XTRALIS   VLF-500-00-UL

SKU# (7662)
XTRALIS VLF-500-00-UL

DETECTORS / SMOKE
ULTRASONIC

$1,369.80  [In Stock]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Xtralis VESDA VLF-500 smoke detector with Ultrasonic Flow Sensing. Includes 3 changeover relays. 18-30 VDC. Suitable for Class 1 Div 2. CCC, FM, VdS, CE and UL approvals. IP30. For environments of less than 500 m2.

RELAYS   UL   FM   DIV 2

VLF-500-00-UL
$1,369.80      

   In Stock  ]

The VESDA VLF-500 detector is a very early warning smoke detector designed to protect small, business-critical environments of less than 500 m2 (5,380 sq. ft.).

The detector works by continually drawing air into sampling holes in a pipe network. The air is filtered and passed into a detection chamber where light scattering technology detects the presence of very small amounts of smoke. Detector status information is communicated on the detector display and via relays or optional interface cards.

Out-of-the-Box Operation

The VLF can be installed and commissioned out-of-the-box without the need for a special interface or software programming tools.

Ultrasonic Flow Sensing

The patented Ultrasonic Flow Sensing used in the VLF provides a direct reading of the sampling pipe flow rate. The system is immune to air temperature and pressure changes and is unaffected by contamination. The VLF is the first air sampling smoke detector to use ultrasonic flow sensing.

Features
  • Out-of-the-Box Installation and Commissioning
  • Ultrasonic Airflow Sensing
  • Laser-Based Absolute Smoke Detection
  • Pre-engineered pipe network designs
  • Programmable Alarm Thresholds
  • Clean air barrier optics protection
  • Instant Recognition Display
  • Instant Fault Finder™
  • AutoLearn™ Smoke
  • AutoLearn™ Flow
  • Field Service Access Door
  • Multiple Event Logging in separate logs
  • Event log – up to 18000 events
  • Offline/online configuration capability
  • Up to 500 m2 (5,380 sq. ft.) coverage
Listings / Approvals
  • CCC
  • FM Class I Div II
  • ActiveFire (ISO/AS 7240-20)
  • CE
  • UKCA
  • LPCB
  • VdS
  • NF
  • EN 54-20
    -Class A (30 holes / 0.05% obs/m)
    -Class B (30 holes / 0.15% obs/m)
    -Class C (30 holes / 0.32% obs/m)

Specifications
Input Power Voltage: 24V DC Nominal (18-30 V DC)
410 mA nominal, 490 mA in alarm
Dimensions (W x H x D) 256 mm x 183 mm x 92 mm (101/16 in x 71/5 in x 32/3 in)
Weight Approx. 2 kg (4.4 lbs)
Mounting Upright, inverted or horizontal
IP rating IP30
Operating Conditions* Ambient: 0°C to 38°C (32°F to 100°F)
Sampled Air: -20°C to 60°C (-4°F to 140°F) *
Humidity: 5% to 95% RH, non-condensing
*Sampled Air temperature shall reach Ambient Detector temperature upon entry into Detector. Refer to Xtralis Design Guides & Application Notes for sampled air pre-conditioning.
Sampling Network Maximum pipe lengths: 1 x 50 m (150 ft) (Max. 24 holes) 2 x 30 m (90 ft) per branch (Max. 12 holes per branch)
Sampling Hole Options: Pre-Engineered Option or Maximum Pipe length in accordance with Pipe Modelling Design Tool (ASPIRE™)
Air Inlet Pipe Accepts both metric and American standard pipe sizes
Metric: 25 mm (1.05 in.) American Pipe: IPS 21 mm (¾ in.)
Area Coverage Up to 500 m2 (5,380 sq. ft.) depending on local codes and standards
Relay Outputs 3 changeover relays (Fire 1, Action, Fault), Contacts rated 2A @ 30 VDC (max). NO/NC Contacts
Cable access 3 x 25 mm (11/16 in.) cable entries (1 rear entry, 2 top entry)
Cable termination Screw Terminals 0.2-2.5 mm (30-12 AWG)
Interfaces Shown in Terminal Block Connections diagram, to right, plus an RS232 Programming Port. General Purpose Input (GPI) interface offers: Reset, Disable, Standby, Alarm set 1, Alarm set 2 and External Input functions.
Alarm Threshold Setting Range Alert, Action: 0.025 - 2.00% obs/m (0.008 - 0.614% obs/ft)
Fire 1, Fire 2: 0.025 - 20.00% obs/m (0.008 - 6.575% obs/ft)
Individual Alarm Delays: 0 – 60 seconds
Two Alarm Threshold Settings: Either time or GPI based
Display 4 Alarm State Indicators
Smoke Level Indicator
Reset, Disable and Test Control
Fault and Disabled Indicators
Instant Fault Finder
Smoke and Flow AutoLearn Controlss
Event Log Up to 18000 events, time and date stamped in separate, non-volatile, logs for: Smoke Level, Flow Level, Detector Status and Faults
AutoLearn Smoke & Flow Automatically set acceptable alarm thresholds for both smoke and flow levels
Minimum 15 minutes, maximum 15 days (default 14 days)
During AutoLearn thresholds are NOT changed from pre-set values

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping & Handling

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ULTRASONIC :    1 Items found.
ATX10S5M26T-AC100SMT2
(7428)

DET-TRONICS  ATX10S5M26T-AC100SMT2

Det-tronics FlexSonic Acoustic Gas Detector with AC100 Sensor with DSP technology and ATX10 Transmitter. 24 discrete ultrasonic bands. M25 threads. 4-20 mA output combined with HART. 24 VDC. IP66, NEMA 4X. SIL, FM, CSA, ATEX and IECEx approvals.



 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.