Simplex Tyco 4098-9757 | Intelligent | Smoke | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

SIMPLEX TYCO   4098-9757

SKU# (7073)



SIMPLEX TYCO 4098-9757
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Simplex Tyco 4098-9757 QuickConnect2 TrueAlarm Analog Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet communications. Ceiling or wall mounting. NEMA 1. UL Approved.

UL

4098-9757   
Please Email us your request for quote   

Base
Required base

   2 Days  ]
Model 4098-9757 QuickConnect2 sensor design provides:
  • TrueAlarm photoelectric analog sensing and IDNet two-wire addressable communications combined into one assembly
  • Quick and easy connection to a 4098-9788 base (required, ordered separately)
  • Operation for ceiling or wall mounting
  • Operation for use with Simplex ® models 4007ES, 4010, 4010ES, 4100ES with IDNet 2 and IDNet 2+2 Modules, and 4100ES/4100U Fire Alarm Control Panels with IDNet Module 4100-3106
  • UL listed to Standard 268
QuickConnect2 sensors communicate to the control panel to provide the following TrueAlert analog sensing operation features:
  • Smoke sensitivity that is accurately maintained at the selected level (determined by the control panel)
  • 4007ES, 4010ES, and compatible 4100ES/4100U Series control panels provide seven levels of sensitivity from 0.2% to 3.7%/ft of obscuration (refer to page 2 for application details)
  • 4010 Series control panels provide three levels of sensitivity of 2.5, 3.0, or 3.7%/ft obscuration
  • Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements
  • Automatic environmental compensation
  • Automatic, once per minute individual sensor calibration check verifies sensor integrity
  • Ability to display and print detailed sensor information in plain English language
  • Tracking of excessive dirt accumulation
4098-9788 base provides stationary wiring terminals and quick snap-in sensor connections:
  • Mounting is on a 4” square, 4” octagonal, or single gang box (supplied separately)
  • 4098-9832 Adapter Plate is available for retrofit and certain mounting methods (refer to page 2)
Functional and architecturally styled chamber enclosure details:
  • Louvered design enhances smoke capture by directing flow to chamber
  • Entrance areas are minimally visible when ceiling mounted
  • Chamber is easily accessible for cleaning
  • Designed for EMI compatibility
  • Internal magnetic test feature that activates alarm
Integral red LED (with red lens) indicates:
  • Power-on when pulsing, Alarm or Trouble when steady on (a remote LED is not supported)
  • Refer to data sheet S4098-0019 for sensor bases that support remote LED connections and additional TrueAlarm analog detection features

For applications that only require basic TrueAlarm features, the 4098-9757 QuickConnect2 sensor provides addressable analog sensing in a cost-effective compact package. The control panel monitors and maintains the selected sensitivity of the 4098-9757 as well as providing automatic compensation for environmental conditions such as dust, dirt, and component degradation, and TrueAlarm data capture for each sensor.

QuickConnect2 Mounting. Wiring connections are made to a 4098-9788 base which provides a secure and quick connection for the 4098-9757 sensor. Sensor and communications electronics are contained in the 4098-9757 sensor assembly.

Sensor Alarm and Trouble LED Indication. The control panel also determines when individual sensors need cleaning. Dirty sensors, or other sensor troubles, will automatically be annunciated at the control panel and that sensor’s LED will light steadily. In an alarm condition, the alarmed sensor’s LED will light steadily. (LED operation is controlled by the panel. During system alarm, a sensor LED that was lit to indicate trouble will return to pulsing to conserve communications power as long as it is not in alarm.)

Sensor Locations

Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, spacing of 30 ft (9.1 m) may be used as a guide.

For detailed installation information, refer to 574-709, 4098 Detectors, Sensors, and Bases Application Manual. For mounting base 4098-9788 installation instructions, defer to 574-706, 4098 Smoke/Heat Base Installation Instructions.

Specifications
Power and CommunicationsIDNet communications, auto-selected, 1 address per base
Address AllocationOne address per sensor
IDNet Channel CapabilityUp to 250 sensors/devices per channel
IDNet Connections on 4098-9788 BaseScrew terminals for in/out wiring and shield continuity connection, 18 to 14 AWG (0.82 to 2.08 mm 2 )
Sensitivitywith 4010: Panel selectable as 2.5, 3.0, or 3.7%/ft obscuration
with 4007ES, 4010ES, 4100ES with IDNet 2 or IDNet 2+2 Modules, or 4100ES/4100U with 4100-3106 Module: Panel selectable from 0.2 to 3.7%/ft obscuration; standard sensitivities are 1.5%, 2.0%, 2.5%, and 3.7%; sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas
Note: For detailed application information including sensitivity selection, refer to Installation Instructions 574-709
Air Velocity Range0-2,000 ft/min (0-610 m/min)
UL Listed Temperature Range32° to 100° F (0° to 38° C)
Operating Temperature Range32° to 122° F (0° to 50° C)
Storage Temperature Range0° to 140° F (-18° to 60° C)
Humidity Range10% to 95% RH from 32° to 122° F (0° to 50° C), non-condensing
ColorFrost White
DimensionsRefer to mounting illustrations on page 3
Export Info
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    22 Items found.
4098-9756
(7075)

SIMPLEX TYCO  4098-9756

Simplex Tyco 4098-9756 Addressable Duct Sensor Housing with TrueAlarm Photoelectric Smoke Sensor. Includes relay, supervised output for multiple remote relays and 2 diagnostic LEDs. IDNet and MAPNET II communications. UL listed (requires separate 24 VDC fire alarm power).



 
FS-OSI-RI
(6933)

NOTIFIER  FS-OSI-RI

Notifier FS-OSI-RI Intelligent Addressable Single-ended Reflective Imaging Beam Smoke Detector suited for large open areas with high ceilings. 24 VDC. 12° field of view. Status LED indicators. UL and FM approved.



 