E2s Gnexs2dc024ab1a1r | Horns | Zone 1 And Zone 2 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   GNEXS2DC024AB1A1R

E2S GNEXS2DC024AB1A1R
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S GNExS2 flameproof 123dB(A) Alarm Horn Sounder. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

GNEXS2DC024AB1A1R   
Please Email us your request for quote   

Voltage
Cable Entries
Stopping plug/adaptor material
Bracket
Metric Adaptor

   2 Weeks  ]
251 Variants of base SKU / 30 Shown

The flameproof GNExS2 alarm sounder is suitable for Zone 1 & Zone 2 applications – certified to ATEX and IECEx. Sound level outputs up to 123dB(A) at 1 metre with a choice of 64 alarm tones and 4 remotely selectable stages.

The alarm tone frequencies for the first 2 stages are independently selectable. The GNEx range features enclosures manufactured from GRP (glass reinforced polyester), moulded in natural red, but also available in other colours.

The re-entrant flare horn is high impact, fire retardant ABS. All models contain dual cable entries, large termination areas containing in & out terminals and an ingress protection of IP66/67. SIL1 compliant to IEC61508 (2010) as standard.

Features:
  • Automatic synchronisation on multi-sounder system.
  • Very large termination area.
  • Ratchet adjustable stainless steel ‘U’ bracket.
  • IN & OUT terminals.
  • Independently selectable tones for 1st & 2nd stages.
  • Four remotely switched stages/channels.
  • SIL1 compliant to IEC61508 (2010).
Approvals:

  • ATEX certificate: SIRA 13ATEX1139X,
    EN 60079-0 : 2012, EN 60079-1 : 2007
  • IECEx certificate: IECEx SIR 13.0029X,
    IEC 60079-0 : 2011 (Ed6), IEC 60079-1 : 2007 (Ed6)
  • TR-CU Ex EAC certificate: RU C-GB.AA71.B.00109
Coding
  • II 2G Ex d IIC T4 Ta. -60° to +50°C
  • II 2G Ex d IIC T3 Ta. -60° to +58°C
  • II 2G Ex d IIB T6 Ta. -60° to +50°C
  • II 2G Ex d IIB T5 Ta. -60° to +58°C

Specification
Maximum output: 123dB(A) @ 1 metre [114dB(A) @ 10ft/3m]
Nominal output: 117dB(A) @ 1m +/- 3dB – Tone 2 [108dB(A) @ 10ft/3m]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Max. 117dB(A); Min. 108dB(A) – Tone 44
Effective range: 200m/656ft @ 1KHz
Voltages DC: 24vdc (10-30vdc), 48vdc (38-60vdc)
Voltages AC: 230vac (100-260vac/dc)
Stage switching: Negative or positive
Ingress protection: IP66/67
Enclosure matl: GRP (glass reinforced polyester)
Colour: RAL3000 Red (others available on request)
Flare matl: High impact UL94 V0 & 5VA FR ABS (Red)
Cable entries: Dual M20 ISO
Terminals: 0.5 to 2.5mm2 cables.
Enclosure volume: <2 litres
Line monitoring: Blocking diode included EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted
Relative humidity: 95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight: DC: 3.35kg/7.37Ibs AC: 3.55kg/7.81Ibs
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)85318030

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORNS :    73 Items found.
BEXS120E_12DC
(3658)

E2S  BEXS120E12DC

E2S BExS120E flameproof Alarm Horn Sounder 123dB(A). LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66. ATEX, IECEx, GOST-R (2ExdeIICT4), VdS, CPD, SIL1 and Inmetro Approved.

DB3BD_G_0481BNNNNN
(4227)

MEDC  DB3BDG0481BNNNNN

MEDC DB3B Sounder (up to 125dB(A)) with 28 output tones. Exd(e), Weatherproof. IP66 & IP67. NEMA 4X & 6. Designed to be used on potentially explosive gas and dust atmospheres. -55C to +70C. ATEX Certified, Ex d. CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,268.26 
DB3BULG_0481BNNNNN
(4229)

MEDC  DB3BULG0481BNNNNN

MEDC DB3B Sounder (up to 125dB(A)) with 28 output tones. Exd(e), Weatherproof. IP66 & IP67. NEMA 4X & 6. Designed to be used on potentially explosive gas and dust atmospheres. -55C to +70C. UL Hazardous & Ordinary Locations certified for Class I, Division 1. Groups A-D.

Configure

$1,268.26 
BEXDS120E_12DC
(3660)

E2S  BEXDS120E12DC

E2S BExDS120E flameproof Alarm Horn Sounder 123dB(A). LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66. ATEX, IECEx, GOST-R (2ExdeIICT4), VdS, CPD, SIL1 and Inmetro Approved.

GNEXS1DC024AB1A1R
(6440)

E2S  GNEXS1DC024AB1A1R

E2S GNExS1 flameproof 117dB(A) Alarm Horn Sounder. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

GNEXS1RDC024AB1A1R
(6441)

E2S  GNEXS1RDC024AB1A1R

E2S GNExS1-R flameproof 115dB(A) Radial Alarm Horn Sounder with Omni-directional sound output. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

DB3_VE_NNN1B_N
(4180)

MEDC  DB3VENNN1BN

MEDC DB3V Sounder (up to 110 dB(A)), Zone 1, Zone 2 and non-Ex use, Exd(e), Weatherproof, IP66 and IP67, intended for use in potentially explosive gas and dust atmospheres. -55C to +70C. ATEX approved Ex II 2GD, EExde IIC T5. CUTR and Inmetro certifications also available.

DB3BD_E_0481BNNNNN
(4228)

MEDC  DB3BDE0481BNNNNN

MEDC DB3B Sounder (up to 125dB(A)) with 28 output tones. Exd(e), Weatherproof. IP66 & IP67. NEMA 4X & 6. Designed to be used on potentially explosive gas and dust atmospheres. -55C to +70C. ATEX Certified, Ex de. CUTR, IECEx, Inmetro and CQST versions also available.

DB3_VD_NNN1B_N
(1608)

MEDC  DB3VDNNN1BN

MEDC DB3V Sounder (up to 110 dB(A)), Zone 1, Zone 2 and non-Ex use, Exd(e), Weatherproof, IP66 and IP67, intended for use in potentially explosive gas and dust atmospheres. -55C to +70C. ATEX Certified Ex II 2GD, Ex d IIC T4/T5 Gb, Ex tb IIIC T100°C/T135°C Db. CUTR, Inmetro and CQST certifications also available.

STEXS1RDC024AS2A1R
(6458)

E2S  STEXS1RDC024AS2A1R

E2S STExS1R 115dB(A) Alarm Horn Sounder with omni-directional horn. IP66 corrosion proof 316L stainless steel enclosure. 64 channel alarm sounds. 3 cable entries. Remotely triggering. Suitable for All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

STEXS1FDC024AS2A1R
(5143)

E2S  STEXS1FDC024AS2A1R

E2S STExS1F 117dB(A) Alarm Horn Sounder with re-entrant flare horn. IP66 corrosion proof 316L stainless steel enclosure. 64 channel alarm sounds. 3 cable entries. Remotely triggering. Suitable for All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

STEXS2FDC024AS2A1R
(6459)

E2S  STEXS2FDC024AS2A1R

E2S STExS2F 123dB(A) Alarm Horn Sounder with re-entrant flare horn. IP66 corrosion proof 316L stainless steel enclosure. 64 channel alarm sounds. 3 cable entries. Remotely triggering. Suitable for All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

A141DC024G
(3637)

E2S  A141DC024G

E2S A141 High Level Audible Warning System 141dB(A). High output. Ideal for wide area and disaster warning applications. 4 100W drivers. 24VDC or 230VAC Versions. IP65. GOST-R Approved.

Page: 1 | 2 | 3 | 4 | All
Cookie Notice