Prosense P-6834 | Nitrogen Dioxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

PROSENSE   P-6834

PROSENSE P-6834
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense P-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

P-6834
900.90

Relays
IP66 Adaptor
No calibration port

   3 Weeks  ]


Trustworthy Certification

PROSENSE "P" Series fixed gas detectors are certified with ATEX/IECEx.

Ex-proof Safety

The continuous measurement of toxic and explosive gases is done safely in hazardous areas thanks to the ex-proof housing.

Robust and Durable

SS316 stainless steel sensor head performs perfectly under harsh environmental conditions with the IP65 protection class.

Accurate Readings

Pellistor, Electrochemical, and Infrared sensors undoubtedly provide an accurate and sensitive measurement.

Ready to Operate

4-20mA Analog and Modbus RS485 RTU outputs are provided onboard to operate properly without any additional setup.

Easy Maintenance

P Series detectors allow sensor replacement with pre-calibrated sensor head thanks to the Procell technology.

Automatic Calibration

Detector calibration can be done automatically via preset values recorded in detector software once calibration requirements are provided.

Pellistor-Saver Mode

Detectors power off sensor in high gas concentration in order to properly secure the operational lifetime of Pellistor sensor.

Auto Analog Signal Monitoring

P Series detectors carefully check the analog output signal level continuously to match the measurement level before promptly transferred to the panel. P Series adjust the signal level in case of any deviation and generate fault signal when adjustment fails.

Universal Communication Protocols

  • 4-20mA Analog and Modbus RS485 RTU outputs are simple to operate efficiently.
  • P Series open-source Modbus codes support successful integration to SCADA systems.
  • P-3R+ relay module can be properly integrated into P Series detectors for extra operations.

Zero Suppression

Adjusting, the detector will show a certain measurement level as 0 (zero) to avoid unnecessary concerns.

Fail-Safe Technology Alarming

Alarm 1 and Alarm 2 relays are easy to set to default LEL, ppm, VOL levels. The fault relay output properly indicates fault status.

Continuous Self-Test

The detectors check itself continuously if it operates perfectly or not and indicates a fault in case of any failure.

Maintenance via Software

Prosense provides software to maintain your active system easily and calibrate the gas detectors properly via computer.

Applications
  • Process Industry
  • Water Treatment
  • Chemical Industry
  • Food and Medicine Facilities
  • Metal Industry
  • Gas Distribution Stations
  • Laboratories

Specifications P-XY34
Sensor Technology Electrochemical
Output Signal 44-20mA and Modbus RS485 RTU
Sensor Warm-Up Time 60sec
Response Time(T90) <30sec*
Accuracy %±1
Operating Temperature -40°C ~ +70°C
Humidity 5 ~ 95%RH
Input Min 10VDC - Max 32VDC - Nominal 24VDC
Power Consumption Max. 4W
Optional Relay Outputs 2 Alarms (Selectable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 2 x 1/2''NPT
IP Rating IP65 / Optional IP66 (Sensor Head)
Junction Box Epoxy Painted Die-Cast Aluminum
Sensor Head 316L Stainless Steel
Dimensions/Weight 183x118,15x88mm / 1420gr
ATEX Marking II 2G Ex db IIC T5/T4 Gb
Hazardous Class Zone 1 or Zone 2
Certificates IMQ 19 ATEX 045 X
IECEx IMQ 18.0009X
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    12 Items found.
PR-KT12
(6978)

PROSENSE  PR-KT12

Prosense 1/2" NPT ATEX Certified Blind Plug for P, PQ and B Series gas detectors



$12.28 
PR-NYY12
(6976)

PROSENSE  PR-NYY12

Prosense 1/2"NPT ATEX Certified Cable Gland for P, PQ and B Series gas detectors



$18.41 
PK-K30T
(6768)

PROSENSE  PK-K30T

Prosense Teflon Calibration cup/cap for P, PE, PQ and B Series gas detectors, tubing entry 4mm diameter tubing. Optional SS316

Configure

$100.98 
PROX-EDU
(7017)

PROSENSE  PROX-EDU

Prosense PDM Software 1-Year license for maintenance, setup, calibration, monitoring and troubleshooting of PQ, P, PC3 series gas detectors. Calibration function is licensed separately, to print calibration reports or certificates directly from the program after calibration.

Configure

$165.00 
HONEYWELL-GFV217-EQUIV
(2293)

PORTAGAS  HONEYWELL-GFV217-EQUIV

Calibration Gas Nitrogen Dixoide (NO2) 10ppm Balance Air Size 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas)

Configure

$252.43 
CYL-10474555
(595)

PORTAGAS  CYL-10474555

Calibration Gas Nitrogen Dioxide (NO2) 25 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$252.43 
P-ASU-2
(6989)

PROSENSE  P-ASU-2

Prosense flow adapter cell for SH30 and SH20 sensor heads used in PQ, P, PE and PC3 series, gas sampling applications. For 6mm OD Tubing made of corrosion-resistant Teflon.



$405.90 
SP-P-TB04
(7037)

PROSENSE  SP-P-TB04

Prosense P Transmitter/Main Board for P series gas detectors



$462.00 
S-DP4
(6764)

PROSENSE  S-DP4

Prosense S-DP4 Gas Detector Controller, Alarm Panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$772.20 
S-DP8
(6765)

PROSENSE  S-DP8

Prosense S-DP8 Gas Detector Controller, Alarm Panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$900.90 
S-DPX064
(7034)

PROSENSE  S-DPX064

Prosense S-DPX064 Gas Detector Controller, Alarm Panel for 64 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$1,801.80 
S-DPX128
(7035)

PROSENSE  S-DPX128

Prosense S-DPX128 Gas Detector Controller, Alarm Panel for 128 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$2,316.60 
> NITROGEN DIOXIDE :    28 Items found.
M001-0011-000
(6004)

MPOWER  M001-0011-000

mPower UNI MP100 Portable Single Gas Detector for detection of Nitrogen Dioxide (NO2) 0-20ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$278.40 
TX1-4
(5967)

INDUSTRIAL SCIENTIFIC  TX1-4

Industrial Scientific Tango TX1 Gas Detector for Nitrogen Dioxide (NO2) 1-150 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

PPS+-NO2
(6814)

PROSENSE  PPS+-NO2

Prosense PPS+-NO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.



$429.00 
PPS-RNO2
(6812)

PROSENSE  PPS-RNO2

Prosense PPS-RNO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



$429.00 
BWS1-D-Y
(6391)

BW  BWS1-D-Y

BW Solo Serviceable Single-gas Detector for Nitrogen dioxide (NO2) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-ND
(2046)

MACURCO  TX-6-ND

Macurco TX-6-ND low voltage Gas Detector, Controller and Transducer for Nitrogen Dioxide (NO2) 0-20 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. power ETL Listed to UL 61010-1.

Configure

$648.99 
TX-12-ND
(3417)

MACURCO  TX-12-ND

MACURCO TX-12-ND line voltage Gas Detector, controller and transducer for Nitrogen Dioxide (NO2) 0-20ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$656.26 
364-455-01-365-732-01
(6156)

DELPHIAN  364-455-01-365-732-01

Delphian GazTell Fixed Point Electrochemical Gas Detector for Nitrogen Dioxide (NO2) 0-100ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-6824
(6809)

PROSENSE  PC3-6824

Prosense PC3-6824 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
SPSTAXN1
(1924)

HONEYWELL  SPSTAXN1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Nitrogen dioxide (NO2) 0-10ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved.

Configure

$993.35 
PQN-6834-1/2
(6957)

PROSENSE  PQN-6834-1/2

Prosense PQN-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
GG-NO2-B-10
(5982)

CALIBRATION TECHNOLOGIES  GG-NO2-B-10

CTI GG-NO2-B Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. NEMA 3RX polycarbonate housing. CSA and UL approved.

Configure

$1,122.00 
2106B1422
(1467)

HONEYWELL  2106B1422

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitrogen Dioxide (NO2) 0-10 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
PQD-6834-1/2
(6745)

PROSENSE  PQD-6834-1/2

Prosense PQD-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109024/007P-L0
(6915)

RC SYSTEMS  1100ALD-109024/007P-L0

RC Systems SenSmart 1100 gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,314.28 
GG-NO2-10-EXP
(5980)

CALIBRATION TECHNOLOGIES  GG-NO2-10-EXP

CTI GG-NO2-EXP Explosion Proof Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,383.00 
41001AL-0-1024/0005P/L0
(7175)

RC SYSTEMS  41001AL-0-1024/0005P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1024/0005P/L0
(7130)

RC SYSTEMS  51001AL-0-1024/0005P/L0

RC Systems SenSmart 5100 3-wire gas detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-640026-010G
(6371)

DETCON  961-640026-010G

Detcon DM-100-NO2 Electrochemical Nitrogen Dioxide (NO2) 0-10ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

SPXCDULNN2
(5107)

HONEYWELL  SPXCDULNN2

Honeywell Sensepoint XCD RTD Gas Detector for Nitrogen dioxide (NO2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 10 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.