and high SPL. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. Marine grade aluminium housing. Stainless steel fixings. Programmable version available. IP66. VdS, UL & cULs approved.

IS-D105-G
(6425)

E2S  IS-D105-G

E2S IS-D105 105dB(A) intrinsically safe Alarm Sounder. 49 alarm tones and 2 remotely selectable stages. 2 M20 entries. 24VDC. IP66. ATEX and IECEx approvals.

E2xS112FDC024A1A1B
(4423)

E2S  E2xS112FDC024A1A1B

E2S E2xS112 Alarm Sounder/Horn 116dB(A). Suitable for all general signalling duties in the harshest of environments. PPS & ABS high impact housing. 24VDC, 115VAC or 230VAC Versions. UL/cULs Approved for Class I Div 2 and Class II Div 2. ATEX ... more

MV121DC024G-UL
(3608)

E2S  MV121DC024G-UL

E2S MV121 Appello X User Recordable Alarm Sounder 126dB(A). Low current consumption. With robust and fire retardant IP66 & IP67 housing. Volume Control. 14-30VDC or 90-260VAC Versions. UL and cULs Approved.

E2XS121FDC024A1A1B
(4424)

E2S  E2XS121FDC024A1A1B

E2S E2xS121 Alarm Sounder/Horn 121dB(A). Suitable for all general signalling duties in the harshest of environments. PPS & ABS high impact housing. 24VDC. UL/cULs Approved for Class I Div 2 and Class II Div 2. ATEX and IECEx Approved.

D2XS1AC115CN1A1G
(4426)

E2S  D2XS1AC115CN1A1G

E2S D2xS1 Alarm Horn Sounder 116dB(A). Low current consumption and high SPL. Type 4/4X, IP66 enclosure. Suitable for all haz loc applications. 4 remotely selectable alarm stages. 64 alarm tone frequencies. UL approved for Class I Div 2 and Class ... more

E2XS1FDC024CN1A1B
(6423)

E2S  E2XS1FDC024CN1A1B

E2S E2xS1F 116dB(A) Alarm Sounder for hazardous locations. 45 alarm tones and 3 remotely selectable stages. Dual M20x1.5 or 1/2"NPT entries. IP66. UL/cULs approved for Class I/II Div 2 and Class I Zone 2/22. ATEX and IECEx approvals.

MA2FDC024CN1A1G
(3607)

E2S  MA2FDC024CN1A1G

E2S MA2F Alarm Horn Sounder 123dB(A). High output. Robust and fire retardant IP66 & IP67 housing. Automatic synchronisation. M20 or 1/2"NPT cable entries. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. 64 alarm tone frequencies.

E2XS2FDC024CN1A1B
(6424)

E2S  E2XS2FDC024CN1A1B

E2S E2xS2F 121dB(A) Alarm Sounder for hazardous locations. 45 alarm tones and 3 remotely selectable stages. Dual M20x1.5 or 1/2"NPT entries. IP66. UL/cULs approved for Class I/II Div 2 and Class I Zone 2/22. ATEX and IECEx approvals.

Page: 1 | 2 | 3 | 4 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.