MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. UL Class 1, Division 1 Gas groups B, C & D or UL Class 1, Division 2. Gas groups A - D.

PH1UL11M3MSNNNR   
1,879.54

Certification
Entries
Entries
Switches
Options
Options
Options
Finish

   9 Weeks  ]
251 Variants of base SKU / 30 Shown

The PH1 double action pull handle call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where light weight combined with a high level of corrosion resistance is required.

The large "Lift" and "Pull" GRP handles can be operated effortlessly whilst wearing industrial gloves and require double action to raise the alarm, preventing accidental activation.

FEATURES

  • Zone 1 and Zone 2 use.
  • UL Listed for:
    • Hazardous Locations.
    • Class I, Division 1. Groups B, C & D.
    • Class I, Division2. Groups A-D.
    • Zone 1.
    • Ordinary Locations: Fire alarm boxes.
  • Ex d IIC T6 Gb.
  • Ex tb IIIC T85oC Db.
  • IECEx certified Gb, Db.
  • ATEX certified Ex II 2 GD.
  • NEMA 4X & 6. IP66 & IP67.
  • Certified temperature: -55oC to +70oC*.
  • Corrosion free GRP construction.*
  • Optional in line, end of line resistors and diodes.
  • Retained stainless steel cover screws.

Certification and Specification
UL Haz Locs: UL listed for USA and Canada.
Listing no. E186629.
Class I, Div. 1. Groups B, C & D.
Class I, Div. 2. Groups A- D.
Class I, Zone 1, AEx d IIC, Ex d IIC.
Class II, Div.2, Groups F & G.
Class III.
UL Ord Locs: UL Listing no. S8117. Fire alarm boxes.
UL for USA and Canada.
IECEx Ex d: Cert. no. IECEx ITS.11.0021X.
Certified to: IEC60079-0, IEC60079-1, IEC60079-31.
Ex d IIC T6 Gb, Ex tb IIIC T85oC Db. IP66.
ATEX Ex d: Cert. no. ITS11ATEX17308X.
Certified to: EN60079-0, EN60079-1, EN60079-31.
Ex II 2 GD, Ex d IIC T6 Gb, Ex tb IIIC T85oC Db. IP66.
Material: Body/covers/handles:- GRP (glass reinforced polyester).
UL Class I, Div. 1 Inner Cover: 316 (ANC4B) Stainless Steel.
Fixings:- Stainless steel grade 316.
Finish: Cover:- natural red, Body:- natural black.
Handles:- natural white.
Cover may be painted to customer's requirements.
Voltage: 0-50Vdc, 0-254Vac.
Switch Rating: 1 or 2 c/o switches, 254V, 3A max.
Weight: UL Class I, Div 2, ATEX, IECEx & UW: Gross weight 3.2Kg.
Net weight 2.6Kg.
UL Class I, Div. 1: Gross weight 4.4 Kg. Net weight 3.8Kg.
Certified Temp: ATEX & IECEx: -55oC to +70oC. UL Class I, Divs. 1 & 2, UW: -50oC to +70oC
Ingress Protection: NEMA 4X & 6. IP66 & IP67.
Entries: UL Class I, Div. 1 - Max 1 per face. Up to 2 x 1 / 2 ” NPT or 3 / 4 ” NPT.
Positions 2 & 5 only.
UL Class I, Div. 2, UW: Up to 2 x 1 / 2 ” or 3 / 4 ” NPT. 3 / 4 ” NPT,
Max. 1 per face & positions 2 & 5 only.
ATEX, IECEx - Max 2 per face. Up to 2 x M20 or M25, up to 2 x 1 / 2 ” or 3 / 4 ” NPT.
Please note that certified blanking plugs cannot be fitted to this product.
Terminals: 6 x 2.5mm2 as standard. Contact MEDC for options
Earth Continuity: Earth continuity is provided by internal plate.
Duty Labels: Burning house' label fitted as standard on red units.
Red blank duty label fitted as standard on all other colour units, unless text is supplied by customer.
Tag Label: worded to customers requirements.
Addr. module: Consult MEDC for options.
Resistors: Various configurations available, 470 Ohms minimum.
Diodes: Various configurations available.
Export Info
Made inUnited Kingdom

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
SM87_BGLAI_NNNNNNNNNR
(4192)

MEDC  SM87BGLAINNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA (Class I Groups A-D), CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,359.12 
SM87_BGLAD_NNNNNNNNNR
(1588)

MEDC  SM87BGLADNNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db. CSA (Class I Div 1), CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,458.04 
STEXCP8PBSASDN1A1R
(6461)

E2S  STEXCP8PBSASDN1A1R

E2S STExCP8-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8PMSASDL1A1R
(6462)

E2S  STEXCP8PMSASDL1A1R

E2S STExCP8-PT/M Tool Reset or Momentary Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8BGSASDN1A1R
(6460)

E2S  STEXCP8BGSASDN1A1R

E2S STExCP8-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

PH1W1B3BSNNNR
(4246)

MEDC  PH1W1B3BSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof only version. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67.