Notifier Xp6-r | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   XP6-R

SKU# (6930)
NOTIFIER XP6-R
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier by Honeywell XP6-R(A) Six Relay Control Module with Form-C Relays. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.

Please Email us your request for quote   

   4 Weeks  ]
General

NOTIFIER’s XP6-R six-relay control module provides an intelligent fire alarm system with six Form-C relays.

The first module is addressed from 01 to 154 while the remaining modules are automatically assigned to the next five higher addresses. Provisions are included for disabling a maximum of three unused modules. A single isolated set of dry relay contacts is provided for each module address, which is capable of being wired for either a normally-open or normally-closed operation. The module allows the control panel to switch these contacts on command. No supervision is provided for the controlled circuit.

Each XP6-R module has panel-controlled green LED indica- tors. The panel can cause the LEDs to blink, latch on, or latch off.

Features
  • Six addressable Form-C relay contacts
  • Removable 12 AWG (3.25 mm²) to 18 AWG (0.9 mm²) plug-in terminal blocks
  • Status indicators for each point
  • Unused addresses may be disabled
  • Rotary address switches
  • FlashScan® or CLIP operation
  • Mount one or two modules in a BB-XP cabinet (optional)
  • Mount up to six modules on a CHS-6 chassis in a CAB-3 Series, CAB-4 Series, EQ Series, or BB-25 cabinet (optional)
  • Mounting hardware included
Agency Listings and Approvals

These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S635
  • ULC Listed: S635 (XP6-RA).
  • MEA Listed: 368-01-E
  • CSFM: 7300-0028:0219
  • Maryland State Fire Marshal: Permit # 2106
  • FM Approved: (Light Protective Signaling Only)

Specifications
Standby current1.45 mA (SLC current draw with all addresses used; if some addresses are disabled, the standby current decreases)
Alarm current32 mA (assumes all six relays have been switched once and all six LEDs solid ON)
Temperature range32°F to 120°F (0°C to 49°C)
Humidity10% to 93% non-condensing
Dimensions6.8" (17.27 cm) high x 5.8" (14.73 cm) wide x 1.0" (2.54 cm) deep
Shipping weight1.1 lb. (0.5 kg) including packaging
Mounting optionsCHS-6 chassis, BB-25 cabinet, BB-XP cabinet, CAB-3 Series (see DN-3549) cabinet, CAB-4 Series (see DN-6857) cabinet, or EQ Series (see DN-60229) cabi- net
Wire gauge12 AWG (3.25 mm²) to 18 AWG (0.9 mm²)
Maximum SLC wiring resistance:40 or 50 ohms, panel dependent
Relay current30 mA/relay pulse (15.6 ms pulse duration), pulse under panel control
Relay contact ratings30 VDC; 70.7 VAC
Current ratings3.0 A @ 30 VDC maximum, resistive, non-coded.
2.0 A @ 30 VDC maximum, resistive, coded.
1.0 A @ 30 VDC maximum, inductive (L/R = 2 ms), coded.
0.5 A @ 30 VDC maximum, inductive (L/R = 5 ms), coded.
0.9 A @ 110 VDC maximum, resistive, non-coded.
0.9 A @ 125 VAC maximum, resistive, non-coded.
0.7 A @ 70.7 VAC maximum, inductive (PF = 0.35), non-coded.
0.3 A @ 125 VAC maximum, inductive (PF = 0.35), non-coded.
1.5 A @25 VAC maximum, inductive (PF = 0.35), non-coded.
2.0 A @25 VAC maximum, inductive (PF = 0.35), non-coded.

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NOTIFIER :    42 Items found.
MMF-300
(7242)

NOTIFIER  MMF-300

Notifier MMF-300 Addressable Monitor Module for supervising circuits of dry-contact input devices. Powered by two-wire SLC loop. 15-32 VDC. UL and FM listed.



 
RTS151KEY
(7241)

NOTIFIER  RTS151KEY

Notifier RTS151KEY automatic remote test station for duct smoke detectors. Includes key and status indicator.



 
MMF-301
(7238)

NOTIFIER  MMF-301

Notifier MMF-301 Addressable Mini-Monitor Module for use in intelligent, two-wire using rotary switches. 15-32 VDC.



 
CRF-300
(7236)

NOTIFIER  CRF-300

Notifier CRF-300 Addressable Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM and MEA Approved.



 
CMF-300
(7243)

NOTIFIER  CMF-300

Notifier CMF-300 Addressable Control Module for providing intelligent control panels a circuit for notification. 15-32 VDC. ULC listed.



 
B300-6
(7063)

NOTIFIER  B300-6

Notifier B300-6 Standard 6” Intelligent Base

SMB500-WH
(4022)

NOTIFIER  SMB500-WH

Notifier System Sensor Surface Mount Box



 
SB-10
(6935)

NOTIFIER  SB-10

Notifier SB-10 (Metal) or SB-I/O (Plastic) Surface Backbox for Notifier NBG-10 or NBG-12 pull stations.

B501-WH
(7067)

NOTIFIER  B501-WH

Notifier B501 4” standard European flangeless mounting base. UL/ULC listed.

SPCWL
(7068)

NOTIFIER  SPCWL

Notifier SPCWL Indoor Selectable-Output Speaker for Ceiling Applications (520 Hz). 12- or 24-volt operation. UL, ULC, FM and CSFM approved.



 
FMM-1
(3695)

NOTIFIER  FMM-1

Notifier FMM-1/FMM-101 Series Monitor Module for supervised dry-contact input devices or monitor and power two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.

HWL-LF
(7065)

NOTIFIER  HWL-LF

Notifier HRL-LF or HWL-LF Low frequency wall sounder (520 Hz). Plastic housing. Includes universal mounting plate. NFPA compliance. UL Listed.

B200S-WH
(6928)

NOTIFIER  B200S-WH

Notifier B200S-WH Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. Only compatible with the NFS-320, NFS2-640 and NFS2-3030 operating version with version 15.0 or higher panel firmware.



 
FCM-1
(3236)

NOTIFIER  FCM-1

Notifier FCM-1 Series Addressable Control Module for Notification Appliances (horns, strobes, speakers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
FRM-1
(3694)

NOTIFIER  FRM-1

Notifier FRM-1 Series Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. Two Form-C dry contacts. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
B210LPBP
(4141)

NOTIFIER  B210LPBP

Notifier B210LPBP Flanged Mounting Intelligent Base (10 Pack)



 
FDM-1
(6597)

NOTIFIER  FDM-1

Notifier FDM-1 Series Monitor Module to supervise, monitor and power Style B dry-contact input devices with two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.



 
B200S-LF-WH
(7066)

NOTIFIER  B200S-LF-WH

Notifier BS200S-LF Low Frequency Intelligent, programmable sounder base (520 Hz). Meest NFPA 72.

FCM-1-REL
(4143)

NOTIFIER  FCM-1-REL

Notifier FCM-1-REL(A) Series Releasing Control Module for fire suppresion releasing applications. Reports the panel status as NORMAL, OPEN or SHORT CIRCUIT. Analog communications. FlashScan operation. 15 to 32 VDC. UL, FM and CSFM Approved.



 
BAT-12180-BP
(4140)

NOTIFIER  BAT-12180-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 18 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 