Delphian 364-455-01-365-771-11 | Sulfur Dioxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

DELPHIAN   364-455-01-365-771-11

DELPHIAN 364-455-01-365-771-11
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Delphian GazTell Fixed Point Electrochemical Gas Detector for Sulfur Dioxide (SO2) 0-20 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

364-455-01-365-771-11   
Please Email us your request for quote   

Remote Display
Alarm Relays
Communications Module
Mounting Options
Sensor Adaptors
Splash Guard

   2 Weeks  ]

Hassle free safety:
  • Simple to use and install
  • Shock & vibration resistant
  • Low power consumption
  • Checks itself every second
  • Plain English displays
  • Tough
  • Reliable
  • Affordable
  • Accurate
THE DETECTOR HEAD

The GazTell detector head for electrochemical cells can be used alone or with the optional modules.

  • The small size (5”L x 2”W) makes it inconspicuous and allows placement in tight areas.
  • User-friendly, alpha-numeric LED display with understandable instructions and prompts.
  • Automatically recognizes the sensor cell with no configuration necessary.
  • Scrolls gas type every few seconds.
  • Low maintenance and low cost of ownership. The detector head logs and will display the last time it was calibrated.
  • Connects directly to conduit eliminating the need for expensive and bulky junction boxes.
  • Smart Sensor saves operator time and money. The sensor knows the highest reading since last calibration, the number of days since last calibration, how long the detector head has been in service, the percentage of life remaining in the sensor and highest/lowest temperatures observed during operation. It checks itself and its vital functions continuously.
  • Power consumption is very low. Even at its maximum power consumption (with the display at its brightest), the detector head uses only 77mA @ 24VDC.
OPTIONAL SLAM
Remote Relay Module
  • Set alarm levels without software, using simple jumper selection.
  • The module can be placed anywhere relays are needed.
  • Flexible design allows the relays to be placed next to the functions they operate.
  • The relay module has robust relays rated at 6 amp@120 volt relays for Fail, Low and High Alarms, so auxiliary relays are often not needed. Alarm relays can be latching or non-latching, energized or de-energized, normally open or closed. A 5 second alarm delay can be turned on to avoid false alarms.
  • FM Approvals tested the SLAM module for operation at -4 oF to 140 oF (-20 oC to +60 oC).
OPTIONAL EXMO
Remote Display Module

The EXMO communicates directly with the detector head and mimics its display. If the detector head is located remotely high or low, or in a difficult-to-calibrate place, locating the EXMO in an accessible position gives immediate access to the detector head’s sensor. It displays everything the detector head displays. It gives control via bi-directional RS-485 communication.

Remote calibration has never been so easy.

The small extension module has the same alpha numeric LED displays and color coded operation as the remotely placed detector head.

  • Check the sensor before entering a dangerous area.
  • Take the sensor online or offline
  • Calibrate
  • Cancel calibration

SPECIFICATIONS
DimensionsDetector Head: 5"L x 2"W
EXMO, SLAM & COMO: (each) 6"L x 3.5"W x 2"H
Shipping Weight Detector Head: .875 lbs (.4 kg)
EXMO, SLAM & COMO: (each) 1.25 lbs (.6 kg)
Power: Detector Head: 77 mA max
EXMO: 16mA max
SLAM: 56 mA max
COMO: 35 mA max
Operating Voltage Nominally 12-42 VDC
Output Signal Range 4-20mA or 1-5 mA (user selectable, 4 - 20mA is default). Modbus RTU available as an option.
Output is linear and proportional to the gas scale.
Load (maximum resistance) 300 Ohms
Measurement Ranges ppm according to toxic gas electrochemical cell and % by volume for oxygen.
Temperature Range Cell Storage: +32 oF (0 oC) to +68 oF (+20 oC)
The detector head: (depending upon cell installed)
-20 oC (-4 oF) to +70 oC (+158 oF)
The EXMO/SLAM/COMO:
-20 oC (-4 oF) to +60 oC (+140 oF)
Pressure The operating pressure range for toxic cells is normally ambient +/-10%
Mean Time Between Failures (MTBF@70F) 8 years (electronics)
SLAM Relays 6 amps@120 volts
SLAM Response Time Less than a second from the time the detector head sees sufficient gas to trigger an alarm to the relay operating.
EXMO Response Time Less than a second from the time the detector head sees gas to the EXMO displaying that gas concentration.
Detector Head RFI/EMI Immunity Less than 1% of full scale change with 5w transceiver keyed within three feet. RFI/EMI Protection complies with EN50270, EN61000-6-4, ISA/IEC 6001-4-3
Area Hazard Classification: Class I, Divisions 1 & 2, Groups C, D
SIL (Safety Integrity Level) SIL 2
Warranty Detector Head, SLAM, EXMO and COMO: two years from date of shipment.
Cell: one year from date of shipment.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> SULFUR DIOXIDE :    24 Items found.
31001AL-0-9026/010P/L0
(5789)

RC SYSTEMS  31001AL-0-9026/010P/L0

RC Systems SenSmart 3100 3 wire gas detector for Sulfur Dioxide (SO2) 0-10ppm to 0-500ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
967-555590-020
(5147)

DETCON  967-555590-020

Detcon DM-700-SO2 Electrochemical Smart Sulfur Dioxide (SO2) 0-20ppm/0-100ppm Sensor Assembly with LED display and Aluminum Junction Box. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSS1SS
(4193)

HONEYWELL  XNXUTAENNNNN-XNXXSS1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Sulfur Dioxide (SO2) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-15ppm, 0-50ppm

Configure

$2,221.73 
6100AL1-0-1026/0030P
(7014)

RC SYSTEMS  6100AL1-0-1026/0030P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Sulfur Dioxide (SO2) 0-10ppm to 0-500ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.