Gasdetectorsusa.com: Sample Draw - All
Acd, Aimsafety, Ams, Analytical Technology, Automation Direct, Autronica, Bw, Calibration Technologies, Cool Air, Delphian, Detcon, Det-tronics, E2s, Esp Safety, Felix, Fhf, Forensics Detectors, Gas Clip, Gas Detectors Usa, Gasco, Gds, Harvard, Honeywell, Industrial Scientific, Infrared Industries, Intec, Interscan, Ion Science, Ivc, Kwikdraw, Macurco, Medc, Mpower, Mru, Notifier, Nova, Portagas, Prosense, Rc Systems, Rhino, Simplex Tyco, Simtronics, Solo, Spectrex, System Sensor, Tomar, Uniphos, United Security
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
SAMPLE DRAW > all :    13 Items found.
GDS-58BX-0-10-04-00-00/0-0
(3314)

GDS  GDS-58BX-0-10-04-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Oxygen (O2) with range 0-25% Vol. Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1.

Configure

$5,020.00 
GDS-58BX-0-19-05-00-00/0-0
(3330)

GDS  GDS-58BX-0-19-05-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Sulfur Dioxide (SO2) with range 0-50 to 0-500 ppm. Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1.

Configure

$5,035.00 
GDS-58BX-0-15-04-00-00/0-0
(3329)

GDS  GDS-58BX-0-15-04-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Hydrogen Sulfide (H2S) with range 0-25 to 0-5000 ppm. Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1.

Configure

$5,075.00 
GDS-58BX-0-14-19-00-00/0-0
(3328)

GDS  GDS-58BX-0-14-19-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Hydrogen (H2) with range 0-1% or 0-4% vol. Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1.

Configure

$5,090.00 
GDS-58BX-0-11-06-00-00/0-0
(3327)

GDS  GDS-58BX-0-11-06-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Carbon Monoxide (CO) with range 0-100 to 0-9999 ppm. Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1.

Configure

$5,100.00 
GDS-58BX-0-29-05-00-00/0-0
(3336)

GDS  GDS-58BX-0-29-05-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured Nitrogen Dioxide (NO2) with range 0-50 ppm to 0-400 ppm. Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1.

Configure

$5,110.00 
GDS-58BX-0-70-06-00-00/0-0
(3343)

GDS  GDS-58BX-0-70-06-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit). Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, Ethanol, MEK, Propane, Propylene, Pentane and many others.

Configure

$5,185.00 
GDS-58BX-0-70-06-15-04/0-0
(3347)

GDS  GDS-58BX-0-70-06-15-04/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit) and Hydrogen Sulfide (H2S). Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others.

Configure

$6,595.00 
GDS-58BX-0-132-02-00-00/0-0
(3346)

GDS  GDS-58BX-0-132-02-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Carbon Dioxide (CO2) with range 0-2% v/v to 0-100% v/v. Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1.

Configure

$7,315.00 
GDS-58BX-0-127-06-00-00/0-0
(3345)

GDS  GDS-58BX-0-127-06-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Ethylene Oxide (ETO) with range combustible 0-50% LEL (Lower Explosive Limit). Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1.

Configure

$7,315.00 
GDS-58BX-0-110-06-00-00/0-0
(3344)

GDS  GDS-58BX-0-110-06-00-00/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit). Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Exane, Jet-A, Diesel, Gasoline, Isopropyl Alcohol and others.

Configure

$7,315.00 
GDS-58BX-0-132-02-10-04/0-0
(3349)

GDS  GDS-58BX-0-132-02-10-04/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Carbon Dioxide (CO2) with range 0-5% v/v or 0-3.5% v/v and Oxygen (02) with range 0-25%. Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1.

Configure

$7,620.00 
GDS-58BX-0-110-06-15-04/0-0
(3348)

GDS  GDS-58BX-0-110-06-15-04/0-0

GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit) and Hydrogen Sulfide (H2S). Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Exane, Jet-A, Diesel, Gasoline, Isopropyl Alchohol and others.

Configure

$7,675.00 