Acd, Aimsafety, Ams, Analytical Technology, Automation Direct, Autronica, Bw, Calibration Technologies, Cool Air, Delphian, Detcon, Det-tronics, E2s, Esp Safety, Felix, Fhf, Forensics Detectors, Gas Clip, Gas Detectors Usa, Gasco, Gds, Harvard, Honeywell, Industrial Scientific, Infrared Industries, Intec, Interscan, Ion Science, Ivc, Kwikdraw, Macurco, Medc, Mpower, Mru, Notifier, Nova, Portagas, Prosense, Rc Systems, Rhino, Simplex Tyco, Simtronics, Solo, Spectrex, System Sensor, Tomar, Uniphos, United Security
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
GAS DETECTORS (EXPLOSION-PROOF) > all :    71 Items found.
965-015420-100
(5007)

DETCON  965-015420-100

Detcon MicroSafe TP-524D Smart gas detection Sensor designed to detect and monitor Hydrogen Sulfide (H2S) with range 0-100ppm using solid state metal oxide semiconductor technology. Aluminum Junction Box. 4-20 mA output. LED Display. Explosion Proof. IP66. ATEX, ISA and CE Approved. CSA and FM Approved for Class I, Div 1, Groups B, C, & D. Optional HART.

965-525420-100
(5006)

DETCON  965-525420-100

Detcon MicroSafe FP-524D Smart gas detection Sensor designed to detect and monitor combustible gases with range 0-100% LEL using matched-pair catalytic bead sensor technology. Aluminum Junction Box. 4-20 mA output. LED Display. Explosion Proof. IP66. CSA and ISA Approved for Class I, Div 1, Groups B, C, & D. Optional HART.

961-440026-100C
(2131)

DETCON  961-440026-100C

Detcon DM-100-CO Electrochemical Carbon Monoxide (CO) 0-100ppm SensorAssembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-750026-005C
(6351)

DETCON  961-750026-005C

Detcon DM-100-Br2 Electrochemical Bromine (Br2) 0-5ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-940026-100C
(6370)

DETCON  961-940026-100C

Detcon DM-100-NO Electrochemical Nitric Oxide (NO) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-190026-001C
(6350)

DETCON  961-190026-001C

Detcon DM-100-AsH3 Electrochemical Arsine (AsH3) 0-1ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-240026-100C
(2132)

DETCON  961-240026-100C

Detcon DM-100-H2S Electrochemical Hydrogen Sulfide (H2S) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

967-444490-0100A
(6074)

DETCON  967-444490-0100A

Detcon DM-700-CO Electrochemical Smart Carbon Monoxide (CO) 0-100 ppm/0-200 ppm Sensor Assembly with LED display. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div 1, Groups B, C, & D. CSA and ATEX approvals. Optional Alarm Relays, HART.

967-242490-100A
(6064)

DETCON  967-242490-100A

Detcon DM-700-H2S Electrochemical Smart Hydrogen Sulfide (H2S) 0-100 ppm Sensor Assembly with LED display. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div 1, Groups B, C, & D. CSA and ATEX approvals. Optional Alarm Relays, HART.

967-343490-25PA
(6065)

DETCON  967-343490-25PA

Detcon DM-700-O2 Electrochemical Smart Oxygen (O2) 0-25% Sensor Assembly with LED display. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div 1, Groups B, C, & D. CSA and ATEX approvals. Optional Alarm Relays, HART.

961-090026-030C
(6365)

DETCON  961-090026-030C

Detcon DM-100-HCL Electrochemical Hydrogen Chloride (HCl) 0-30ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-070026-01PC
(6053)

DETCON  961-070026-01PC

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-1%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-770026-001C
(6354)

DETCON  961-770026-001C

Detcon DM-100-CLO2 Electrochemical Chlorine Dioxide (ClO2) 0-1ppm or 0-50ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-ED0026-100C
(6357)

DETCON  961-ED0026-100C

Detcon DM-100-C2H4 Electrochemical Ethylene (C2H4) 0-100ppm or 0-200ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-EZ0026-100C
(6378)

DETCON  961-EZ0026-100C

Detcon DM-100-C2H5SH Electrochemical Ethyl Mercaptan (C2H5SH) 0-100% LEL Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-270026-001C
(6359)

DETCON  961-270026-001C

Detcon DM-100-F2 Electrochemical Fluorine (F2) 0-1ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-EP0026-100C
(6360)

DETCON  961-EP0026-100C

Detcon DM-100-CH2O Electrochemical Formaldehyde (CH2O) 0-100ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-080026-030C
(6364)

DETCON  961-080026-030C

Detcon DM-100-HBr Electrochemical Hydrogen Bromide (HBr) 0-30ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-130026-030C
(6366)

DETCON  961-130026-030C

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

961-330026-010C
(6367)

DETCON  961-330026-010C

Detcon DM-100-HF Electrochemical Hydrogen Fluoride (HF) 0-5/0-10ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.