Honeywell 2106b1420 | Sulfur Dioxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   2106B1420

HONEYWELL 2106B1420
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Sieger Sensepoint Gas Detector Transmitter for Sulfur Dioxide (SO2) (0-15 to 0-50 ppm) ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

2106B1420   
1,135.98

Certification/Entry Size
Gas Range
Weather housing
Terminal Housing
Bartec DE1155 With Continuity Plate 1 X 25mm - 3 X 20mm Entries -ATEX Approved

   4 Weeks  ]
6 Variants of base SKU

The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation in potentially explosive atmospheres is made by the use of a suitable Ex d or Ex e approved junction box. The industry standard outputs from Sensepoint are connected to either a choice of Honeywell Analytics’ controllers or 3rd party DCS/ PLC systems. Both flammable and toxic versions are certified to the latest ATEX/ IECEx safety and performance standards.

The flammable detector is available in either % LEL or PPM detection range versions and provides an industry standard mV bridge output. Typical life expectancy is greater than 5 years, after which the detector is simply replaced with a new one.

The toxic detectors are supplied pre calibrated for easy installation and provide an industry standard 2 wire 4-20mA loop output. User connections are Ex d, while front end Intrinsic Safety (IS) design allows for easy exchange of the replaceable sensor while powered. IS design also removes the need for a sinter enabling very fast speed of response and detection of ‘sticky’ gases such as Chlorine and Ammonia.

Sensepoint has proven its suitability across a wide range of demanding applications by delivering high performance and reliability at an affordable cost.

Fit For Purpose
  • Flammable, toxic and Oxygen versions available
  • High performance, low cost
  • Suitable for new and retro fit applications
Proven Sensor Technology
  • SurecellTM electrochemical sensors
  • Poison resistant catalytic bead
  • Fast and reliable
  • Typical 2 to 5 years operational life
ATEX/IECEx Certified
  • Complies with the latest standards
  • Hazardous area approval and performance
  • IP65/67 for use in harsh environments
  • Easy to Use
  • Factory set operation
  • Simple to replace
  • Minimal training required
Range of Accessories
  • Weatherproof cap
  • Flow adaptor
  • Duct mounting kit
  • Collecting cone

Installation Details

Dimensions

Sensepoint Dimensions

Sensepoint flammable and toxic gas detectors are installed using suitable Ex d or Ex e junction boxes. The standard junction box available from Honeywell Analytics includes an earth continuity plate for added RFI protection. The detectors have a choice of mounting thread size to match local preferences.

The Sensepoint range of flammable and toxic detectors are designed for use with a wide range of controllers available from Honeywell Analytics or with 3rd party control equipment accepting their industry standard output signals.

Electrical Connections

Sensepoint Electrical Connections

Sulfur Dioxide (SO2) 15/50ppm
Operating Temp -15 to +40˚C
Operating HumidityContinuous: 20 to 90% RH (non-condensing). Intermittent: 10 to 99% RH (non-condensing)
Storage Conditions0 to 25˚C; 30 to 70% RH
Operating Pressure90 to 110kPa
Warm-up Time < 3 minutes
Response Time
T20 -
T50 < 10 secs
T90 < 90 secs
Supply18 to 30VDC; 0.9W maximum
Signal OutputLoop powered 4-20mA
Linearity< 5% fsd
Operating Life18 months (typical)
Storage Life6 months.
Stability (zero)
with time* < ±2% fsd / yr
with temperature** < ±5% fsd
with humidity < ±10% fsd
Stability (span)
with time* < ±2% fsd / yr
with temperature*** < ±15% fsd
with humidity < ±10% fsd
Weight185g
Construc. MaterialsPolyphenylene Sulphide (PPS)
I.P. (NEMA) RatingIP65 (standard), IP67 (with weather protection fitted)
Certification Details
(ATEX/ IECEx)
II 2 GD Ex d ia IIC T4 Gb Tamb -40ºC to +65ºC
tb IIIC A21 IP67 T135ºC Db
Baseefa08ATEX0263X
IECEx BAS08.0070X
Other CertificationsRussian: GOST
Applicable StandardsThis product complies with the relevant CE standards including: EMC to EN50270, Flammable sensor to EN60079-29-1

* = % of range (fsd) per year
** Over operating temperature range
*** = % of applied concentration

Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
02000-A-1635
(1470)

HONEYWELL  02000-A-1635

Honeywell Weather Protection Housing with calibration port / calibration cup for XNX MPD sensors



$110.94 
CYL-90301522
(4097)

PORTAGAS  CYL-90301522

Calibration Gas Sulfur Dioxide (SO2) 25 ppm Balance Nitrogen, 34 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$113.24 
BW-CG2S5058-EQUIV
(2189)

PORTAGAS  BW-CG2S5058-EQUIV

Calibration Gas Sulfur Dioxide 50ppm Balance Nitrogen Size 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas)

Configure

$171.58 
CYL-10631030
(1309)

PORTAGAS  CYL-10631030

Calibration Gas Sulfur Dioxide (SO2) 20 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$171.58 
00780-A-0100
(1560)

HONEYWELL  00780-A-0100

Sensepoint Terminal Housing - Bartec DE1155 With Continuity Plate 1 X 25mm - 3 X 20mm Entries -ATEX Approved



$181.44 
CYL-10629000
(1308)

PORTAGAS  CYL-10629000

Calibration Gas Sulfur Dioxide (SO2) 5 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$206.64 
> SULFUR DIOXIDE :    24 Items found.
31001AL-0-9026/010P/L0
(5789)

RC SYSTEMS  31001AL-0-9026/010P/L0

RC Systems SenSmart 3100 3 wire gas detector for Sulfur Dioxide (SO2) 0-10ppm to 0-500ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
967-555590-020
(5147)

DETCON  967-555590-020

Detcon DM-700-SO2 Electrochemical Smart Sulfur Dioxide (SO2) 0-20ppm/0-100ppm Sensor Assembly with LED display and Aluminum Junction Box. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSS1SS
(4193)

HONEYWELL  XNXUTAENNNNN-XNXXSS1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Sulfur Dioxide (SO2) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-15ppm, 0-50ppm

Configure

$2,221.73 
6100AL1-0-1026/0030P
(7014)

RC SYSTEMS  6100AL1-0-1026/0030P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Sulfur Dioxide (SO2) 0-10ppm to 0-500ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.