Rc Systems 35001al-0-9029/0010p/l0 | Voc Pid | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

RC SYSTEMS   35001AL-0-9029/0010P/L0

RC SYSTEMS 35001AL-0-9029/0010P/L0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
RC Systems SenSmart 3500 3 wire gas detector for Volatile Organic Compounds VOC 0-40ppm to 0-1000ppm Isobutylene with 'ST-48' smart transmitter with 10.0eV or 10.6eV PID sensor with arctic heater. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

35001AL-0-9029/0010P/L0   
3,662.33

Enclosure Type
Output
Sensor Type
Sensor Range
Splash Guard

 3 Weeks  ]
251 Variants of base SKU / 30 Shown

The SenSmart 3000 3-wire gas detector is built with our reliable ‘ST-48’ smart transmitter, which provides the cutting-edge technology in toxic and combustible gas detection. It’s a universal, easy to use detector that supports dual smart sensor with different types, including electrochemical, Catalytic Bead, Infrared and Photoionization sensors.

FEATURES HIGHLIGHT
  • CSA Certified for Class I, Div 1 Locations
  • Graphic LCD display shows values, units, trend graph, alarm levels
  • Backlit display for better visibility in low light conditions
  • LED indication of alarm status
  • Dual smart sensor capable
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal-gas
  • Power-up and post-calibration delays eliminate false alarms
  • Options for 3x 5A alarm contacts, isolated 4-20mA and MODBUS®
  • Aluminum “AL” XP model wtih Dual Sensor
  • Auto-recognition of Smart Sensors uploads calibration data and more
  • Real-time clock and calendar logs alarms, calibration and power-up events
  • Security mode allows locking of critical parameters
  • Fault supervision circuitry detects failed sensor and transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • Optional HART board available

OEM VERSION OF THE GDS CORP GASMAX II

SPECIFICATIONS
Power SupplyPower Input 10-30VDC at < 6.5 watts with relay board (all relay energized)
DisplayBacklit 64 x 128 pixel LCD with 30-minute trend, bar graph and engineering units display
Channel One InputElectrochemical toxic and oxygen sensors / 4-20ma current input
Channel Two InputCatalytic Bead, Infrared and Photoionization sensor / 4-20mA current input
Standard OutputDual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Optional OutputsDual isolated 4-20mA current source. Max loop Resistance is 650 ohms with nominal 24VDC; (form C , rated 5 amp at 30 VDC or 240 ~VAC RESISTIVE) MODBUS slave ports; 3x programmable alarm relays with 5A capability
TempElectronics -40°C to +60°C
HousingAluminum with epoxy paint standard; Optional #316 stainless steel, Optional Ul94 Poly Black Plastic Enclosure
Dimensions(Aluminum) Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
(Poly) Width 5” (127 mm), Height 7” (178 mm), Depth 4” (101 mm) Shipping weight 3 pounds (2 kg)
CSA ApprovalsCast Aluminum Enclosure:
Explosion-Proof Cl 1 Div 1 Gr ABCD with 10-0247 (includes sinter)
Non-Incendive Cl 1 Div 2 Gr ABCD with 10-0247 or 10-0247IS
UL94 Poly Black Plastic Enclosure:
Non-Incendive Cl 1 Div 2 Gr ABCD
Warranty5 year limited warranty
For sensor warranty see sensor specifications sheet.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
10-0203
(7043)

RC SYSTEMS  10-0203

RC SYSTEMS Sensor calibration cup adaptor for stainless steel / aluminum sensor heads



$95.71 
CYL-90098576
(1580)

PORTAGAS  CYL-90098576

Calibration Gas Iso-Butylene (C4H8) 100 ppm Balance Air, 34 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$103.16 
CYL-10386054
(1295)

PORTAGAS  CYL-10386054

Calibration Gas Iso-Butylene (C4H8) 1000 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10386052
(1294)

PORTAGAS  CYL-10386052

Calibration Gas Iso-Butylene (C4H8) 500 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90301684
(1293)

PORTAGAS  CYL-90301684

Calibration Gas Iso-Butylene (C4H8) 10 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
10-0552
(7028)

RC SYSTEMS  10-0552

Sample Draw Flow Cell Barrel Adapter for RC Systems Gen I and Gen II 10-0247 Sensor heads(Series 1000, 2000, 3000, 5000 and 6000) gas detectors) 1/8" NPT ports (1 inlet 1 outlet). Used with ST-44 and ST-48 Transmitters.



$213.06 
10-9030
(7104)

RC SYSTEMS  10-9030

RC Systems 10-9030/10-9027/10-9028/10-9029/10-9561/10-9562/10-9564/10-9564 Photoionization Detector (PID) Sensor Assembly for Series 1000, 3000, 5000, 6000 Gas Detectors with ST-44 & ST-48 transmitter, Volatile Organic Compounds (VOC) 10.0eV or 10.6eV, 0-40ppm to 0-1000ppm

Configure

$2,453.24 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20mA input channels board.

Configure

$2,820.78 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. UL and CSA approved for Class I, Division 2, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included. Standard SPDT 5A relays for HORN and FAULT, plus 3 programmable alarm relays included. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. Optional 4-20mA inputs.

Configure

$12,179.52 
> VOC PID :    9 Items found.
M011-0004-000
(6337)

MPOWER  M011-0004-000

mPower NEO Photo-ionization Handheld Gas Detector for Volatile Organic Compounds (VOC). Ranges from 1 ppb up to 15,000 ppm. Audible (90dB0), Visual (flashing LEDs) and wireless remote alarms. Built-in wireless modem and pump. Includes Bluetooth Low Energy (BLE) connectivity, Lithium-ion battery and USB Micro charger. Backlight display. Stainless steel housing. IP66/IP67. UL approval for Class I Div 1.

Configure

$2,560.00 
PQN-8136-1/2
(6965)

PROSENSE  PQN-8136-1/2

Prosense PQN-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$2,661.12 
PQD-8136-1/2
(6720)

PROSENSE  PQD-8136-1/2

Prosense PQD-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$2,851.20 
55001AL-0-9027/100P/L0
(7120)

RC SYSTEMS  55001AL-0-9027/100P/L0

RC Systems SenSmart 5500 3-wire gas detector for Volatile Organic Compounds VOC 10.0eV or 10.6eV with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$3,289.61 
TXLLSLBMR-0000
(5956)

ION SCIENCE  TXLLSLBMR-0000

Ion Science Tiger XTL handheld detector for Volatile Organic Compounds (VOCs) with PID sensor (0-5000ppm). 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger LT ***

Configure

$3,724.00 
FAXSXBXX-3000D
(5955)

ION SCIENCE  FAXSXBXX-3000D

Ion Science Falco Fixed Detector for Volatile Organic Compounds (VOCs) in condensing atmospheres and extreme weather. PID sensor with 10.6 eV lamp. Pumped or diffused versions available. Includes Multi-coloured status display and long-life lamp. ATEX, IECEx, UL and CSA approvals.

Configure

$3,822.00 
967-PB5520-010
(6066)

DETCON  967-PB5520-010

Detcon PI-700 Universal Smart Gas Sensor with Photo Ionization Detector (PID) technology for VOC 0-10ppm to 0-5000ppm. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Built-in numeric display. Water-Proof, Corrosion-Proof and Vibration-Proof. NEMA4X. IP66. CSA (Class I Div 1) and ATEX Approvals.

TXXXSLBMP-0005
(5163)

ION SCIENCE  TXXXSLBMP-0005

Ion Science Tiger XT Select PID (photoionization) handheld detector for Volatile Organic Compounds (VOCs) with dynamic range 1ppb to 20000ppm and internal gas table with over 750 compounds. 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger ***

Configure

$6,188.70 
H-D03-0009-000
(4307)

HONEYWELL  H-D03-0009-000

Honeywell RAEGuard 2 PID Photoionization Detector for VOCs (Volatile Organic Compounds), 10.6 eV Lamp only. 10 to 28 VDC. 4-20mA three-wire and RS-485 Modbus outputs. Explosion-proof stainless-steel enclosure. Graphic display. LED light status indicator. IP65. UL approved for Class I Div 1. (Zone 1). ATEX and IECEx also available.

Configure

$7,365.27 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.