Simplex Tyco 2099-9139 | Call Points | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

SIMPLEX TYCO   2099-9139

SKU# (7524)
SIMPLEX TYCO 2099-9139
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Simplex Tyco 2099-9139 Dual Action Non Coded Manual Station with PUSH Lever. SPST. Normally open contact. Cast Metal. UL Listed and CSFM approval.

UL

Please Email us your request for quote   

   In Stock  ]
Features

Common mechanical and electrical features:

  • Rugged cast metal construction
  • Terminal connections for In/Out Wiring
  • Visible break rod provides status indicator; optional, not required for operation
  • Standard operation station will mount semi-flush on a single gang box, 2 1/2 in. deep
  • Operation is compliant with ADA requirements
  • Listed to UL Standard 38
Description

Cast metal construction: For applications requiring cast metal construction, these non-coded manual stations provide a variety of models and operations. Single action stations are operated by pulling the handle. Dual action stations require that you push the top "PUSH" lever to grab the "PULL" lever.

Indication and reset: When pulled, the alarm condition is mechanically latched and indicated by the extended handle. You can reset by unlocking and opening the enclosure. A Simplex ® “B” key controls the lock, provided with each station.

Break rods: Stations include an optional replacement break rod. Break rod status is visible from the front of the station. The use of a break rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for activation.

Optional surface mount boxes match the contours of the stations and provide an attractive appearance. Model 2099-9144 includes both station and enclosure. Use of the 2975-9211 weatherproof box provides a NEMA 3R rating. NEMA 3R enclosures are for outdoor use, primarily for protection against rain and sleet, and ice formation on the exterior.

Specifications
Contact ratings (resistive) UL, C-UL, & CSFM = 1 A @ 30 VDC or 125 VAC; FM = 1 A @ 30 VAC/VDC
Operation with 2975-9211 box Temperature range = -40°F to 150°F (-40°C to 66°C); suitable for outdoor applications; NEMA 3R rated
Operation with 2975-9212 box Temperature range = 32°F to 140°F (0°C to 60°C); intended for indoor applications Humidity range = up to 90% RH at 90°F (32°C)
Wiring connections Terminal blocks for IN/OUT wiring, up to 14 AWG (2.08 mm )
Housing and handles Cast zinc; both PUSH and PULL handles
Colors Red housings with white levers and white raised lettering
Additional information Refer to Installation Instructions supplied with product
Export Info
Harmonized Tariff Code (HTC)85311001

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    52 Items found.
NOT-BG-12LX
(7237)

NOTIFIER  NOT-BG-12LX

Notifier NOT-BG12LX Addressable Manual Pull Station, dual-action (requires two motions to activate the station). Surface or Semi-flush mounting. 24a VDC. UL, FM, CSFM and MEA Approved.



 
4099-9006
(7504)

SIMPLEX TYCO  4099-9006

Simplex Tyco 4099-9006 addressable manual fire alarm station. Double Action, Push operation. IDNet or MAPNET II addressable communications. NEMA 1 rated. UL listed and FM Approved.



 
NBG-12
(6824)

NOTIFIER  NBG-12

NOTIFIER by Honeywell NBG-12 Non-Coded Conventional Manual Fire Alarm Pull Station that initiates an input signal for any conventional control panel (FACP). Single or Dual Action Versions. UL, CSFM and FM Approvals.

2099-9754
(6850)

SIMPLEX TYCO  2099-9754

Simplex Tyco 2099-9XXX non-coded non-addressable manual station. Single or Double action operation. Surface or Flush mounting. High impact polycarbonate housing. Complies with ADA requirements. UL listed.

NBG-12LR
(5811)

NOTIFIER  NBG-12LR

Notifier NBG-12LR Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual-action agent release station. FM Approved and cUL Listed.

4099-9004
(6848)

SIMPLEX TYCO  4099-9004

Simplex Tyco 4099-9004 addressable manual station with communication module for IDNet or MAPNET II. LED indicator. Breakglass or push operation. Surface or Flush mounting. NEMA 1. Complies with ADA requirements. UL listed.

NBG-12LX
(2042)

NOTIFIER  NBG-12LX

NOTIFIER by Honeywell NBG-12LX Addressable Manual Pull Station, dual-action (requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel.

NBG-12LOB
(4603)

NOTIFIER  NBG-12LOB

Notifier NBG-12LOB Pull Station which provides a Fire Alarm Control Panel (FACP) with a single alarm input signal. Includes dual action operation, Key-Lock Reset function, outdoor-use gasket and sealed switch. UL Listed.



 
NBG-12LRA
(4142)

NOTIFIER  NBG-12LRA

Notifier NBG-12LRA Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual action operation. Abort switch. Power-on and released indication. FM Approved and cUL Listed.

IS-CP4A-BG-ST-NF-NL-RD
(4080)

E2S  IS-CP4A-BG-ST-NF-NL-RD

E2S IS-CP4A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

BG3W1NNN_BR
(1587)

MEDC  BG3W1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. Weatherproof. IP66 and IP67.

Configure

$203.35 
IS-CP4A-PT-ST-NL-RD
(4082)

E2S  IS-CP4A-PT-ST-NL-RD

E2S IS-CP4A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PB-ST-NL-RD
(4081)

E2S  IS-CP4A-PB-ST-NL-RD

E2S IS-CP4A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

BExCP3B-BG-ST-NF-NL-RD-06
(5136)

E2S  BExCP3B-BG-ST-NF-NL-RD-06

E2S BExCP3B-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3A-BG-ST-NF-NL-RD
(4083)

E2S  BExCP3A-BG-ST-NF-NL-RD

E2S BExCP3A-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

GNEXCP6A-BG-SNNNRD
(4086)

E2S  GNEXCP6A-BG-SNNNRD

E2S GNExCP6A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-BG-SNSNNRD06
(6443)

E2S  GNEXCP6B-BG-SNSNNRD06

E2S GNExCP6B-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

BG2WNN1_NR
(1586)

MEDC  BG2WNN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. Weatherproof. IP66 and IP67.

Configure

$340.47 
BG3I1NNN_BR
(4152)

MEDC  BG3I1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. ATEX approved Ex II 1G. IP66 and IP67.

Configure

$345.18 
BG2EDC1_NR
(4150)

MEDC  BG2EDC1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. DC or AC Version. EExed IIC T6 (T4 if resistors or diode fitted) ATEX Approved Ex II 2G. IP66 and IP67.

Configure

$378.25 
Page: 1 | 2 | 3 | All
Cookie Notice