Medc Bgebnnnn100dsnnn7r | Call Points | Atex Eexed | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MEDC   BGEBNNNN100DSNNN7R

MEDC BGEBNNNN100DSNNN7R

ALARM SIGNAL DEVICES / ATEX EEXED
CALL POINTS

$615.05  [9 Weeks]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exed (Increased Safety). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2G. GOST R, CQST and Inmetro approvals also available.

BGEBNNNN100DSNNN7R   
615.05

Certification
Entry
Entry
Label
Label
Label
Voltage
Switch
Options
Options
Options
Terminals
Finish

   9 Weeks  ]
251 Variants of base SKU / 30 Shown

These manual fire alarm call points have been designed for use in hazardous locations and harsh environmental conditions. The GRP enclosures are suitable for use offshore or onshore, where lightweight combined with a high level of corrosion resistance is required.

FEATURES

  • Polyester enclosure – light, strong and not subject to corrosion.
  • 2 models:
    Breakglass.
    Pushbutton.
  • 4 basic versions available:
    (1) Explosion protected Exe (ATEX, Chinese [CQST],Brazilian [Inmetro])
    (2) Explosion protected Exi (ATEX, GOST ‘R’, GOST ‘K’, Chinese (CQST),
    Brazilian [Inmetro] or CSA),
    (3) Explosion protected: Class I, Div. 2, Groups A-D
    Class II, Div. 2, Groups F & G (PB only)
    Class I, Zone 2
    (4) Weatherproof & Dust-tight/UL ordinary locations.
  • In line and end of line resistors and/or zener diodes can be fitted.
  • Variety of colours available.
  • Up to 9 terminals available.
  • Lift flap available for extra protection against inadvertent operation.
  • Optional LED – this indicates that the unit has been operated – useful for testing purposes.
  • Earth continuity option for metal glands.
  • 1 or 2 changeover switches.
  • Captive cover screws.
  • SIL 2 Certified.
Breakglass Model
  • No hammer required – the glass is covered by a membrane thus protecting the operator from glass fragments.
  • A plastic ‘Break glass’ or deformable operating element is available to replace the break glass*.
  • Once the flexible element is pressed it bends but will not break. The unit is reset by repositioning the element. All other functions remain the same.
  • Complies with the British Standard for call points.
  • Key operated test facility – simple but secure.
  • Breakglass hammer available.

Specification
Model: BGW & PBW *BGUL & PBUL BGE & PBE BGI & PBI
Protection: Weatherproof/dust proof Explosion Protected
Class I, Div 2
Class II, Div 2
Explosion Protected Exed (Increased Safety) Explosion Protected Exia (Intrinsically Safe)
Certification: Weatherproof/dust proof
IP66/IP67
UL Listed to Class I, Div 2, Groups A-D BGUL & PBUL Class II, Div 2, Groups F & G (PBUL only) Listing No. E186629
UL listed for ordinary locations Listing No. S8117
*Refer to UL data sheet at rear of catalogue for complete information
ATEX approved Ex II 2GD BAS02ATEX2105X (PB only)
ATEX approved Ex II 2G BAS02ATEX2105X (BG only)
Exed IICT6 (switch only)
Exedm IICT4 (other versions)
CENELEC EN50014
EN50019
EN50018
EN50028
Suitable for use in Zones 1 & 2
Chinese Certification (PBE & BGE):†
CQST – Exed IIC T6 (switch only)
Exedm IIC T4 (other versions)
GOST ‘R’ Certification (PBE & BGE):
Exedm IIC T6
Exedm IIC T4 (other versions)
Russian Fire Approved
Brazilian (Inmetro) Certification:
BR-Ex emd IIC T4 or BR-Ex ed IIC T6
SIL 2 Certification to 61508.
Cert. No. Sira 11013 (BGE only).
American Bureau of Shipping Type Approval BGE only
ATEX approved Ex II 1GD Baseefa 03ATEX0084X (PB only)
ATEX approved Ex II 1G Baseefa 03ATEX0084X (BG only)
Exia IIC T4
CENELEC EN50014
CENELEC EN50020
Suitable for use in Zones 0, 1 & 2
CSA Certification to C22.2 (PBI only):
Nos.0-M, 0.4-M, 14-M, 25, 30-M, 94, 142-M1987, 157-M1987, 157-92, Enclosure Type 4. T4A
Class I Groups A, B, C & D
Cert. No. 79120
GOST ‘R’ Certification (PBI & BGI): Exia IIC T4 Russian Fire Approved
GOST ‘K’ Certification (PBI only):
Exia IIC T4
Chinese Certification (PBI & BGI):
CQST – Exia IIC T4
Brazilian (Inmetro) Certification:
BR-Ex ia IIC T4
American Bureau of Shipping Type Approval
Voltage: Up to 254V Up to 240V Up to 250V Up to 28V (IS)
Certified Temp: –40°C to +55°C
Weatherproof
–25°C to +55°C (PBUL)
–25°C to +55°C (BGUL)
UL Version
–20°C to +50°C ATEX/CENELEC –40°C to +70°C (PBI)
ATEX/CENELEC –40°C to +50°C (BGI)
CSA –50°C to +40°C (PBI only)
Switch Ratings: (1 or 2 changeover switches fitted) d.c. - 0-30v 5A (resistive) or 3A (inductive)
30-50 1A resistive or inductive
a.c. - 0-254V 5A resistive or inductive
NOT APPLICABLE

Note: UL versions Max Rating 240VAC, 3A

Specification
Material: Anti static U.V. resistant glass reinforced polyester.
Finish: Red painted finish as standard or to Customer specification.
British Standard for Call Points: BS 5839 : Part 2 : 1983 (BG).
Weight: 1.2 kg. (Varies with model & entries).
Ingress Protection: IP66 & IP67.
Entries: Up to 4 entries, M16 or M20 top and bottom (1/2" NPT available on UL version).
Terminals: 6 x 2.5mm2 – standard (BGUL only).
7 x 2.5mm2 – standard.
9 x 2.5mm2 optional – up to 60V only.
Risistors & Diodest: Various configurations available on versions up to 24V and all "IS" versions. (Minimum Resistor value 100ΩPBE/BGE, 470ΩPBI/BGI).
Earth Continuity: Internal & external earth continuity is provided via an optional earth plate.
LED Indication: A high intensity red LED can be fitted as an optional extra to indicate operation on versions up to 24V and all "IS" versions.
Labels: BG Glass label - reads either
(1) Fire Break glass – press here
(2) Break glass – press her
(3) Worded to customer requirements.
PB & BG Duty label - worded to customer requirements. Rivetted on.
PB & BG Tag label - worded to customer requirements. Screwed on.
Export Info
Made inUnited Kingdom

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
SM87_BGLAD_NNNNNNNNNR
(1588)

MEDC  SM87BGLADNNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db. CSA (Class I Div 1), CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,458.04 
STEXCP8PBSASDN1A1R
(6461)

E2S  STEXCP8PBSASDN1A1R

E2S STExCP8-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8PMSASDL1A1R
(6462)

E2S  STEXCP8PMSASDL1A1R

E2S STExCP8-PT/M Tool Reset or Momentary Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8BGSASDN1A1R
(6460)

E2S  STEXCP8BGSASDN1A1R

E2S STExCP8-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

PH1W1B3BSNNNR
(4246)

MEDC  PH1W1B3BSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof only version. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67.

Configure

$1,691.55 
PH1B1B3BSNNNR
(4244)

MEDC  PH1B1B3BSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. ATEX, Ex II 2 GD, Ex d IIC T6 Gb, Ex tb IIIC T85°C Db. IECEx version also available.

Configure

$1,879.54 
PH1UL11M3MSNNNR
(4245)

MEDC  PH1UL11M3MSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. UL Class 1, Division 1 Gas groups B, C & D or UL Class 1, Division 2. Gas groups A - D.

Configure

$1,879.54 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.