Notifier SPCWL Indoor Selectable-Output Speaker for Ceiling Applications (520 Hz). 12- or 24-volt operation. UL, ULC, FM and CSFM approved.

Please Email us your request for quote   

   4 Weeks  ]
General

The L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate. The installer can pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components.

These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for both wall and ceiling speaker strobes.

The low total harmonic distortion of the SP speaker offers high fidelity sound output while still offering high volume sound out- put for use in high ambient noise applications.

L-SERIES MAKES INSTALLATION EASY
  • Attach a universal mounting plate to a 4" × 4" × 2 1 / 8 " back box. Flush-mount applications do not require an extension ring.
  • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate.
  • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw.
Features
  • Plug-in design and protective cover reduce ground faults.
  • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation.
  • No extension ring required.
  • Field selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177.
  • Automatic selection of 12- or 24-volt operation at 15 and 30 candela.
  • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts).
  • Speakers offer high fidelity and high volume sound output.
  • UL 464 (520 Hz) listed and complies with NFPA 72 requirements for low frequency with compatible fire alarm control panel.
  • Compatible with System Sensor synchronization protocol.
  • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products.
  • Tamper-resistant construction.
  • Updated modern aesthetics.
Architectural/Engineering Specifications

General. L-Series speaker and speaker strobes shall mount to a 4" × 4" × 2 1 / 8 " back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, 177.

Speaker. The speaker shall be a System Sensor L-Series model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches.

Agency Listings and Approvals

The listings and approvals below apply to L-series devices. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL-Listed:
    S4048 Plain Speaker Strobes (Ceiling)
    S4048 Spanish-labeled Speaker Strobes (Ceiling)
    S4048 Speaker Strobe ALERT devices
  • UL/ULC-Listed:
    S4048 Speakers (Ceiling)
    S4048 Speaker Strobes (Ceiling)
  • FM Approved (All except ALERT models)
  • CSFM Listed: 7320-1653:0505

Physical Specifications
Standard Operating Temperature32°F to 120°F (0°C to 49°C).
Humidity Range10 to 93% non-condensing.
Dimensions, Ceiling-MountSPC Speaker: Diameter 6.8 in, 173 mm. Depth: 1.0 in, 25 mm.
SPC Speaker with Surface Mount Back Box: Diameter: 6.9 in, 176 mm. Depth: 3.5 in, 89 mm.
Electrical/Operating Specifications
Nominal Voltage (speakers)25 Volts or 70.7 Volts (nominal).
Maximum Supervisory Voltage (speakers)50 VDC.
Strobe Flash Rate1 flash per second.
Nominal Voltage (strobes)Regulated 12 DC or regulated 24 DC/FWR (full wave rectified).
Operating Voltage Range (includes fire alarm panels with built in sync)8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal).
Operating Voltage with MDL3 Sync Module8.5 V to 17.5 V (12 V nominal) or 16.5 V to 33 V (24 V nominal).
Frequency Range400 to 4,000 Hz. 520Hz capable with compatible fire alarm control panel.
Power¼, ½, 1, 2 watts.

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NOTIFIER :    42 Items found.
HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.