SIMPLEX TYCO   4098-9756

SKU# (7075)
SIMPLEX TYCO 4098-9756
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Simplex Tyco 4098-9756 Addressable Duct Sensor Housing with TrueAlarm Photoelectric Smoke Sensor. Includes relay, supervised output for multiple remote relays and 2 diagnostic LEDs. IDNet and MAPNET II communications. UL listed (requires separate 24 VDC fire alarm power).

RELAYS   UL

Please Email us your request for quote   

   In Stock  ]
Features Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features:
  • Individual sensor information processed by the host control panel to determine sensor status
  • Digital transmission of analog sensor values via IDNet or MAPNET II, 2-wire communications
  • Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation
Model 4098-9756:
  • Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay
  • Relay output is under panel control
  • At the panel, relay output can be activated manually or in response to a separate alarm or other input
General features:
  • UL listed to Standard 268A
  • Clear cover allows visual inspection
  • Test ports provide functional smoke testing access with cover in place
  • Mounts to rectangular ducts or round ducts; minimum size is 8” (203 mm) square or 18” (457 mm) diameter
  • Magnetic test feature for alarm initiation at housing
  • Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032)
Diagnostic LEDs (on interface board):
  • Red Alarm/Trouble LED for sensor status and communications polling display
  • Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only)
Sampling tubes (ordered separately):
  • Available in multiple lengths to match duct size
  • Installed and serviced with housing in place
Remote module options (ordered separately):
  • Remote red status/alarm LED (2098-9808)
  • Remote test station with LED (2098-9806)
  • 4098-9843 remote relays (refer to page 2 for details)
Introduction

Operation. Simplex ® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing.

TrueAlarm Sensor Operation

Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor’s present value against its average.

Intelligent Data Evaluation. Monitoring each photoelectric sensor’s average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down.

Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires.

Sensor Status LED. Each sensor housing’s red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing’s status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.)

Photoelectric Sensing

TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing.

Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel.

Specifications
Air Velocity Range (linear ft/min)300 to 4000 ft/min (91 to 1220 m/min)
Sensor Sensitivity Range0.2% to 3.7% per foot of obscuration, selectable at host control panel
UL Listed Temperature Range32° F to 100° F (0° C to 38° C)
Operating Temperature Range32° F to 122° F (0° C to 50° C)
Storage Temperature Range0° F to 140° F (-18° C to 60° C)
Humidity Range10% to 95% RH, non-condensing
Wiring ConnectionsTerminal blocks, 18 to 12 AWG (0.82 mm 2 to 3.31 mm 2 )
Housing Color and MaterialBlack ABS base with clear polycarbonate cover
Sampling and Exhaust Tube MaterialBlack CPVC, custom extrusion; sampling tubes are pre-drilled
Remote Alarm LED Current1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806)
Test Station Keyswitch Current3.3 mA, no impact to 24 VDC alarm current (2098-9806)
Remote Alarm LED and Test Station Distance250 ft (76 m) maximum
Data CommunicationsIDNet or MAPNET II communications, auto-select, one address per housing; provides operating power to model 4098-9755
Input Voltage18-32 VDC (24 VDC nominal)
Standby Current3 mA @ 24 VDC
Alarm Current15 mA @ 24 VDC; add 15 mA for each 4098-9843 relay
Supervised Remote Relay Control OutputFor use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 k, 1/2 W end-of-line resistor
Export Info
Made inMexico
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    23 Items found.
FCO-951
(3502)

NOTIFIER  FCO-951

Notifier IntelliQuad PLUS FCO-951 Advanced Multi-Criteria Fire/CO Detector with four unique sensing elements: Carbon Monoxide (CO) electrochemical sensor, Infrared (IR) sensing measure, Photo-electric smoke detection and Thermal detection. UL listed. *** replaces FSC-851 ***



 
FSV-951R
(3229)

NOTIFIER  FSV-951R

Notifier FSV-951R Series Very Intelligent Plug-in Early Warning (VIEW) Laser Smoke Detector. 0.03% to 1.00% (CLIP) or 0.02% to 2.00% (other) sensivity. With FlashScan and CLIP protocol systems. Advanced laser light source and 360° viewing angle. Optional relay, isolator and sounder bases. UL and MEA listed. FM, CSFM, BSMI and CCCF Approved. (replaces FSL-751)

FS-OSI-RI
(6933)

NOTIFIER  FS-OSI-RI

Notifier FS-OSI-RI Intelligent Addressable Single-ended Reflective Imaging Beam Smoke Detector suited for large open areas with high ceilings. 24 VDC. 12° field of view. Status LED indicators. UL and FM approved.



 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.