Firelite Bg-12 | Call Points | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

FIRELITE   BG-12

SKU# (7719)



FIRELITE BG-12
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Fire-Lite Alarms BG-12 Manual Fire Alarm Single or Dual action Pull Station for Fire-Lite Alarm Control Panels (FACPs). Includes SPST N/O switch. Polycarbonate housing. UL, FM, CSFM and MEA Approvals. Replaces BG-10.

UL   FM

BG-12   
Please Email us your request for quote   

Model

   In Stock  ]

The Fire-Lite BG-12 Series is a cost-effective, feature-packed series of non-coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of models including single- and dual-action versions.

The BG-12 Series provides Fire-Lite Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the BG-12 Series simple to install, maintain, and operate.

Features
  • Aesthetically pleasing, highly visible design and color.
  • Attractive contoured shape and light textured finish.
  • Meets ADA 5 lb. maximum pull-force.
  • Meets UL 38, Standard for Manually Actuated Signaling Boxes.
  • Easily operated (single- or dual-action), yet designed to prevent false alarms when bumped, shaken, or jarred.
  • PUSH IN/PULL DOWN handle latches in the down position to clearly indicate the station has been operated.
  • The word "ACTIVATED" appears on top of the handle in bright yellow, further indicating operation of the station.
  • Operation handle features white arrows showing basic operation direction for non-English-speaking persons.
  • Braille text included on finger-hold area of operation handle and across top of handle.
  • Multiple hex- and key-lock models available.
  • U.S. patented hex-lock needs only a quarter-turn to lock/unlock.
  • Station can be opened for inspection and maintenance without initiating an alarm.
  • Product ID label viewable by simply opening the cover; label is made of a durable long-life material.
  • The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside).
  • Four-position terminal strip molded into backplate.
  • Terminal strip includes Phillips combination-head captive 8/32 screws for easy connection to Initiating Device Circuit (IDC).
  • Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.1 mm²).
  • Terminal numbers are molded into the backplate, eliminating the need for labels.
  • Switch contacts are normally open.
  • Can be surface-mounted (with SB-10 or SB-I/O) or semi-flush mounted. Semi-flush mount to a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box.
  • Backplate is large enough to overlap a single-gang backbox cutout by 1/2" (1.27 cm).
  • Optional trim ring (BG12TR).
  • Spanish versions (FUEGO) available (BG-12LSP, BG-12LPSP).
  • Designed to replace the Fire-Lite legacy BG-10 Series.
  • Models packaged in attractive, clear plastic (PVC), clamshell-style, Point-of-Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station.
Construction

Cover, backplate and operation handle are all molded of durable polycarbonate material. Cover features white lettering and trim. Red color matches System Sensor's popular SpectrAlert® Advance horn/strobe series.

Operation

The BG-12 manual pull stations provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking people.

Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key, twist one quarter-turn, then open the station's front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch.

Agency Listings and Approvals

The listings and approvals below apply to the BG-12 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • C(UL)US: S711
  • FM Approved
  • CSFM: 7150-0075:184
  • MEA: 67-02-E
  • Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108.

PHYSICAL SPECIFICATIONS
Pull Station Height 5.5 inches (13.97 cm)
Pull Station Width 4.121 inches (10.47 cm)
Pull Station Depth 1.39 inches (3.53 cm)
SB-I/O Height 5.601 inches (14.23 cm)
SB-I/O Width 4.222 inches (10.72 cm)
SB-I/O Depth 1.439 inches (3.66 cm)
SB-10 Height 5.5 inches (13.97 cm)
SB-10 Width 4.121 inches (10.47 cm)
SB-10 Depth 1.375 inches (3.49 cm)
ELECTRICAL SPECIFICATIONS
Switch Contact Ratings Gold-plated; rating 0.25 A @ 30 VAC or VDC
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)85318

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping & Handling

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    54 Items found.
PBICNNNN0DSNNF7R
(4210)

MEDC  PBICNNNN0DSNNF7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. CSA Certified, Class I, Groups A,B,C,D

Configure

$861.04 
PBEBNNNN0DSNNN7R
(1574)

MEDC  PBEBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2GD. EExed IIC T6 (T4 if resistors fitted). CUTR and CQST certifications ... more

Configure

$872.01 
XAL-53
(6225)

NOTIFIER  XAL-53

Notifier XAL-53 Explosion Proof / Weather Proof Pull Station with Ring. Copper Free Aluminum Enclosure and 3/4" NPT conduits. Suitable for Class I Div 1, Class II Div 1 & 2 and Class III on Hazardous Locations. NEMA 7. UL ... more



 
STEXCP8PBSASDN1A1R
(6461)

E2S  STEXCP8PBSASDN1A1R

E2S STExCP8-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and ... more

STEXCP8PMSASDL1A1R
(6462)

E2S  STEXCP8PMSASDL1A1R

E2S STExCP8-PT/M Tool Reset or Momentary Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, ... more

SM87PBLAI_NNNNNNNNNR
(4219)

MEDC  SM87PBLAINNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,548.84 
STEXCP8BGSASDN1A1R
(6460)

E2S  STEXCP8BGSASDN1A1R

E2S STExCP8-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and ... more

SM87PBLAULNNNNNNN_N_N_R
(4220)

MEDC  SM87PBLAULNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Push Button Latching Key Reset version. Designed for the most harduous environmental conditions. UL Listed: Class I, Div 1 Groups C & D. UCL version also available.

Configure

$1,630.16 
SM87PBLAD_NNNNNNNNNR
(1575)

MEDC  SM87PBLADNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85 DegreesC/T100 DegreesC Db. CSA, CUTR, IECEx and Inmetro versions ... more

Configure

$1,695.13 
SM87_BGLAI_NNNNNNNNNR
(4192)

MEDC  SM87BGLAINNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA (Class I Groups A-D), CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,711.34 
SM87_BGLAD_NNNNNNNNNR
(1588)

MEDC  SM87BGLADNNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex d IIC T5/T6 Gb, Ex tb IIIC T85 DegreesC/T100 DegreesC Db. CSA (Class I Div 1), CUTR, IECEx, Inmetro and CQST versions also ... more

Configure

$1,835.88 
PH1W1B3BSNNNR
(4246)

MEDC  PH1W1B3BSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof only version. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67.

Configure

$2,129.91 
PH1B1B3BSNNNR
(4244)

MEDC  PH1B1B3BSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. ATEX, Ex II 2 GD, Ex d IIC T6 Gb, Ex tb IIIC T85 DegreesC Db. ... more

Configure

$2,366.61 
PH1UL11M3MSNNNR
(4245)

MEDC  PH1UL11M3MSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. UL Class I, Div 1 Gas groups B, C & D or UL Class I, Div ... more

Configure

$2,366.61 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.