Notifier Fsv-951r | Intelligent | Smoke | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   FSV-951R

NOTIFIER FSV-951R
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier FSV-951R Series Very Intelligent Plug-in Early Warning (VIEW®) Laser Smoke Detector. 0.03% to 1.00% (CLIP) or 0.02% to 2.00% (other) sensivity. With FlashScan and CLIP protocol systems. Advanced laser light source and 360° viewing angle. Optional relay, isolator and sounder bases. UL and MEA listed. FM, CSFM, BSMI and CCCF Approved. (replaces FSL-751)

FSV-951R   
Please Email us your request for quote   

Intelligent Bases

   4 Weeks  ]

The NOTIFIER FSV-951R VIEW is high-sensitivity photoelectric smoke detectors designed for Very Early Warning Fire Detection and will protect valuable assets and operations where systems must remain functioning at all times.

FSV-951R VIEW detector features a smoke-sensing chamber and patented optic block designed to amplify signals from smoke, but diminish stray internal reflections that can cause false alarms. New LED technology allows this detector to achieve sensitivity levels from 0.02 percent-per-foot to 2 percent-per-foot obscuration – up to 25 times greater than a standard photoelectric detector. The extensive software processing includes multi-alert drift compensation, internal self-diagnostics, and superior transient signal rejection algorithms to produce unprecedented stability at ultra-high sensitivities across the full temperature range. This system provides point identification of the fire location through addressability and offers complete supervi- sion of both the wiring and detector.

FSV-951R VIEW detector features a smoke-sensing chamber and patented optic block designed to amplify signals from smoke, but diminish stray internal reflections that can cause false alarms. New LED technology allows this detector to achieve sensitivity levels from 0.02 percent-per-foot to 2 percent-per-foot obscuration – up to 25 times greater than a standard photoelectric detector. The extensive software processing includes multi-alert drift compensation, internal self-diagnostics, and superior transient signal rejection algorithms to produce unprecedented stability at ultra-high sensitivities across the full temperature range. This system provides point identification of the fire location through addressability and offers complete supervi- sion of both the wiring and detector.

FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier for high speed communication between analog intelligent devices. Intelligent devices commu- nicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other protocols.

Using the enhanced intelligent sensing algorithms, the intelli- gent sensing system provides drift compensation (meeting UL requirements as a calibrated sensitivity meter), maintenance alert (3 levels), selection of 9 alarm levels and 9 pre-alarm lev- els, and report of drift compensation used and recent peak val- ues. The system includes a self-learn sensitivity adjustment to set the pre-alarm level just above the peak levels sensed over long periods of time for each detector’s actual environment. The system includes multi-detector algorithms that permit one sensor to consider readings from adjacent sensors to provide faster detection of fires.

  • UL 268 listed for Open Air Protection (0.5%/ft. to 2.0%/ft. obscuration)
  • UL 268 listed for Special Applications (0.02%/ft. to 0.5%/ft. obscuration)
  • UL 268A listed for Duct Applications allowing both in duct and within System Sensor models DNR and DNRW duct smoke detectors

In addition, the new modern profile blends seamlessly with other 900 series detectors, which offer expanded color options to meet con- temporary aesthetic demands.

VIEW is the ideal detection solution for sensitive environments that cannot tolerate even small amounts of smoke:

  • Telecommunications switching facilities
  • Cellular telephone infrastructure
  • Integrated circuit fabrication facilities
  • Computer rooms
  • Traffic control centers
  • Data Centers
Features

  • Superior EMI protection
  • Very Early Warning Fire Detection capability
  • Analog communications
  • Low standby current
  • Rotary address switches
  • 360° visibility of device status with dual LEDs
  • On-board drift compensation
  • Transient rejection algorithms
  • Microprocessor design
  • FlashScan® or CLIP protocol communications
  • New modern profile with expanded color options

PHYSICAL/OPERATING SPECIFICATIONS
Dimensions: Height: 2.0 inches (51 mm) installed in B300-6/-IV base
Diameter: 6.2 inches (156 mm) installed in B300-6/-IV base;
4.1 inches (104 mm) installed in B501-WHITE/-IV/-BL base
Weight: 3.4 oz (95 g)
Operating Temperature Range: 32°F to 122°F (0°C to 50°C)
Operating Humidity Range: 10% to 93% relative humidity, non condensing
Air Velocity: 0 to 4,000 fpm (0 to 1219 m/minute)
Isolator Load Rating: 0.0063*
Self Diagnostics: Initiated by control panel; activated by test magnet
Smoke Sensitivity: 9 levels: 0.02, 0.03, 0.05, 0.10, 0.20, 0.50, 1.00, 1.50, 2.00%/ft. obscuration (0.06, 0.10, 0.16, 0.33, 0.66, 1.65, 3.24, 4.85, 6.41%/m obscuration)
Drift Compensation: High sensitivity maintenance alert signal
Low sensitivity maintenance alert signal
Maintenance urgent signal
ELECTRICAL SPECIFICATIONS
Operating Voltage Range: 15 to 32 VDC
Operating Current @ 24 VDC: 300 μA (one communication every 5 seconds with green LED blink on communication)
Maximum Current: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on)
aa aa
Maximum Alarm Current: 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on)
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

FST-951
(3228)

NOTIFIER  FST-951

Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360° viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

FSP-951
(2038)

NOTIFIER  FSP-951

NOTIFIER by Honeywell FSP-951 Series Intelligent Plug-in Photoelectric Smoke Detector (0.5% to 4% per foot obscuration) with FlashScan and CLIP communication protocol systems. Addressable-analog communication. Optional relay, isolator and sounder bases. UL, ULC, FM and CSFM Approvals. *** Replaces FSP-851 ***

ISO-X
(3235)

NOTIFIER  ISO-X

Notifier ISO-X Fault Isolator Module for Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). Powered by SLC loop. High noise immunity. UL, FM, CSFM, MEA and BSA Approved.



 
FCO-951
(3502)

NOTIFIER  FCO-951

Notifier IntelliQuad® PLUS FCO-951 Advanced Multi-Criteria Fire/CO Detector with four unique sensing elements: Carbon Monoxide (CO) electrochemical sensor, Infrared (IR) sensing measure, Photo-electric smoke detection and Thermal detection. UL listed. *** replaces FSC-851 ***



 
NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol. *** UNPREDICTABLE LEAD TIME ****

> INTELLIGENT :    10 Items found.
B110LP
(7064)

NOTIFIER  B110LP

Notifier B110LP Plug-in Smoke Detector with photoelectric sensor for a wide range of combustion sources. Includes Low current draw, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. UL, ULC, FM and MEA approved.

4098-9733
(6852)

TYCO  4098-9733

Tyco Simplex 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

Configure

$25.86 
4098-9714
(6845)

TYCO  4098-9714

Tyco Simplex 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

2W_-B
(6927)

NOTIFIER  2W-B

NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. Wide angle and dual color LED indicator. Mounting base included. UL, FM, and CSFM Approved.

4098-9601
(7076)

TYCO  4098-9601

Tyco Simplex 4098-9601 TrueAlarm Photoelectric Intelligent Smoke Detector. 2.8%/ft or 3.5%/ft nominal sensivity. 2-wire or 4-wire operation. Ceiling or wall mounting. Includes alarm relay output and multi-function incator LED. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4098-9757
(7073)

TYCO  4098-9757

Tyco Simplex 4098-9757 QuickConnect2 TrueAlarm Analog Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet communications. Ceiling or wall mounting. NEMA 1. UL Approved.

Configure

$61.78 
FPTI-951
(6825)

NOTIFIER  FPTI-951

NOTIFIER by Honeywell FPTI-951 Multi-Criteria Photo/Thermal/Infrared Detector with FlashScan and CLIP protocol systems. Dual LEDs for 360° visibility. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FAPT-851 ***

DNR
(6866)

NOTIFIER  DNR

Notifier DNR intelligent Photoelectric Duct Smoke Detector for mounting to round or rectangular ducts. Non-Relay. Optional NEMA-4 watertight enclosure. Air velocity rating from 100 ft/min to 4,000 ft/min. Remote testing capability. UL, ULC, CSFM and FM approved.

4098-9756
(7075)

TYCO  4098-9756

Tyco Simplex 4098-9756 Addressable Duct Sensor Housing with TrueAlarm Photoelectric Smoke Sensor. Includes relay, supervised output for multiple remote relays and 2 diagnostic LEDs. IDNet and MAPNET II communications. UL listed (requires separate 24 VDC fire alarm power).



 
FS-OSI-RI
(6933)

NOTIFIER  FS-OSI-RI

Notifier FS-OSI-RI Intelligent Addressable Single-ended Reflective Imaging Beam Smoke Detector suited for large open areas with high ceilings. 24 VDC. 12° field of view. Status LED indicators. UL and FM approved.



 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.