E2s Bexcp3a-bg-st-nf-nl-rd | Call Points | Zone 1 And Zone 2 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   BExCP3A-BG-ST-NF-NL-RD

E2S BExCP3A-BG-ST-NF-NL-RD
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S BExCP3A-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3A-BG-ST-NF-NL-RD   
Please Email us your request for quote   

Lift flap
Duty Label
Color
Metric Adaptor

   2 Weeks  ]
30 Variants of base SKU

The BExCP3A-BG and BExCP3B-BG break glass manual call points are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. Available with and without monitoring resistors all versions are certified to ATEX and IECEx standards.

The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.

Options:
  • Alternative housing colours are available to meet specific requirements.
  • DIN rail mounted terminal blocks: 8 x 2 .5mm2
  • Stainless Steel lift flap
  • Metalised Polyester “Duty” label.
  • Series and/or End of Line resistors.
Approvals:

  • ATEX certificate: Sira 09ATEX32 86X, IEC 60079-0:2 007 Ed 5, EN 60079-1:2 004, EN 60079-7:2 007, IEC 60079-18:2 009 Ed 3, EN 612 41-1:2 004
  • IECEx certificate: IECEx SIR 09.012 1X, IEC 60079-0:2 007-10 Edition: 5, IEC 60079-1:2 003 Edition: 5, IEC 60079-18:2 009 Edition: 3, IEC 60079-7:2 006-07 Edition: 4, IEC 612 41-1:2 004 Edition: 1
  • Inmetro certificate: 10-IEx-0011X
  • GOST-R certificate: PO CC G B.JB05.B03365
  • Complies with design requirements of EN54-11

Specification
BExCP3A-BG : II 2 G Ex e d IIC T6 G b
II 2 D Ex t IIIC T60°C Db
IP66
Ambient: Ta = -40°C to +55°C [-40°to +131°F]
Ingress protection: IP66
Housing material: Marine grade copper free LM6 Aluminium
Housing finish: Phosphated & powder coated finish: anti-corrosion.
Colour: RAL3000 Red (others available on request)
Cable entries: 2 x M20 clearance top and 1 x M20 clearance side. Back box can be rotated to give 2 x bottom and 1 x side entries.
Stopping plugs: 2 x Ex enylon plugs as standard Brass and stainless steel plugs optional
Terminals: 6 x 4.0mm2 cables or or 8 x 2 .5mm2 DIN rail
Weight: 0.8Kg
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)8531909000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
BExCP3A-PT-ST-NL-RD
(4085)

E2S  BExCP3A-PT-ST-NL-RD

E2S BExCP3A-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BGWNNNNN100DSNNN7R
(4159)

MEDC  BGWNNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Weatherproof and dust proof only (Uncertified). IP66 & IP67. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$477.46 
BGIBNNNN100DSNNN7R
(4157)

MEDC  BGIBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exia (Intrinsically Safe). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD. GOST R, CQST and Inmetro approvals also available.

Configure

$494.64 
GNEXCP6A-PB-SNNRD
(4087)

E2S  GNEXCP6A-PB-SNNRD

E2S GNExCP6A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6A-PT-SNNRD
(4088)

E2S  GNEXCP6A-PT-SNNRD

E2S GNExCP6A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-PB-SNSNRD06
(6444)

E2S  GNEXCP6B-PB-SNSNRD06

E2S GNExCP6B-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6B-PT-SNSNRD06
(6445)

E2S  GNEXCP6B-PT-SNSNRD06

E2S GNExCP6B-PT Tool Reset Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

PBUWNNNN0DSNNN7R
(4212)

MEDC  PBUWNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof only version. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$541.92 
PBIBNNNN0DSNNN7R
(4209)

MEDC  PBIBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD, Ex ia IIC T4 Ga, Ex ia IIIC T135C Da. CUTR, Inmetro and CQST certifications also available.

Configure

$559.15 
BGEBNNNN100DSNNN7R
(1573)

MEDC  BGEBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exed (Increased Safety). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2G. GOST R, CQST and Inmetro approvals also available.

Configure

$615.05 
BGULNNNN100DSNNN6R
(4158)

MEDC  BGULNNNN100DSNNN6R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected. Designed for use in hazardous locations and harsh environmental conditions. NEMA 4X and 6. UL approved for Class I, Div 2 and Class II, Div 2 Groups A, B, C and D. Weatherproof only version (for Ordinary Locations) also available.

Configure

$670.91 
PBULNNNN0DSNNN7R
(4211)

MEDC  PBULNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. UL Listed for Class 1, Div 2, Groups A,B,C,D, Class II, Div 2, Groups F & G.

Configure

$679.51 
PBICNNNN0DSNNF7R
(4210)

MEDC  PBICNNNN0DSNNF7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. CSA Certified, Class 1, Groups A,B,C,D

Configure

$683.83 
PBEBNNNN0DSNNN7R
(1574)

MEDC  PBEBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2GD. EExed IIC T6 (T4 if resistors fitted). CUTR, Inmetro and CQST certifications also available.

Configure

$692.54 
D1XCP1PSDXSNNRD
(6407)

E2S  D1XCP1PSDXSNNRD

E2S D1xCP1-PS Explosion Proof Manual Alarm Pull Station for use in harsh operating environments and hazardous locations. NEMA 4X cast aluminium housing. DPDT switch. UL and FM listed.



 
XAL-53
(6225)

NOTIFIER  XAL-53

Notifier XAL-53 Explosion Proof / Weather Proof Pull Station with Ring. Copper Free Aluminum Enclosure and 3/4" NPT conduits. Suitable for Class I Div 1, Class II Div 1 & 2 and Class III on Hazardous Locations. NEMA 7. UL and CSA Approvals.



 
SM87PBLAI_NNNNNNNNNR
(4219)

MEDC  SM87PBLAINNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,230.09 
SM87PBLAULNNNNNNN_N_N_R
(4220)

MEDC  SM87PBLAULNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Push Button Latching Key Reset version. Designed for the most harduous environmental conditions. UL Listed: Class 1, Div 1 Groups C & D. UCL version also available.

Configure

$1,294.65 
SM87PBLAD_NNNNNNNNNR
(1575)

MEDC  SM87PBLADNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,346.25 
SM87_BGLAI_NNNNNNNNNR
(4192)

MEDC  SM87BGLAINNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA (Class I Groups A-D), CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,359.12 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.