Prosense P-6734 | Nitric Oxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

PROSENSE   P-6734

PROSENSE P-6734
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense P-6734 Gas Detector with Electrochemical sensor for Nitric Oxide (NO) with range 0-250ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

P-6734   
823.68

Relays
IP66 Adaptor
No calibration port

   3 Weeks  ]
Trustworthy Certification

PROSENSE "P" Series fixed gas detectors are certified with ATEX/IECEx.

Ex-proof Safety

The continuous measurement of toxic and explosive gases is done safely in hazardous areas thanks to the ex-proof housing.

Robust and Durable

SS316 stainless steel sensor head performs perfectly under harsh environmental conditions with the IP65 protection class.

Accurate Readings

Pellistor, Electrochemical, and Infrared sensors undoubtedly provide an accurate and sensitive measurement.

Ready to Operate

4-20mA Analog and Modbus RS485 RTU outputs are provided onboard to operate properly without any additional setup.

Easy Maintenance

P Series detectors allow sensor replacement with pre-calibrated sensor head thanks to the Procell technology.

Automatic Calibration

Detector calibration can be done automatically via preset values recorded in detector software once calibration requirements are provided.

Pellistor-Saver Mode

Detectors power off sensor in high gas concentration in order to properly secure the operational lifetime of Pellistor sensor.

Auto Analog Signal Monitoring

P Series detectors carefully check the analog output signal level continuously to match the measurement level before promptly transferred to the panel. P Series adjust the signal level in case of any deviation and generate fault signal when adjustment fails.

Universal Communication Protocols

  • 4-20mA Analog and Modbus RS485 RTU outputs are simple to operate efficiently.
  • P Series open-source Modbus codes support successful integration to SCADA systems.
  • P-3R+ relay module can be properly integrated into P Series detectors for extra operations.

Zero Suppression

Adjusting, the detector will show a certain measurement level as 0 (zero) to avoid unnecessary concerns.

Fail-Safe Technology Alarming

Alarm 1 and Alarm 2 relays are easy to set to default LEL, ppm, VOL levels. The fault relay output properly indicates fault status.

Continuous Self-Test

The detectors check itself continuously if it operates perfectly or not and indicates a fault in case of any failure.

Maintenance via Software

Prosense provides software to maintain your active system easily and calibrate the gas detectors properly via computer.

Applications
  • Process Industry
  • Water Treatment
  • Chemical Industry
  • Food and Medicine Facilities
  • Metal Industry
  • Gas Distribution Stations
  • Laboratories

Specifications P-XY34
Sensor Technology Electrochemical
Output Signal 44-20mA and Modbus RS485 RTU
Sensor Warm-Up Time 60sec
Response Time(T90) <30sec*
Accuracy %±1
Operating Temperature -40°C ~ +70°C
Humidity 5 ~ 95%RH
Input Min 10VDC - Max 32VDC - Nominal 24VDC
Power Consumption Max. 4W
Optional Relay Outputs 2 Alarms (Selectable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 2 x 1/2''NPT
IP Rating IP65 / Optional IP66 (Sensor Head)
Junction Box Epoxy Painted Die-Cast Aluminum
Sensor Head 316L Stainless Steel
Dimensions/Weight 183x118,15x88mm / 1420gr
ATEX Marking II 2G Ex db IIC T5/T4 Gb
Hazardous Class Zone 1 or Zone 2
Certificates IMQ 19 ATEX 045 X
IECEx IMQ 18.0009X
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    13 Items found.
PR-KT12
(6978)

PROSENSE  PR-KT12

Prosense 1/2" NPT ATEX Certified Blind Plug for P, PQ and B Series gas detectors



$12.28 
PR-NYY12
(6976)

PROSENSE  PR-NYY12

Prosense 1/2"NPT ATEX Certified Cable Gland for P, PQ and B Series gas detectors



$18.41 
PK-K30T
(6768)

PROSENSE  PK-K30T

Prosense Teflon Calibration cup/cap for P, PE, PQ and B Series gas detectors, tubing entry 4mm diameter tubing. Optional SS316

Configure

$100.98 
PROX-EDU
(7017)

PROSENSE  PROX-EDU

Prosense PDM Software 1-Year license for maintenance, setup, calibration, monitoring and troubleshooting of PQ, P, PC3 series gas detectors. Calibration function is licensed separately, to print calibration reports or certificates directly from the program after calibration.

Configure

$165.00 
MSA-711074-EQUIV
(2359)

PORTAGAS  MSA-711074-EQUIV

Calibration Gas Nitric Oxide 50ppm Balance Nitrogen Size 34 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID neck ring)

Configure

$178.53 
MSA-812144-EQUIV
(2360)

PORTAGAS  MSA-812144-EQUIV

Calibration Gas Nitric Oxide 50ppm Balance Nitrogen Size 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID neck ring)

Configure

$252.43 
CG2-N-50-34
(4282)

BW  CG2-N-50-34

BW Calibration Gas mixture for Nitric Oxide (NO) 50 ppm, 34L aluminum cylinder.

P-ASU-2
(6989)

PROSENSE  P-ASU-2

Prosense flow adapter cell for SH30 and SH20 sensor heads used in PQ, P, PE and PC3 series, gas sampling applications. For 6mm OD Tubing made of corrosion-resistant Teflon.



$405.90 
SP-P-TB04
(7037)

PROSENSE  SP-P-TB04

Prosense P Transmitter/Main Board for P series gas detectors



$462.00 
S-DP4
(6764)

PROSENSE  S-DP4

Prosense S-DP4 Gas Detector Controller, Alarm Panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$772.20 
S-DP8
(6765)

PROSENSE  S-DP8

Prosense S-DP8 Gas Detector Controller, Alarm Panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$900.90 
S-DPX064
(7034)

PROSENSE  S-DPX064

Prosense S-DPX064 Gas Detector Controller, Alarm Panel for 64 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$1,801.80 
S-DPX128
(7035)

PROSENSE  S-DPX128

Prosense S-DPX128 Gas Detector Controller, Alarm Panel for 128 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$2,316.60 
> NITRIC OXIDE :    16 Items found.
M001-0015-000
(6003)

MPOWER  M001-0015-000

mPower UNI MP100 Portable Single Gas Detector for detection of Nitric Oxide (NO) 0-250ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$278.40 
BWS1-N-Y
(6390)

BW  BWS1-N-Y

BW Solo Serviceable Single-gas Detector for Nitric oxide (NO) 0-250 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-6724
(6808)

PROSENSE  PC3-6724

Prosense PC3-6724 Gas Detector with Electrochemical sensor for Nitric Oxide (NO) with range 0-250 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$746.46 
PQN-6734-1/2
(6956)

PROSENSE  PQN-6734-1/2

Prosense PQN-6734 Gas Detector with Electrochemical sensor for Nitric Oxide (NO) with range 0-250ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,003.86 
2106B1418
(1464)

HONEYWELL  2106B1418

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitric Oxide (NO) 0-100 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
PQD-6734-1/2
(6744)

PROSENSE  PQD-6734-1/2

Prosense PQD-6734 Gas Detector with Electrochemical sensor for Nitric Oxide (NO) with range 0-250ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
41001AL-0-1023/0025P/L0
(7173)

RC SYSTEMS  41001AL-0-1023/0025P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
961-940026-100G
(6370)

DETCON  961-940026-100G

Detcon DM-100-NO Electrochemical Nitric Oxide (NO) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

51001AL-0-1023/0025P/L0
(7174)

RC SYSTEMS  51001AL-0-1023/0025P/L0

RC Systems SenSmart 5100 3-wire gas detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
2100AL-0-9023/007P/L0
(7140)

RC SYSTEMS  2100AL-0-9023/007P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,789.61 
S3KUL2-XNXXSM1SS
(697)

HONEYWELL  S3KUL2-XNXXSM1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring NITRIC OXIDE (NO) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-100ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,789.84 
SPXCDULND2
(1900)

HONEYWELL  SPXCDULND2

Honeywell Sensepoint XCD RTD Gas Detector for Nitric Oxide (NO) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 100 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
31001AL-0-9023/025P/L0
(5785)

RC SYSTEMS  31001AL-0-9023/025P/L0

RC Systems SenSmart 3100 3 wire gas detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$2,145.28 
967-949490-100
(6095)

DETCON  967-949490-100

Detcon DM-700-NO Electrochemical Smart Nitric Oxide (NO) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSM1SS
(848)

HONEYWELL  XNXUTAENNNNN-XNXXSM1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Nitric oxide (NO) 0-100ppm compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,275.97 
6100AL1-0-1023/0025P
(7011)

RC SYSTEMS  6100AL1-0-1023/0025P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class 1 Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.