Simplex Tyco 49vo-wrfo | Horns | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

SIMPLEX TYCO   49VO-WRFO

SKU# (7496)
SIMPLEX TYCO 49VO-WRFO

ALARM SIGNAL DEVICES / INDOOR
HORNS

  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Simplex Tyco 49VO-WRFO weatherproof TrueAlert ES addressable Strobe (requires weatherproof box). “FIRE” Lettering. 15 cd or 75 cd. UL listed.

UL

Please Email us your request for quote   

   In Stock  ]
Features

Individually addressed and controlled multi-candela TrueAlert ES weatherproof notification appliances for extended temperature and humidity range provide:

  • Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 75, WP 75, or WP 185 cd
  • Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup
  • Wiring supervision to each appliance allowing “T-tapped” connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring)
  • Self-Test Mode allows on-board sensors to detect the strobe and horn output and then report their status to the control panel
  • TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 3)
  • Magnet Test diagnostics to assist checkout and testing of appliances and wiring
  • Electrical test point access without removing cover
LED Indicator and Magnet Test feature:
  • Appliance LED can be selected to display each polling cycle to indicate appliance supervision
  • When the controller is in diagnostic mode, the Magnet Test pulses the LED to indicate appliance address and can be set to also briefly flash the strobe and sound the A/V horn
Mechanical design features include:
  • Rugged, high impact, flame retardant thermoplastic housing in red with white letters or white with red letters, with clear lens
  • Standard models are available with FIRE lettering or blank; configured models are available with additional lettering of FEU, FEU/FIRE, ALERT, and blank
  • Mounting is to matching weatherproof boxes (required), ordered separately
  • Separate covers are available to change application type on-site or for replacement
  • In/out wiring terminals for 18 AWG to 12 AWG
  • Enclosure is rated NEMA 3R
  • Convenient wiring terminal access at front of housing
Agency listings reference:
  • UL 1638 listed for outdoor applications with strobe rated at 75 cd (WP75) or 185 cd (WP185)
  • UL 1971 listed for indoor applications with strobe intensity selectable as 15 or 75 cd; indoor applications are compatible with ADA requirements (refer to important mounting information on page 3)
  • Horn operation is listed to UL Standard 464
  • Refer to data sheet S49WP-0002 for ULC listed models
Description

TrueAlert ES weatherproof addressable appliances provide visible and audible/visible notification for indoor and outdoor, extended temperature and extended humidity applications. They are individually addressed and receive power, supervision, and control signals from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 4.)

Strobe Application Reference

Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA).

Specifications
Typical Operating Voltage Range 23 VDC to 31 VDC, Special Application
Supervisory Requirements 1 unit load (= 0.8 mA control panel current)
IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads
Temperature Range UL 1971 Listed Rating: 32° to 120° F (0° to 49° C); 15 or 75 cd setting
UL 1638 Listed Rating: -31°F to 150°F (-35° C to 66°C); WP75 or WP185 cd setting
Humidity Range UL 1971 Listed Rating: 10% to 93%, at 100° F (38° C)
UL 1638 Listed Rating: up to 98%, at 104 °F (40° C)
IDNAC SLC Wiring Specifications UTP, unshielded twisted pair recommended
Maximum wire length allowed with “T-Taps” for Class B wiring per SLC = 10,000 ft (3048 m)
Maximum wire length to any appliance = 4000 ft (1219 m)
Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ); two wires per terminal for in/out wiring
Installation Instructions 579-1032
Export Info
Harmonized Tariff Code (HTC)85311001

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORNS :    75 Items found.
4902-9721
(7489)

SIMPLEX TYCO  4902-9721

Simplex 4902-9721 Round housing speaker with ceiling or wall mount. 25 or 70.7 VRMS. 79 to 88 dBA. NEMA 1. UL, CSFM and FM Approved.



 
BEDHEADR
(3644)

E2S  BEDHEADR

E2S BEDHEAD Alarm Sounder 90dB(A). Low current consumption. Suitable for close proximity signalling. 24VDC.

SONF1DC012_R
(3638)

E2S  SONF1DC012R

E2S SONF1 compact and high output Alarm Sounder 100dB(A). Low current consumption and high SPL. Stainless steel fixings. 12VDC, 24VDC, 24VAC, 115VAC or 230VAC Versions. IP66. VdS and GOST-R Approved. Optional UL & cULs version.

H100T030G
(3586)

E2S  H100T030G

E2S H100T signalling Horn with Trumpet 100dB(A). Compact with high output signal to generate a traditional 'buzzer' warning or two further alarm sounds. Surface Mount. Volume control and Stainless Steel fixings. 12-30VAC/DC or 40-260VAC/DC Versions. IP65. GOST-R Approved.

H100B030G
(3587)

E2S  H100B030G

E2S H100B signalling Horn 100dB(A). Compact with high output signal to generate a traditional 'buzzer' warning or two further alarm sounds. Surface Mount. Volume control and Stainless Steel fixings. 12-30VAC/DC or 40-260VAC/DC Versions. IP65. GOST-R Approved.

4906-9102
(6851)

SIMPLEX TYCO  4906-9102

Simplex Tyco 4906-91XX TrueAlarm Non-Addressable multi-candela high intensity Strobe. Ceiling-Mounted. 24VDC. 1 Hz. 15, 30, 75, or 110 candela intensity selectable. High impact flame retardant housing. NEMA 1. Complies with ADA requirements. UL listed.

SON2DC012R
(3640)

E2S  SON2DC012R

E2S SON2 compact and high output Alarm Sounder 104dB(A). Low currentconsumption and high SPL. Stainless steel fixings. 24VDC, 24VAC, 115VAC or 230VAC Versions. IP66. GOST-R Approved.

A100SONTELR
(3270)

E2S  A100SONTELR

E2S A100SONTEL compact and high output telephone initiated Alarm Sounder 100dB(A). Three alarm tone frequency (siren, alternating, sweeping). Stainless steel fixings. High impact UL94 Housing. IP66. GOST-R Approved.

A100DC_24R
(3244)

E2S  A100DC24R

E2S A100 compact and high output Alarm Sounder/Horn 104dB(A). Low current consumption and high SPL. 115VAC, 230VAC, 24V, 10-30V or 48V Versions. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

A105NSONTELR
(3272)

E2S  A105NSONTELR

E2S A105NSONTEL compact and high output telephone initiated Alarm Sounder 105dB(A). Three alarm tone frequency (siren, alternating, sweeping). Stainless steel fixings. High impact UL94 Housing. IP66. GOST-R Approved.

GPH1SEDC024G
(3645)

E2S  GPH1SEDC024G

E2S GPH1 Surface Mount Alarm Horn-Buzzer 105dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66. UL and cULs Approved.

GPH2FEDC024G
(3646)

E2S  GPH2FEDC024G

E2S GPH2 Flush Mount Alarm Horn-Buzzer 105dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 24VDC, 115VAC or 230VAC Versions. IP54. UL and cULs Approved.

B300SND030G
(3572)

E2S  B300SND030G

E2S B300SND Compact Signalling Horn 98dB(A). Buzzer type sound and two alarm sounds. Surface Mount. Stainless steel fixings. 12-30VAC/DC or 40-260VAC/DC Versions. IP65.

GPH4FEDC024G
(4441)

E2S  GPH4FEDC024G

E2S GPH4 Flush Mount Alarm Horn-Buzzer 110dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 10-30VDC/AC or 40-260VDC/AC Versions. IP66. UL and cULs Approved.

GPH3SEDC024G
(3647)

E2S  GPH3SEDC024G

E2S GPH3 Surface Mount Alarm Horn-Buzzer 110dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 10-30VDC/AC or 40-260VDC/AC Versions. IP66. UL and cULs Approved.

B400SND030G
(3580)

E2S  B400SND030G

E2S B400SND Compact Signalling Horn 110dB(A). Buzzer type sound and two alarm sounds. Surface Mount. Stainless steel fixings. 10-30VAC/DC or 40-260VAC/DC Versions. IP65.

H110T030G
(3593)

E2S  H110T030G

E2S H110T signalling Horn with Trumpet 110dB(A). With very high output signal to generate a traditional 'buzzer' warning or two further alarm sounds. Surface Mount. Volume control and Stainless Steel fixings. 10-30VAC/DC or 40-260VAC/DC Versions. IP65. GOST-R Approved.

A105NDC_24R
(3271)

E2S  A105NDC24R

E2S A105N high output Alarm Sounder 112dB(A). Low current consumption and high SPL. 24VAC, 115VAC, 230VAC, 24V, 48V or 100V Versions. Stainless steel fixings. Programmable version available. IP66. VdS, GOST-R and MED Approved. UL version available.

IS-MA1-R
(3689)

E2S  IS-MA1-R

E2S IS-mA1 IS-minialarm compact Alarm Sounder 100dB(A). 16-28VDC. Stainless Steel fixings. IP65. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class I Div 1 and Class I Zone 0.

A105NAXDC024R-UL
(3273)

E2S  A105NAXDC024R-UL

E2S A105NAX Appello X User Recordable Alarm Sounder 102dB(A). Low current consumption. 10-30VDC or 90-250VAC Versions. Robust fire retardant Type 4/4X/3R/13, IP66 housing. UL approved.

Page: 1 | 2 | 3 | 4 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.