Gds Gm/ec-03-13-01 | Chlorine Dioxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GM/EC-03-13-01

GDS GM/EC-03-13-01
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GASMAX/EC 2-Wire Gas Detector with backlit LCD display and local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (CLO2) with range 0-1 ppm, 4-20 mA output transmitter.

Inquiry



The GASMAX EC single channel gas monitor for toxic or oxygen deficiency ap- plications delivers the latest in loop-pow- ered gas detection technology, reliability and ease of use.

Wide Variety of Available Sensors

The GASMAX EC support all GDS Corp toxic sensors, including oxygen, hydrogen sulfide, chlorine, carbon monoxide and more. In addition, GDS Corp Smart Sen- sors enhance this capability by maintain- ing their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX EC constantly tracks sensor performance and calculates an estimate of sensor life remaining. Built-in fault detection circuity constantly monitors the sensor for correct operation.

Advanced User Interface

The highly visible graphic display and flashing alarm LEDs constantly show alarm status, calibrated engineering values and a programmable tag name, plus a trend screen shows alarm levels and a graph of the most recent 30 minutes.

An internal real-time clock and event log time-stamp up to 300 calibration and alarm events for later review. Taking advantage of the high-resolution graphic display, an easy-to-use menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Three operational levels of security al- low the GASMAX EC to be fully field configurable, partially restricted or com- pletely restricted by way of user ID and access code.

Explosion-Proof or Intrinsically Safe

The GASMAX EC is CSA certified for use in Div 1 & Div 2 hazardous areas and can be installed as Explosion Proof (with stainless steel sensor head) or Intrinsi- cally Safe (with aluminum sensor head) using appropriate wiring techniques and an Intrinsically Safe barrier. See notes on IS installation on back. An ATEX certi- fied version for XP installations is also available.

FEATURES

  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Non-polarized loop powered inter- face eliminates wiring errors
  • Graphic display shows values, units, trend graph, alarm levels
  • Three flashing Alarm LEDs with Programmable Alarm Levels
  • Real time clock tags alarm and calibration events
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibra- tion with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • For combustible applications, see the GASMAX II gas monitor

Note: Sensor Heads 3, 4 and 8 require INTRINSICALLY SAFE (IS) installations in hazardous locations. IS installations require an IS barrier (#10-0263 MTL 7787P+) or equivalent that must be mounted in an area designated as Non-hazardous.

GASMAX EC SPECIFICATIONS
Power Input: 10-30VDC at less than 0.75 watts in 2-wire 4-20mA configuration
Display 64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units display.
Input Accepts microamp-level signals from local or remote GDS Corp toxic or oxygen deficiency sensors
Calibration Range Zero = +/- 15% of range with 0.1% resolution
Span = Gain adjustment of 0.5 to 2.0 with 0.1% resolution
Accuracy +/- 5% of full scale range (typical)
Standard Output Standard 2-wire 4-20mA current sink output. Max loop R is 600 ohms with nominal 24VDC power supply.
Temp -25°C to +60°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel optional
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified Div 1 & 2 Groups B, C, D. Suitable for explosion-proof installations
CSA Certified Div 1 & 2 Groups A, B, C, D. Intrinsically safe.
IMPORTANT: Intrinsically Safe installations require IS barrier #10-0263 (MTL 7787P+) or equivalent.
ATEX Certified EX II 2 G EEx d IIB + H2 T5
Warranty Two years on electronics and one year on sensors from date of purchase
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    4 Items found.
10-0203
(259)

GDS  10-0203

GDS Sensor calibration cup for stainless steel / aluminum sensor heads



 
(261)

GDS  10-0263

GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent



 
10-9513-R01
(326)

GDS  10-9513-R01

Electrochemical Smart Sensor configured for Chlorine Dioxide (ClO2) with range 0-1 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-49, GDS-58XP.



 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
> CHLORINE DIOXIDE :    7 Items found.
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.