Det-tronics FlexVu UD10 Explosion-Proof Universal LCD Backlit Display Unit. 24 VDC. Includes 4–20 mA output with HART, relay contacts, and Modbus RS485. Eventm fault and alarm logs. FM, CSA, ATEX, IECEx and SIL 2 certified for Class I Div 1 and Div 2, Zone 1 and Zone 2.

UD10S5N28W2   
Please Email us your request for quote   

Material
Threads
Model

   In Stock  ]

Standard configurations typically available in In Stock:
UD10A5M25T2
8 Variants of base SKU
DESCRIPTION

The FlexVu ® Model UD10 is recommended for applications that require a gas detector with digital readout of detected gas levels as well as analog 4–20 mA output with HART, relay contacts, and Modbus RS485. The UD10 is designed for use with Det‑Tronics gas detectors such as GT3000, PIR9400, PIRECL, PIRECL CO 2 , C706x*, CTX10/CGS, CGS**, ATX10/AV10, PIRDUCT, or LS2000, as well as generic linear 4–20 mA sensors. The display unit is designed and approved as a “stand alone” device and performs all the functions of a gas controller.

Gas concentration and unit of measurement are indicated on a digital display. The display unit provides a linear isolated/non-isolated 4–20 mA DC output signal (with HART) that corresponds to the detected gas concentration.

All electronics are enclosed in an explosion-proof aluminum or stainless steel housing. The display unit is used with a single detector that may be either coupled directly to the UD10, or remotely located using a sensor termination box. The UD10 features non-intrusive calibration. A magnet is used to perform calibration as well as to navigate the UD10’s internal menu.

The UD10 can be used with various 4–20 mA gas detection devices, with or without HART. The unit provides display, output, and control capabilities for the gas detector.

The UD10 utilizes the following I/O:

  • Signal Inputs: 4–20 mA loop from the sensing device
  • User Inputs: Magnetic switches (4) on the display panel HART communication
  • Signal Outputs: 4–20 mA output loop with HART, Modbus RS485, Three alarm relays and one fault relay
  • Visible Outputs: Backlit LCD display, ART slave interface via HART Communicator
FEATURES AND BENEFITS
  • Universal design supports multiple Det-Tronics sensors or generic linear 4–20 mA sensors
  • Local digital LCD display continuously indicates gas level, gas type, and units measured
  • Backlit and heated display
  • Non-intrusive calibration quickly performed by one person
  • Rugged construction approved for use in classified hazardous areas
  • Linear isolated/non-isolated 4–20 mA output with HART
  • Non-intrusive menu allows device configuration without de‑classifying the hazardous area
  • Internal magnetic switches provide a non‑intrusive user interface
  • Smart capabilities with access to sensor information and measurement range
  • Event logs: Calibration with date and time stamp
  • Fault logs: Detector fault, Low power, and General fault
  • Alarm logs: High gas alarm, Low gas alarm, and Aux alarm
  • SIL2 models certified to IEC61508 by exida ®

SPECIFICATIONS
Operating Voltage 24 Vdc nominal, operating range is 18 to 30 Vdc.
Operating Power Standard model, with heater and backlight off:
No alarm: 1.5 watts @ 24 Vdc.
Alarm: 3 watts @ 24 Vdc (20 mA current output and all 3 alarm relays energized).
Backlight on: 0.5 watt additional.
Heater on: 3.5 watts additional.
CGS model: Add 4 watts with CGS interface board and CGS sensor installed.
Maximum power in alarm, with heater and backlight on:
7 watts @ 30 Vdc (Standard model)
11 watts @ 30 Vdc (CGS model)
NOTES:
– Heater turns on when the internal temperature drops below –10°C. Heater function can be disabled to save power.
– Appropriate relays will be activated when a fault or alarm occurs.
Current Output Linear isolated 4–20 mA output with HART.
Maximum loop resistance 600 ohms at 18 to 30 Vdc.
Relay Contacts Three Alarm Relays:
Form C, 5 amperes at 30 Vdc.
Selectable energized/de-energized.
Selectable latching/non‑latching.
One Fault Relay:
Form C, 5 amperes at 30 Vdc.
Normally energized for no fault condition with power FM applied.
Operating Temperature –55°C to +75°C.
Storage Temperature –55°C to +75°C.
Humidity Range 5 to 95% RH (Det-Tronics verified).
Wiring Terminals 14 to 18 AWG, 2.5-0.75 mm 2 wire can be used.
Conduit Entries 3/4" NPT or M25.
Enclosure Material Epoxy coated aluminum or 316 stainless steel.
Shipping Weight Aluminum: 4.15 pounds (1.88 kilograms).
Stainless Steel: 10.5 pounds (4.76 kilograms).
Warranty Find warranty information by clicking on the Terms and Conditions section of the Det-Tronics Resources page: https://www.det-tronics.com/resourcetypes
Electro-Magnetic Compatibility EMC Directive 2014/30/EUM
EN 50270:2015M
EN 61000-6-2:2005M
EN 61000-6-4:2007
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531200020

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> DET-TRONICS :    26 Items found.
010274-003
(7257)

DET-TRONICS  010274-003

Det-tronics GT3000 Certified Calibration Kit for Hydrogen Sulfide (H2S) 0-10 to 0-50ppm. Includes sturdy carrying case containing two cylinders of Class 2.2 non-flammable, non-toxic compressed gas, a 1 liter/minute regulator and pressure indicator, 3-foot tube and GT3000 Calibration Cup.

010569-001
(7247)

DET-TRONICS  010569-001

Det-tronics 010569-001 UD10 Display Module. Relay / 4-20 mA Output.



 
(7434)

DET-TRONICS  012287-002

Det-tronics 012287-002 LS2000 Alignment Tool



 
010970-004
(7248)

DET-TRONICS  010970-004

Det-tronics 010970-004 UPGRADE KIT UD10S5N25T2. Allows field conversion of a Digital Communication Unit (DCU) to a FlexVu UD10 Universal Display. Adds relay, 4-20 mA, RS485 and HART outputs. FM, CSA, ATEX, IECEx and SIL 2 Approvals.



 
009174-013
(7430)

DET-TRONICS  009174-013

Det-tronics 009174-013 EQ3730 8 Channel Enhanced Discrete Input/Output Module (EDIO) with DIN Rail mounting. FM, CSA, ATEX, IECEx and SIL 2 approvals.



 
EQ3001PCSW-C
(7433)

DET-TRONICS  EQ3001PCSW-C

Det-tronics EQ3001 Eagle Quantum Premier Controller for up to 246 Nodes. Includes 3 RS-232, 2 RS-485 ports and 8 Programmable Relay Outputs. Modbus RTU, Modbus TCP/IP or Allen Bradley protocols. FM, IEC, SIL 2 approvals.



 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.